Publications by authors named "Martin Weber Kusk"

Objectives: This prospective study tested the diagnostic accuracy, and absolute agreement with MRI of a low-dose CT protocol for left ventricular ejection fraction (LVEF) measurement. Furthermore we assessed its potential for combining it with Chest-Abdomen-Pelvis CT (CAP-CT) for a one-stop examination.

Materials & Methods: Eighty-two patients underwent helical low-dose CT.

View Article and Find Full Text PDF

Background: Measuring left ventricular ejection fraction (LVEF) is important for detecting heart failure, e.g., in treatment with potentially cardiotoxic chemotherapy.

View Article and Find Full Text PDF

Background: Patients with non-specific symptoms or signs of cancer (NSSC) present a challenge as they are a heterogeneous population who are not candidates for fast-track work-up in an organ-specific cancer pre-planned pathway (CPP). Denmark has a cancer pre-planned pathway for this population (NSSC-CPP), but several issues remain unclarified, for example, distribution and significance of symptoms and findings, and choice of imaging.

Aim: To investigate symptoms, cancer diagnoses, and diagnostic yield of computed tomography (CT) and fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-FDG-PET/CT) in patients on NSSC-CPP to improve the overall diagnostic process.

View Article and Find Full Text PDF

To investigate the impact of combining the high-resolution (Hi-res) scan mode with deep learning image reconstruction (DLIR) algorithm in CT. Two phantoms (Catphan600® and Lungman, small, medium, large size) were CT scanned using combinations of Hi-res/standard mode and high-definition (HD)/standard kernels. Images were reconstructed with ASiR-V and three levels of DLIR.

View Article and Find Full Text PDF

Introduction: To investigate how ASiR-V and kVp changes in Computed tomography (CT) affect radiation dose and image quality, when using automatic tube current modulation (ATCM) for different sized phantoms.

Methods: A liver-phantom with two different liver inserts (QRM, Moehrendorf, Germany), with extension rings, representing fat, were additionally applied to the phantom to simulate patients of different sizes (small: 30cm diameter, medium: 35cm and large: 40cm). Abdominal scans were performed on a 256 slice CT scanner (GE Healthcare, Milwaukee, WI, USA), with consistent pitch (0.

View Article and Find Full Text PDF

Aims: The aim of this study was to evaluate the association between coronary computed tomography angiography (CCTA)-derived fractional flow reserve (FFRCT) and recurrent chest pain (CP) at 1-year follow-up in patients with stable angina pectoris (SAP).

Methods And Results: Study of patients (n = 267) with SAP who underwent CCTA and FFRCT testing; 236 (88%) underwent invasive coronary angiography; and 87 (33%) were revascularized. Symptomatic status at 1-year follow-up was gathered by a structured interview.

View Article and Find Full Text PDF

The purpose of this study was to investigate the challenges in comparing digital radiography (DR) systems from different vendors for various combinations of exposure factors in posterior-anterior hand radiographs. Image quality was evaluated for a range of tube voltages and tube current-time products using a technical contrast-detail (CDRAD) phantom and an anthropomorphic hand phantom. 900 technical CDRAD images were analysed providing quality figures of merit (IQFinv) and two experienced reporting radiographers using visual grading analysis (VGA) scored 108 anthropomorphic images.

View Article and Find Full Text PDF

Purpose: To examine the diagnostic accuracy of spectral CT pulmonary angiography (S-CTPA) using ventilation-perfusions lung scintigraphy (V/Q-scan) as a reference standard in the diagnosis of acute or chronic pulmonary embolism (APE/CPE) and chronic thromboembolic pulmonary hypertension (CTEPH).

Methods: PubMed, Embase, Scopus, and Web of Science were searched for the period from 1 Jan 2006 to 7 Feb 2019; eligible studies had > 10 patients over 18 years old, a diagnostic outcome of PE or CTEPH, and used V/Q scan as a reference standard. Bias and applicability were assessed using QUADAS-2 tools.

View Article and Find Full Text PDF

The purpose was to examine if scatter correction software could replace a grid while maintaining image quality and reducing radiation dose for pelvic DR examinations. Grid images was produced with 70 kV and 16mAs. Anthropomorphic- and Contrast Detail RADiography (CDRAD) non-grid images were produced with 60 kV, 80 kV and 90 kV combined with five different mAs and scatter correction software.

View Article and Find Full Text PDF

Background: Generation of multiplanar reformation (MPR) images has become automatic on most modern computed tomography (CT) scanners, potentially increasing the workload of the reporting radiologists. It is not always clear if this increases diagnostic performance in all clinical tasks.

Purpose: To assess detection performance using only coronal multiplanar reformations (MPR) when triaging patients for lung malignancies with CT compared to images in three orthogonal planes, and to evaluate performance comparison of novice and experienced readers.

View Article and Find Full Text PDF