Understanding the neural basis of speech perception requires that we study the human brain both at the scale of the fundamental computational unit of neurons and in their organization across the depth of cortex. Here we used high-density Neuropixels arrays to record from 685 neurons across cortical layers at nine sites in a high-level auditory region that is critical for speech, the superior temporal gyrus, while participants listened to spoken sentences. Single neurons encoded a wide range of speech sound cues, including features of consonants and vowels, relative vocal pitch, onsets, amplitude envelope and sequence statistics.
View Article and Find Full Text PDFNeuropixels are silicon-based electrophysiology-recording probes with high channel count and recording-site density. These probes offer a turnkey platform for measuring neural activity with single-cell resolution and at a scale that is beyond the capabilities of current clinically approved devices. Our team demonstrated the first-in-human use of these probes during resection surgery for epilepsy or tumors and deep brain stimulation electrode placement in patients with Parkinson's disease.
View Article and Find Full Text PDFHigh-density, integrated silicon electrodes have begun to transform systems neuroscience, by enabling large-scale neural population recordings with single cell resolution. Existing technologies, however, have provided limited functionality in nonhuman primate species such as macaques, which offer close models of human cognition and behavior. Here, we report the design, fabrication, and performance of Neuropixels 1.
View Article and Find Full Text PDFThe action potential is a fundamental unit of neural computation. Even though significant advances have been made in recording large numbers of individual neurons in animal models, translation of these methodologies to humans has been limited because of clinical constraints and electrode reliability. Here, we present a reliable method for intraoperative recording of dozens of neurons in humans using the Neuropixels probe, yielding up to ∼100 simultaneously recorded single units.
View Article and Find Full Text PDFRecent advances in multi-electrode array technology have made it possible to monitor large neuronal ensembles at cellular resolution in animal models. In humans, however, current approaches restrict recordings to a few neurons per penetrating electrode or combine the signals of thousands of neurons in local field potential (LFP) recordings. Here we describe a new probe variant and set of techniques that enable simultaneous recording from over 200 well-isolated cortical single units in human participants during intraoperative neurosurgical procedures using silicon Neuropixels probes.
View Article and Find Full Text PDFDuring adult rodent life, newborn neurons are added to the olfactory bulb (OB) in a tightly controlled manner. Upon arrival in the OB, input synapses from the local bulbar network and the higher olfactory cortex precede the formation of functional output synapses, indicating a possible role for these regions in newborn neuron survival. An interplay between the environment and the piriform cortex in the regulation of newborn neuron survival has been suggested.
View Article and Find Full Text PDFMeasuring the dynamics of neural processing across time scales requires following the spiking of thousands of individual neurons over milliseconds and months. To address this need, we introduce the Neuropixels 2.0 probe together with newly designed analysis algorithms.
View Article and Find Full Text PDFBackground: The cortical slow (∼1 Hz) oscillation (SO), which is thought to play an active role in the consolidation of memories, is a brain rhythm characteristic of slow-wave sleep, with alternating periods of neuronal activity and silence. Although the laminar distribution of cortical activity during SO is well-studied by using linear neural probes, traditional devices have a relatively low (20-100 μm) spatial resolution along cortical layers.
New Method: In this work, we demonstrate a high-density linear silicon probe fabricated to record the SO with very high spatial resolution (∼6 μm), simultaneously from multiple cortical layers.
Optogenetic manipulations are widely used for investigating the contribution of genetically identified cell types to behavior. Simultaneous electrophysiological recordings are less common, although they are critical for characterizing the specific impact of optogenetic manipulations on neural circuits in vivo. This is at least in part because combining photostimulation with large-scale electrophysiological recordings remains technically challenging, which also poses a limitation for performing extracellular identification experiments.
View Article and Find Full Text PDFWe present a high electrode density and high channel count CMOS (complementary metal-oxide-semiconductor) active neural probe containing 1344 neuron sized recording pixels (20 µm × 20 µm) and 12 reference pixels (20 µm × 80 µm), densely packed on a 50 µm thick, 100 µm wide, and 8 mm long shank. The active electrodes or pixels consist of dedicated in-situ circuits for signal source amplification, which are directly located under each electrode. The probe supports the simultaneous recording of all 1356 electrodes with sufficient signal to noise ratio for typical neuroscience applications.
