Objective: It is not known how much surfactant must be nebulized to reach a lung dose of phospholipids equivalent to that obtained by the instillation of 200 mg/kg of surfactant. We aimed to assess the feasibility of nebulizing a high-dose of poractant alfa with the eFlow-Neos investigational vibrating-membrane nebulizer in newborn piglets on nasal continuous positive airway pressure (nCPAP) and to determine whether this intervention would yield therapeutic lung doses of phospholipids.
Study Design: Twelve 1-day-old piglets on nCPAP received 600 mg/kg of poractant alfa admixed with technetium-99m via nebulization.
Introduction: The ideal body position during surfactant nebulization is not known.
Objective: The aim of this study was to determine whether body positioning during surfactant nebulization influences surfactant distribution and deposition in the lungs.
Methods: Twenty-four 12- to 36-h-old full-termpiglets (1.
The delivery of nebulized medications to preterm infants during Non-Invasive Ventilation (NIV) remains an unmet clinical need. In this regard, the effective delivery of nebulized surfactant has been particularly investigated in preclinical and clinical studies. In this work, we investigated the feasibility of delivering nebulized surfactant through various commercially available nasal prong types.
View Article and Find Full Text PDFNon-invasive delivery of nebulized surfactant has been a long-pursued goal in neonatology. Our aim was to evaluate the performance of an investigational vibrating-membrane nebulizer in a realistic non-invasive neonatal ventilation circuit with different configurations. Surfactant (aerosols were generated with a nebulizer in a set-up composed of a continuous positive airway pressure (CPAP) generator with a humidifier, a cast of the upper airway of a preterm infant (PrINT), and a breath simulator with a neonatal breathing pattern.
View Article and Find Full Text PDFBackground: Nasal continuous positive airway pressure support (nCPAP) is the standard of care for prematurely born infants at risk of neonatal respiratory distress syndrome (nRDS). However, nasal intermittent positive pressure ventilation (NIPPV) may be an alternative to nCPAP in babies requiring surfactant, and in conjunction with surfactant nebulization, it could theoretically reduce the need for invasive mechanical ventilation. We compared lung deposition of nebulized poractant in newborn piglets supported by nCPAP or NIPPV.
View Article and Find Full Text PDFBackground: The development of endoluminal stents from polymeric materials requires an understanding of the basic mechanical properties of the polymer and the effects of manufacturing and sterilization on those properties.
Methods: Pure poly(L-lactide) (PLLA) and PLLA containing varying amounts of triethylcitrate (TEC) as a plasticizer (5-10-15%) were studied. The specimens were solution-cast and CO2 laser-cut.