IEEE Trans Ultrason Ferroelectr Freq Control
August 2024
A new approach for vascular super-resolution (SR) imaging using the erythrocytes as targets (SUper-Resolution ultrasound imaging of Erythrocytes (SURE) imaging) is described and investigated. SURE imaging does not require fragile contrast agent bubbles, making it possible to use the maximum allowable mechanical index (MI) for ultrasound scanning for an increased penetration depth. A synthetic aperture (SA) ultrasound sequence was employed with 12 virtual sources (VSs) using a 10-MHz GE L8-18i-D linear array hockey stick probe.
View Article and Find Full Text PDFCapacitive micromachined ultrasonic transducers (CMUTs) have a nonlinear relationship between the applied voltage and the emitted signal, which is detrimental to conventional contrast enhanced ultrasound (CEUS) techniques. Instead, a three-pulse amplitude modulation (AM) sequence has been proposed, which is not adversely affected by the nonlinearly emitted harmonics. In this paper, this is shown theoretically, and the performance of the sequence is verified using a 4.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
October 2022
Row-column (RC) arrays have the potential to yield full 3-D ultrasound imaging with a greatly reduced number of elements compared to fully populated arrays. They, however, have several challenges due to their special geometry. This review article summarizes the current literature for RC imaging and demonstrates that full anatomic and functional imaging can attain a high quality using synthetic aperture (SA) sequences and modified delay-and-sum beamforming.
View Article and Find Full Text PDFThis study evaluates the use of 3D printed phantoms for 3D super-resolution ultrasound imaging (SRI) algorithm calibration. The main benefit of the presented method is the ability to do absolute 3D micro-positioning of sub-wavelength sized ultrasound scatterers in a material having a speed of sound comparable to that of tissue. Stereolithography is used for 3D printing soft material calibration micro-phantoms containing eight randomly placed scatterers of nominal size 205 μm × 205 μm × 200 μm.
View Article and Find Full Text PDFDelay-and-sum (DAS) beamforming is unable to identify individual scatterers when their density is so high that their point spread functions overlap. This paper proposes a convolutional neural network (CNN)-based method to detect and localize high-density scatterers, some of which are closer than the resolution limit of delay-and-sum (DAS) beamforming. A CNN was designed to take radio frequency channel data and return non-overlapping Gaussian confidence maps.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
March 2020
A 3-D super-resolution (SR) pipeline based on data from a row-column (RC) array is presented. The 3-MHz RC array contains 62 rows and 62 columns with a half wavelength pitch. A synthetic aperture (SA) pulse inversion sequence with 32 positive and 32 negative row emissions is used for acquiring volumetric data using the SARUS research ultrasound scanner.
View Article and Find Full Text PDF