View Article and Find Full Text PDFObjective: This study investigates the suitability of a thin sheet of extracellular matrix (ECM) proteins as a resorbable coating for temporarily reinforcing fragile or ultra-low stiffness thin-film neural implants to be placed on the brain, i.e. microelectrocorticographic (µECOG) implants.
View Article and Find Full Text PDFModulation of a group of cells or tissue needs to be very precise in order to exercise effective control over the cell population under investigation. Optogenetic tools have already demonstrated to be of great value in the study of neuronal circuits and in neuromodulation. Ideally, they should permit very accurate resolution, preferably down to the single cell level.
View Article and Find Full Text PDFObjective: This paper describes a low power closed-loop compressive sensing (CS) based neural recording system. This system provides an efficient method to reduce data transmission bandwidth for implantable neural recording devices. By doing so, this technique reduces a majority of system power consumption which is dissipated at data readout interface.
View Article and Find Full Text PDFWe have developed a novel type of neural electrode array for future brain-machine interfaces (BMI) and neural implants requiring high resolution recording and stimulation on the surface of brain lesions or on the cortex. The devices differ on two points from commonly used thin film electrode arrays: first, the thin film backbone of the implant is exceptionally thin (down to 5 microns) and finely patterned into spring-like structures. This increases the flexibility of the electrode array and allows stretching and conforming better to a quasi spherical cavity surface.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
September 2013
The signal-to-noise ratio of in vivo extracellular neural recordings with microelectrodes is influenced by many factors including the impedance of the electrode-tissue interface, the noise of the recording equipment and biological background noise from distant neurons. In this work we study the different noise sources affecting the quality of neural signals. We propose a simplified noise model as an analytical tool to predict the noise of an electrode given its geometrical dimensions and impedance characteristics.
View Article and Find Full Text PDFBackground: In preparation for a multicenter study, a protocol was written on how to perform surgical targeting of the bed nucleus of the stria terminalis, based on the lead implantation experience in patients with treatment-refractory obsessive-compulsive disorder (OCD) at the Universitaire Ziekenhuizen Leuven (UZ Leuven). When analyzing the postoperative images, we were struck by the fact that the difference between the postoperative position of the leads and the planned position seemed larger than expected.
Methods: The precision of targeting in four patients with severe OCD who received bilateral model 3391 leads (Medtronic) was compared with the precision of targeting in the last seven patients who underwent surgery at UZ Leuven for movement disorders (four with Parkinson disease and three with essential tremor; all received bilateral leads).
In search of a new potential target for deep brain stimulation in patients with obsessive-compulsive disorder (OCD), we evaluated the single-cell activity of neurons in the bed nucleus of the stria terminalis (BST) in urethane-anesthetized rats in an animal model for OCD, the schedule-induced polydipsia (SIP) model, and compared this to the BST activity in control rats and to a third group of rats which were introduced in the model but did not develop the SIP, and thus were considered resistant. We compared the firing rate and firing pattern of BST neurons between these groups, between hemispheres and made a correlation of the firing rate and firing pattern to the position in the BST. The variability of BST neurons in SIP rats was lower and the randomness higher than BST neurons in control rats or resistant rats.
View Article and Find Full Text PDFUnderstanding the mechanical interactions between implants and the surrounding tissue is known to have an important role for improving the bio-compatibility of such devices. Using a recently developed model, a particular micro-machined neural implant design aiming the reduction of insertion forces dependence on the insertion speed was optimized. Implantations with 10 and 100 μm/s insertion speeds showed excellent agreement with the predicted behavior.
View Article and Find Full Text PDFThe glucose metabolism in the mediodorsal thalamus (MD) is increased in rats in the activity-based anorexia (ABA) model. In patients, electrical stimulation in hyperactive brain regions reduced symptoms in e.g.
View Article and Find Full Text PDFObject: One quarter of patients with anorexia nervosa have a poor outcome and continue to suffer chronically or die. Electrical brain stimulation may be of therapeutic benefit in some of these patients; however, the brain target for inducing symptom relief is unknown. In this study, the authors evaluated the effects of acute and chronic electrical stimulation in the lateral hypothalamus on food intake, locomotor activity, and survival time in rats in an activity-based anorexia model.
View Article and Find Full Text PDFObjectives. Electrical brain stimulation is used as a treatment for patients with intractable chronic pain and movement disorders. However, the implantation of electrodes and electrical stimulation may induce histological changes around the electrode tip.
View Article and Find Full Text PDF