Cardiovasc Intervent Radiol
November 2024
Purpose: The visualization of peripheral in-stent restenosis using energy-integrating detector CT is challenging due to deficient spatial resolution and artifact formation. This study compares the first clinically available photon-counting detector CT to third-generation dual-source energy-integrating detector CT.
Materials And Methods: Nylon cylinders with central bores (4 mm, 2 mm), mimicking 75% and 95% stenoses, were placed inside seven different 8-mm diameter stents and filled with diluted contrast medium.
Objective: Bridging stentgrafts (BSGs) are one of the primary limiting factors regarding long-term results after fenestrated endovascular aortic repair (fEVAR). This study aims to report for the first time the outcome of a novel BSG called iCover from a national, multicentric retrospective database.
Methods: A cohort of 58 patients received 212 BSGs for the renovisceral arteries in fEVAR.
Objective: To assess the early experience with modified version of simplified bare-wire target vessel (SMART) technique, implying delivery of bridging stent grafts without historically established sheath support, and to compare its outcome to standard endovascular aortic repair procedures with fenestrated/branched devices.
Methods: A retrospective analysis of 102 consecutive patients treated with fenestrated/branched devices from January 2020 to December 2022 was undertaken. The study population was divided into three groups-a sheath group (SG), SMART group, and nonsheath group (NSG).
Eur J Cardiothorac Surg
May 2023
Objectives: Endovascular treatment has been suggested as an alternative for open surgery for type A aortic dissection, but current devices have severe anatomical limitations. This study assesses the computed tomography-based anatomical suitability of currently manufactured stent grafts as well as 2 embodiments of valve-carrying devices.
Methods: In a retrospective single-centre cohort of 200 consecutive ascending/arch operations between 2009 and 2018, a total of 112 patients with type A aortic dissections were identified and evaluated for endovascular candidacy based on the locations of the entries, the landing zone diameters/lengths and the supra-aortic vessel origins according to the anatomical instructions for use criteria of 6 commercially available (tubular, branched or fenestrated) stent grafts.
Purpose: In penetrating aortic ulcers (PAUs), limited data support tubular thoracic endovascular aortic repair (TEVAR) as a viable treatment option. For treatment of more proximal PAUs, hybrid approaches and-more recently-scalloped TEVAR (scTEVAR) have been advocated. Outcomes of scTEVAR specifically for PAUs have not yet been reported.
View Article and Find Full Text PDFObjective: Endovascular aortic repair (EVAR) with fenestrated (F-EVAR) or branched (B-EVAR) endografts represents an indispensable tool of modern patient care in vascular surgery. The purpose of this retrospective study was to evaluate the center's initial experience of F/B-EVAR procedures performed under biplane angiography guidance compared with a historical control group.
Methods: From January 2020 to March 2022, 80 consecutive patients underwent F/B-EVAR under general anesthesia at a single institution.
KRAS is mutated in approximately 25% of cancer patients and first KRAS G12C-specific inhibitors showed promising responses. Pancreatic cancer has the highest frequency of KRAS mutations but the prevailing KRAS G12D mutation is difficult to target. Inhibition of the GTP exchange factor (GEF) SOS1-KRAS interaction impairs oncogenic signaling independently of the specific KRAS mutations.
View Article and Find Full Text PDFAll patients who underwent endovascular aortic repair (EVAR) need a thorough follow-up, at least yearly. Contrast-enhanced ultrasound and computed tomography angiography (CTA) are the most important modalities for detection of endoleaks, whereby CTA allows better differentiation of endoleak type. High pressure endoleaks (type I and III) are an absolute indication for treatment if they do not resolve spontaneously in the short term.
View Article and Find Full Text PDFBackground: Today, complex abdominal aortic pathologies involving the visceral arteries and without an adequate proximal neck can be treated using fenestrated/branched endovascular aortic repair (FEVAR/BEVAR) with similar safety and success rates as infrarenal aortic pathologies treated with tubular EVAR.
Methodical Innovations And Challenges: Fenestrations (if the vessel originates from a nondilated aorta) or branches (if the vessel originates from a dilated aorta) may be used for the visceral arteries. Both types of openings are sealed via bridging stent grafts that connect to the target vessel.
Objective: For thoracic endovascular aortic repair of the arch, branched and fenestrated endografts are available with different limitations regarding anatomy and extent of the pathology. Comparisons are lacking in the literature. The aim of this study was to compare the results of 2 currently commercially available devices for branched thoracic endovascular aortic repair and fenestrated thoracic endovascular aortic repair.
View Article and Find Full Text PDFPurpose: To compare bridging stent graft (BSG) implantation in downward oriented branches in branched endovascular aortic repair (bEVAR), using a commercially available steerable sheath from an exclusively femoral access (TFA) with traditional upper extremity access (UEA).
Methods: In a retrospective cohort study, 7 patients with 19 branches in the TFA cohort received BSG insertion using the Medtronic Heli FX steerable sheath from a femoral access, and 10 patients with 32 branches in the UEA cohort from a brachial approach. Technical success, total intervention time, fluoroscopy time, branch cannulation time, and complication rate were recorded.
Objective: To present a case series of spontaneous structural failure of bridging stentgrafts (BSGs) after branched endovascular aortic repair (bEVAR), as well as their failure types and their detection. While bEVAR is a safe and effective procedure, one main limitation is the reintervention rate associated with the BSGs. Structural failure of BSGs, defined as fabric disruption, stent fracture with leak or complete separation is a major cause for reinterventions and difficult to detect in computed tomography angiography (CTA).
