Publications by authors named "Martin R Hofmann"

In this paper, the investigation of laser-induced periodic surface structures (LIPSSs) on a polycrystalline diamond substrate using synthetic optical holography (SOH) is demonstrated. While many techniques for LIPSS detection operate with sample contact and/or require preparation or processing of the sample, this novel technique operates entirely non-invasively without any processing of or contact with the LIPSS sample at all. The setup provides holographic amplitude and phase images of the investigated sample with confocally enhanced and diffraction-limited lateral resolution, as well as three-dimensional surface topography images of the periodic structures via phase reconstruction with one single-layer scan only.

View Article and Find Full Text PDF

Purpose: A precise resection of the entire tumor tissue during surgery for brain metastases is essential to reduce local recurrence. Conventional intraoperative imaging techniques all have limitations in detecting tumor remnants. Therefore, there is a need for innovative new imaging methods such as optical coherence tomography (OCT).

View Article and Find Full Text PDF

In this paper, we present a confocal laser scanning holographic microscope for the investigation of buried structures. The multimodal system combines high diffraction limited resolution and high signal-to-noise-ratio with the ability of phase acquisition. The amplitude and phase imaging capabilities of the system are shown on a test target.

View Article and Find Full Text PDF

We present spatially resolved measurements of the below-band-gap carrier-induced absorption and concurrent phase change in a semiconductor with the help of transmission digital holography. The application is demonstrated for a bulk GaAs sample, while the holograms are recorded with a conventional CMOS sensor. We show that the phase information enables spatially resolved monitoring of excess carrier distributions.

View Article and Find Full Text PDF

In this Letter, we report optical pulse generation from a single-section diode gain chip, employed in an external cavity geometry based on the self-mode-locking regime. The gain chip emits light at 1550 nm wavelength range. The external cavity is operated at various repetition rates, ranging from 1 to 2.

View Article and Find Full Text PDF

A big challenge of the 21st century is to cope with the huge amounts of plastic waste on Earth. Especially the oceans are heavily polluted with plastics. To counteract this issue, biological (enzymatic) plastic decomposition is increasingly gaining attention.

View Article and Find Full Text PDF

Androgen deprivation therapy remains the backbone therapy for the treatment of metastatic hormone-sensitive prostate cancer (mHSPC). In recent years, several treatments, including docetaxel, abiraterone + prednisone, enzalutamide, and apalutamide, have each been shown to demonstrate survival benefit when used upfront along with androgen deprivation therapy. However, treatment selection for an individual patient remains a challenge.

View Article and Find Full Text PDF

In this Letter, we investigate the resolution of two-photon polymerization (2PP) with an amplified mode-locked external cavity diode laser with adjustable pulse length and a high repetition rate. The experimental results are analyzed with a newly developed 2PP model. Even with low pulse peak intensity, the produced structural dimensions are comparable to those generated by traditional 2PP laser sources.

View Article and Find Full Text PDF

This paper analyzes the performance of single-shot digital holographic microscopy for rapid characterization of static step-index structures in transparent polymer materials and for online monitoring of the photoinduced polymerization dynamics. The experiments are performed with a modified Mach-Zehnder transmission digital holographic microscope of high stability (phase accuracy of 0.69°) and of high magnification (of ≈90×).

View Article and Find Full Text PDF

Objective: Optical coherence tomography (OCT) is an imaging technique that uses the light-backscattering properties of different tissue types to generate an image. In an earlier feasibility study the authors showed that it can be applied to visualize human peripheral nerves. As a follow-up, this paper focuses on the interpretation of the images obtained.

View Article and Find Full Text PDF

We analyze transducer-matched multipulse excitation as a method for improving of the signal-to-noise ratio (SNR) for diode laser-based photoacoustic systems. We discuss the principle of the technique, its advantages, and potential drawbacks and perform measurements to analyze the obtainable SNR increase. We show in experiment and computationally that a lower boundary estimate of 1.

View Article and Find Full Text PDF

Lasers have both ubiquitous applications and roles as model systems in which non-equilibrium and cooperative phenomena can be elucidated. The introduction of novel concepts in laser operation thus has potential to lead to both new applications and fundamental insights. Spintronics, in which both the spin and the charge of the electron are used, has led to the development of spin-lasers, in which charge-carrier spin and photon spin are exploited.

