Publications by authors named "Marta Doval Minarro"

Air quality management is underpinned by continuous measurements of concentrations of target air pollutants in monitoring stations. Although many approaches for optimizing the number and location of air quality monitoring stations are described in the literature, these are usually focused on dense networks. However, there are small and medium-size urban areas that only require one monitoring station but also suffer from severe air pollution.

View Article and Find Full Text PDF

The Taguchi method of designing experiments is based on a system of tabulated designs (arrays) that enables the maximum number of variables to be estimated in a neutral (orthogonal) balanced manner with a minimum number of experimental sets. Heavy metals remediation of aqueous streams is of special concern due to its highly toxic and persistent nature. Taguchi approach was used for enhanced bioadsorptive removal of Pb(II), Cu(II) and Cd(II) from aqueous solutions using agroindustrial waste biomass from globe artichoke as inexpensive sorbent.

View Article and Find Full Text PDF

In this paper, the influence of sample pressure on benzene measurements obtained with two automated in situ gas chromatographs is studied. The analysers were calibrated using a non-linear regression at 293 ± 1 K and 101.3 ± 0.

View Article and Find Full Text PDF

We report the preparation and validation of the first fully synthetic gaseous reference standards of CO2 and CH4 in a whole air matrix with an isotopic distribution matching that is in the ambient atmosphere. The mixtures are accurately representative of the ambient atmosphere and were prepared gravimetrically. The isotopic distribution of the CO2 was matched to the abundance in the ambient atmosphere by blending (12)C-enriched CO2 with (13)C-enriched CO2 in order to avoid measurement biases introduced by measurement instrumentation detecting only certain isotopologues.

View Article and Find Full Text PDF

An assessment of uncertainty in the hourly and annual limit values of NO 2 measurements by molybdenum NO2-to-NO conversion followed by chemiluminescence detection was carried out at 3 different span concentrations (100, 300 and 700 nmol mol (-1)). The uncertainty of the linearity term was calculated for each span concentration by considering (i) a zero-and-span calibration and (ii) a multipoint calibration. Two uncertainty models were applied for the overall uncertainty estimation: (i) the Standard EN 14211 and (ii) a mechanistic model that considers the NO 2 reduction in the converter.

View Article and Find Full Text PDF

Observation-based methods are useful tools to explore the sensitivity of ozone concentrations to precursor controls. With the aim of assessing the ozone precursor sensitivity in two locations: Paterna (suburban) and Villar del Arzobispo (rural) of the Turia river basin in the east of Spain, the photochemical indicator O(3)/NO(y) and the Extent-of-Reaction (EOR) parameter have been calculated from field measurements. In Paterna, the O(3)/NO(y) ratio varied from 0 to 13 with an average value of 5.

View Article and Find Full Text PDF

Diffusive samplers were used to measure the vertical concentrations of benzene, toluene, n-hexane, cyclohexane, ethylbenzene and o-, m- and p-xylenes on both sides of two NS-oriented street canyons in Murcia (Spain) during a 5-day period. Non-dimensional relationships of concentration and height were calculated in order to study the behaviour of their concentration vertical profiles. The results show that the vertical profiles of benzene, toluene, n-hexane and cyclohexane concentrations were similar in both streets and on both sides of each street.

View Article and Find Full Text PDF

According to Directive 2008/50/EC, all equipment used for NO(x) fixed measurements must comply with the reference method or equivalent by 11 June 2013. Up to that date, non-type-approved equipment can continue to be used in air monitoring networks and will probably also be used in air pollution studies even after that date. In this context, it is advisable to know how these "old" measuring instruments respond to the requirements of European Standard EN 14211: 2005: Ambient Air Quality--Standard method for the measurement of the concentration of nitrogen dioxide and nitrogen monoxide by chemiluminescence.

View Article and Find Full Text PDF

Users of automatic air pollution monitors are largely unaware of how certain parameters, like temperature, can affect readings. The present work examines the influence of temperature changes on chemiluminescence NO(x) measurements made with a Thermo Scientific 42i analyzer, a model widely used in air monitoring networks and air pollution studies. These changes are grouped into two categories according to European Standard EN 14211: (1) changes in the air surrounding the analyzers and (2) changes in the sampled air.

View Article and Find Full Text PDF

Introduction: The change in light intensity that takes place when an ambient air sample is drawn into the detection chamber of a chemiluminescence monitor generates changes in the concentrations of several species, such as NO(2), NO and O(3). Although this phenomenon has been known for several decades, there is still no commonly accepted approach on when or how to correct for it in NO(2) and O(3) readings.

Discussion: In this work, we have assessed the expanded uncertainty of two chemiluminescence NO( x ) analysers commercially available according to EN 14211:2005, with the aim of establishing the maximum allowable standard uncertainty due to the reaction between NO and O(3) in the sampling system.

View Article and Find Full Text PDF

This paper describes a novel methodology for evaluating the extent to which petrol stations affect their surroundings. The method is based on the fact that the ratio of the concentrations of aliphatic and aromatic hydrocarbon pollutants in the air of the petrol stations and their surroundings (basically determined by vapor emissions from unburned gasoline) differs from the ratio found in urban air, which is mainly influenced by traffic emissions. Bearing this in mind, the spatial limit of influence of petrol stations in any direction would be the first point, moving away from the station, where the ratio becomes equal to the urban background ratio.

View Article and Find Full Text PDF

The objective of this paper is to propose a methodology to estimate the consequences to buildings from the pressure wave caused by unconfined vapour cloud explosions (VCEs). This methodology is based on the use of characteristic overpressure-impulse-distance curves, shown in a previous paper [F. Diaz Alonso, E.

View Article and Find Full Text PDF