Publications by authors named "Marquie C"

Background And Aims: Prophylactic implantable cardioverter-defibrillators (ICDs) are not recommended until left ventricular ejection fraction (LVEF) has been reassessed 40 to 90 days after an acute myocardial infarction. In the current therapeutic era, the prognosis of sustained ventricular arrhythmias (VAs) occurring during this early post-infarction phase (i.e.

View Article and Find Full Text PDF

Background: Hypertrophic cardiomyopathy (HCM) is rare in children, and sudden cardiac death (SCD) is difficult to predict. Two prognostic scores - HCM Risk-Kids and Precision Medicine for Cardiomyopathy (PRIMaCY) - were developed to assess the risk of SCD in the next 5 years in children with HCM.

Aims: To test the ability of these scores to predict SCD in children with HCM.

View Article and Find Full Text PDF

Background: Electrocardiographic screening before subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation is unsuccessful in around 10% of cases. A personalized screening method, by slightly moving the electrodes, to obtain a better R/T ratio has been described to overcome traditional screening failure.

Objective: The objectives of the SIS study were to assess to what extent a personalized screening method improves eligibility for S-ICD implantation and to evaluate the inappropriate shock rate after such screening success.

View Article and Find Full Text PDF

Background: The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown.

Methods: We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system.

View Article and Find Full Text PDF

Background: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events.

Objective: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias.

View Article and Find Full Text PDF
Article Synopsis
  • Very few studies have explored the effectiveness of subcutaneous implantable cardioverter-defibrillators (S-ICDs) in patients with congenital heart disease (CHD), which this research aims to address.
  • In a French cohort study of 4,924 patients implanted with an S-ICD, only 101 were found to have CHD, often presenting at a younger age and more often for secondary prevention compared to non-CHD patients.
  • The study found that while patients with CHD had a higher crude risk of receiving appropriate shocks from their S-ICD, this risk was not significant after adjusting for other factors, indicating that complications and inappropriate shocks were similar across both patient groups.
View Article and Find Full Text PDF
Article Synopsis
  • - This study focuses on patients with repaired tetralogy of Fallot, particularly examining characteristics of those experiencing rapid ventricular tachycardia (VT) and the potential progression from nonrapid VT to rapid VT or ventricular fibrillation (VF).
  • - Researchers analyzed data from a nationwide registry and found that out of 144 patients, 61 experienced VT or VF episodes, with 28 classified as rapid, revealing distinct clinical differences between the rapid and nonrapid groups, such as age at implantation and cardiac history.
  • - The study concludes that patients with rapid VT/VF show specific clinical traits, and the consistent VT cycle lengths over time may indicate a chance for catheter ablation without needing an implantable cardioverter-defibrillator (
View Article and Find Full Text PDF

Background: Women with congenital heart disease at high risk for sudden cardiac death have been poorly studied thus far.

Objectives: The aim of this study was to assess sex-related differences in patients with tetralogy of Fallot (TOF) and implantable cardioverter-defibrillators (ICDs).

Methods: Data were analyzed from the DAI-T4F (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator) cohort study, which has prospectively enrolled all patients with TOF with ICDs in France since 2010.

View Article and Find Full Text PDF
Article Synopsis
  • The study focused on understanding the factors that lead to inappropriate shocks from subcutaneous implantable cardioverter defibrillators (S-ICDs) in patients.
  • The research involved 300 patients over an average follow-up of about 23 months, finding that 8.7% experienced inappropriate shocks primarily due to supraventricular arrhythmias and sensing issues.
  • Key factors identified that predicted the risk of inappropriate shocks included fewer sensing vectors during pre-implant screening, specific ECG characteristics, a history of certain heart conditions, and being overweight.
View Article and Find Full Text PDF
Article Synopsis
  • The study evaluated the effect of pulmonary valve replacement (PVR) on the incidence of ventricular arrhythmias in tetralogy of Fallot (TOF) patients who have implantable cardioverter-defibrillators (ICDs).
  • Results showed that among the 165 TOF patients monitored, those who underwent PVR experienced significantly fewer appropriate ICD therapies after the surgery compared to before, indicating a reduction in arrhythmia burden.
  • The findings suggest that PVR may play a crucial role in decreasing the risk of arrhythmias and highlight the importance of considering PVR in the treatment plans for high-risk TOF patients.
View Article and Find Full Text PDF

Background: Reversion of an implantable cardioverter defibrillator (ICD) to back-up mode degrades the operating capabilities of the device, puts patients at risk and requires rapid intervention by a manufacturer's technician.

Aim: To illustrate the usefulness of remote monitoring of ICDs for the early detection of reversion to back-up mode.