View Article and Find Full Text PDFBackground: The most relevant determinant in scheduling monitoring intervals for abdominal aortic aneurysms (AAAs) is maximum diameter. The aim of the study was to develop a statistical model that takes into account specific characteristics of AAA growth distributions such as between-patient variability as well as within-patient variability across time, and allows probabilistic statements to be made regarding expected AAA growth.
Methods: CT angiography (CTA) data from patients monitored at 6-month intervals with maximum AAA diameters at baseline between 30 and 66 mm were used to develop the model.
KRAS is mutated in approximately 25% of Non-small Cell Lung Cancer (NSCLC) patients and first specific inhibitors showed promising responses that may be improved by concurrent interference with downstream signaling pathways. Cell lines exhibiting KRAS mutations show specific sensitivities to modulators affecting glucose utilization, signal transduction and cell survival. Novel SOS1-directed inhibitors with a broader anticancer coverage such as BAY-293 and BI-3406 inhibit KRAS through the hindrance of SOS1-KRAS interactions.
View Article and Find Full Text PDFIn the absence of suitable molecular markers, non-small cell lung cancer (NSCLC) patients have to be treated with chemotherapy with poor results at advanced stages. Therefore, the activity of the anticancer marine drug fascaplysin was tested against primary NSCLC cell lines established from pleural effusions. Cytotoxicity of the drug or combinations were determined using MTT assays and changes in intracellular phosphorylation by Western blot arrays.
View Article and Find Full Text PDFPurpose: To test a stent-graft specifically designed for the ascending aorta in phantom, cadaver, and clinical application, and to measure deployment accuracy to overcome limitations of existing devices.
Methods: A stent-graft has been designed with support wires to fixate the apices toward the inner curvature, thereby eliminating the forward movement of the proximal end which can happen with circumferential tip capture systems. The device was deployed in three aortic phantoms, and in four cadavers, deployment precision was measured.
Objective: Infection of prosthetic aortic grafts represents a serious complication with high morbidity and mortality. Replacement with autologous material is recommended; however, in its absence, biological material should be favored. In the present retrospective cohort study, we evaluated the short- and midterm results with the use of commercially available prefabricated bovine pericardium grafts (BPGs) used for the management of aortic graft infection or aortic reconstructive surgery in the presence of systemic infection.
View Article and Find Full Text PDFCase Rep Obstet Gynecol
June 2019
Lung cancer during pregnancy represents a rare disease. In this case report, we present a patient at advanced and metastasized stage of signet ring cell carcinoma who presented in the 22 week of gestation.
View Article and Find Full Text PDFObjective: This study retrospectively assessed in-hospital mortality and long-term results of emergency thoracic endovascular aortic repair (TEVAR) for patients with life-threatening acute complicated type B aortic dissection (acTBD).
Methods: Between March 2001 and December 2016, there were 55 patients (40 male; median age, 52 ± 13 years) with an acTBD who were treated with TEVAR for malperfusion (58%), aortic rupture (18%), or persistent untreatable pain with true lumen reduction or rapid aortic diameter enlargement (24%) as a sign of disease progression. The patients were categorized according to clinical appearance into two groups: group A, malperfusion, pending rupture, or rupture; and group B, persistent ongoing pain, rapid enlargement of aortic diameter, or significant changes in the true to false lumen ratio.
Objective: The aim of the study was to follow both the structure- and function-related long-term course of shoulders that had been treated with therapeutic ultrasound for symptomatic calcific tendinitis.
Design: This is a long-term follow-up of 45 shoulders (37 patients) that had been treated for symptomatic calcific tendinitis with either a series of ultrasound or sham ultrasound 10 yrs ago. The main outcome variables were presence of calcium deposits and subacromial impingement on standardized x-ray imaging, shoulder symptoms (Binder score), and function (Constant score).
Background: Self-expanding nitinol stents must be oversized at least by a minimal amount to ensure contact with the vessel wall and prevent migration. Once the stent is deployed it exerts a continuous force upon the vascular wall, termed chronic outward force (COF). Animal studies have found an increased neointimal hyperplasia in stents with high oversizing and thus high COF.
View Article and Find Full Text PDFThe rupture of an extracranial vertebral artery aneurysm has only been rarely described in the literature and treatment options are therefore not standardized. Here we report the successful endovascular repair of a spontaneously ruptured extracranial left vertebral artery aneurysm using Onyx instillation. A 48-year-old woman was transferred to our clinic after having been intubated due to a massive hematoma of the left neck.
View Article and Find Full Text PDFJACC Cardiovasc Interv
July 2016
Objectives: The hypothesis that paclitaxel-eluting balloon angioplasty provides higher 1-year patency rates in femoropopliteal artery in-stent restenosis compared with standard percutaneous transluminal angioplasty (PTA) was tested.
Background: Several trials have demonstrated that paclitaxel-eluting balloon angioplasty reduces late luminal loss in comparison with PTA.
Method: In a prospective, randomized, single-blind, dual-center study, 74 patients with symptomatic peripheral artery disease due to in-stent restenosis were treated with either paclitaxel-based drug-eluting balloon (DEB) angioplasty (n = 35) or standard PTA (n = 39).