View Article and Find Full Text PDF

We demonstrate an innovative concept for three-dimensional optical fluence mapping in heterogeneous highly scattering media as, e.g., biomedical tissues.

View Article and Find Full Text PDF

Brain tissue analysis is highly desired in neurosurgery, such as tumor resection. To guarantee best life quality afterward, exact navigation within the brain during the surgery is essential. So far, no method has been established that perfectly fulfills this need.

View Article and Find Full Text PDF

We present a femtosecond laser diode system that is capable of autonomously adjusting itself to compensate for the external dispersion in an arbitrary application. The laser system contains a spatial light modulator inside the cavity which is controlled by an evolutionary algorithm in order to allow for phase and amplitude shaping of the laser emission. The cavity-internal dispersion control is shown to be much more efficient than an external control with a pulse shaper.

View Article and Find Full Text PDF

Patient-reported outcomes (PROs) are essential to assessing the effectiveness of care, and many general-health and disease-specific PROs have been developed. Until recently, data were collected predominantly with pen-and-paper questionnaires. Now, though, there is a potential role for electronic medical records in data collection.

View Article and Find Full Text PDF

A self-optimizing approach to intra-cavity spectral shaping of external cavity mode-locked semiconductor lasers using edge-emitting multi-section diodes is presented. An evolutionary algorithm generates spectrally resolved phase- and amplitude masks that lead to the utilization of a large part of the net gain spectrum for mode-locked operation. Using these masks as a spectral amplitude and phase filter, a bandwidth of the optical intensity spectrum of 3.

View Article and Find Full Text PDF

In this paper, we present a system that allows imaging of cartilage tissue via optical coherence tomography (OCT) during controlled uniaxial unconfined compression of cylindrical osteochondral cores in vitro. We describe the system design and conduct a static and dynamic performance analysis. While reference measurements yield a full scale maximum deviation of 0.

View Article and Find Full Text PDF

In this Letter, we present a new approach to processing data from a standard spectral domain optical coherence tomography (OCT) system using depth filtered digital holography (DFDH). Intensity-based OCT processing has an axial resolution of the order of a few micrometers. When the phase information is used to obtain optical path length differences, subwavelength accuracy can be achieved, but this limits the resolvable step heights to half of the wavelength of the system.

View Article and Find Full Text PDF

We analyze the influence of second and third order intracavity dispersion on a passively mode-locked diode laser by introducing a spatial light modulator (SLM) into the external cavity. The dispersion is optimized for chirped pulses with highest possible spectral bandwidth that can be externally compressed to the sub picosecond range. We demonstrate that the highest spectral bandwidth is achieved for a combination of second and third order dispersion.

View Article and Find Full Text PDF

In this paper we analyze the capability of adaptive lenses to replace mechanical axial scanning in confocal microscopy. The adaptive approach promises to achieve high scan rates in a rather simple implementation. This may open up new applications in biomedical imaging or surface analysis in micro- and nanoelectronics, where currently the axial scan rates and the flexibility at the scan process are the limiting factors.

View Article and Find Full Text PDF

Spectroscopic Optical Coherence Tomography (S-OCT) extracts depth resolved spectra that are inherently available from OCT signals. The back scattered spectra contain useful functional information regarding the sample, since the light is altered by wavelength dependent absorption and scattering caused by chromophores and structures of the sample. Two aspects dominate the performance of S-OCT: (1) the spectral analysis processing method used to obtain the spatially-resolved spectroscopic information and (2) the metrics used to visualize and interpret relevant sample features.

View Article and Find Full Text PDF

We introduce depth-filtered digital holography (DFDH) as a method for quantitative tomographic phase imaging of buried layers in multilayer samples. The procedure is based on the acquisition of multiple holograms for different wavelengths. Analyzing the intensity over wavelength pixel wise and using an inverse Fourier transform leads to a depth-profile of the multilayered sample.

View Article and Find Full Text PDF

We use photorefractive two-wave mixing for coherent amplification of the object beam in digital holographic recording. Both amplitude and phase reconstruction benefit from the prior amplification as they have an increased SNR. We experimentally verify that the amplification process does not affect the phase of the wavefield.

View Article and Find Full Text PDF