Methods: In our centre, all patients implanted with an ICD, with or without resynchronisation, were offered remote monitoring as soon as the technology became available.

View Article and Find Full Text PDF

Background: Frequency and distribution of left ventricular (LV) venous collaterals were studied in vivo to evaluate the ease and feasibility of implanting a new ultra-thin LV quadripolar microlead for cardiac resynchronization therapy (CRT).

Methods and results: Evaluable venograms were analyzed to define the prevalence of venous collaterals (>0.5 mm diameter) between: (1) different LV segments; and (2) different major LV veins in: unselected patients who underwent CRT from 2008 to 2012 at Rouen Hospital, France (retrospective); and CRT patients from the Axone Acute pilot study in 2018 (prospective).

View Article and Find Full Text PDF

Aims: FRench Attitude reGistry in case of ICD LEad replacement (FRAGILE) registry was set-up to describe the attitude in different French institutions in case of implantable cardioverter-defibrillator (ICD) lead replacement, extraction, or abandonment and to compare outcomes in both groups.

Methods And Results: Prospective observational study comparing two attitudes in case of ICD lead replacement, extraction, or abandonment. Primary endpoint describes the attitude in different French centres, collect parameters that may influence the decision.

View Article and Find Full Text PDF

Background: Tetralogy of Fallot (TOF) is the most common cyanotic congenital heart disease, and sudden cardiac death represents an important mode of death in these patients. Data evaluating the implantable cardioverter defibrillator (ICD) in this patient population remain scarce.

Methods: A Nationwide French Registry including all patients with tetralogy of Fallot with an ICD was initiated in 2010 by the French Institute of Health and Medical Research.

View Article and Find Full Text PDF

Objectives: The aim of this multicenter study was to characterize the efficacy and safety of subcutaneous implantable cardioverter-defibrillators (S-ICDs) lead extraction procedures.

Background: S-ICDs have been developed to limit lead-related complications inherent to transvenous ICD devices. To date, no study has specifically investigated the safety and feasibility of S-ICD lead extraction procedures.

View Article and Find Full Text PDF

Background: In this study we aimed to assess long-term outcomes in subcutaneous implantable cardioverter-defibrillator (S-ICD) recipients with structural heart disease by focussing especially on shock incidence, predictors, and associated prognoses.

Methods: In this multicenter registry‒based study, we retrospectively included all patients who underwent S-ICD implantation at 3 tertiary centers. The prognostic impact of S-ICD shock was assessed with a composite outcome that included all-cause death and hospitalisation for heart failure.

View Article and Find Full Text PDF

The introduction of a new technology always raises questions about its place compared with the reference technology. The use of an implantable cardioverter defibrillator to prevent sudden cardiac death is now a widely proven technique, with a clear statement of its indication in the guidelines. More recently, a subcutaneous implantable cardioverter defibrillator has been introduced, and appears to be an attractive technique as it removes the need to implant a lead inside the right ventricle to treat the patient, which should dramatically decrease the risk of complications over time.

View Article and Find Full Text PDF

In transvenous implantable cardioverter-defibrillator (TV-ICD) implants, routine defibrillation testing (DFT) does not improve shock efficacy or reduce arrhythmic death but patients are exposed to the risk of complications related to DFT. The conversion rate of DFT in subcutaneous ICD (S-ICD) is high and first shock efficacy is similar to TV-ICD efficacy rates. STUDY DESIGN: The PRAETORIAN-DFT trial is an investigator-initiated, randomized, controlled, multicenter, prospective two-arm trial designed to demonstrate non-inferiority of omitting DFT in patients undergoing S-ICD implantation in which the S-ICD system components are optimally positioned.

View Article and Find Full Text PDF

Background The natural history and long-term outcome in pediatric patients with idiopathic ventricular fibrillation ( IVF ) are poorly characterized. We sought to define the clinical characteristics and long-term outcomes of a pediatric cohort with an initial diagnosis of IVF . Methods and Results Patients were included from an International Registry of IVF (consisting of 496 patients).

View Article and Find Full Text PDF

Introduction: Several clinical studies have demonstrated that remote monitoring (RM) offers potential benefits in transvenous implantable cardioverter defibrillator (ICD). The potential interest of RM in subcutaneous-ICD (S-ICD) recipients has never been evaluated. The aim of this study was to evaluate the alert burden and its clinical relevance in a prospective cohort of S-ICD recipients.

View Article and Find Full Text PDF

Objective: Off-label prescription is a common practice in psychiatry, raising health and economic concerns. Collegial consultation could allow a framed prescription of treatments that are not authorized in specific indications. Attention Deficit Hyperactivity in adult populations (ADHD) is a striking example of a pathology where off-label prescription is frequent.

View Article and Find Full Text PDF