Quantitative bottom-up shotgun lipidomics relies on molecular species-specific "signature" fragments consistently detectable in tandem mass spectra of analytes and standards. Molecular species of glycerophospholipids are typically quantified using carboxylate fragments of their fatty acid moieties produced by higher-energy collisional dissociation of their molecular anions. However, employing standards whose fatty acids moieties are similar, yet not identical, to the target lipids could severely compromise their quantification.
View Article and Find Full Text PDFShotgun proteomics is a powerful technology for global analysis of proteins and their post-translational modifications. Here, we investigate the faster sequencing speed of the latest Q Exactive HF mass spectrometer, which features an ultra-high-field Orbitrap mass analyzer. Proteome coverage is evaluated by four different acquisition methods and benchmarked across three generations of Q Exactive instruments (ProteomeXchange data set PXD001305).
View Article and Find Full Text PDFIn mass spectrometry-based proteomics, data-independent acquisition (DIA) strategies can acquire a single data set useful for both identification and quantification of detectable peptides in a complex mixture. However, DIA data are noisy owing to a typical five- to tenfold reduction in precursor selectivity compared to data obtained with data-dependent acquisition or selected reaction monitoring. We demonstrate a multiplexing strategy, MSX, for DIA analysis that increases precursor selectivity fivefold.
View Article and Find Full Text PDFMol Cell Proteomics
December 2012
There is an immediate need for improved methods to systematically and precisely quantify large sets of peptides in complex biological samples. To date protein quantification in biological samples has been routinely performed on triple quadrupole instruments operated in selected reaction monitoring mode (SRM), and two major challenges remain. Firstly, the number of peptides to be included in one survey experiment needs to be increased to routinely reach several hundreds, and secondly, the degree of selectivity should be improved so as to reliably discriminate the targeted analytes from background interferences.
View Article and Find Full Text PDFIn the present study, a new type of mass spectrometer combining a quadrupole mass filter, a higher collision dissociation (HCD) cell and an Orbitrap detector, was evaluated for the analysis of dried blood spots (DBS) in doping controls. DBS analysis is characterized by the necessity to detect prohibited compounds in sub-nanogram-per-milliliter levels with high identification capacity. After extraction of DBS with an organic solvent and liquid chromatographic separation (using a regular C18-RP-analytical UHPLC-column) of target analytes, mass spectrometry is performed with a high-resolution full scan in positive and negative mode by means of electrospray ionisation.
View Article and Find Full Text PDFBackground: Today, dementias are diagnosed late in the course of disease. Future treatments have to start earlier in the disease process to avoid disability requiring new diagnostic tools. The objective of this study is to develop a new method for the differential diagnosis and identification of new biomarkers of Alzheimer's disease (AD) using capillary-electrophoresis coupled to mass-spectrometry (CE-MS) and to assess the potential of early diagnosis of AD.
View Article and Find Full Text PDFBecause of its availability, ease of collection, and correlation with physiology and pathology, urine is an attractive source for clinical proteomics/peptidomics. However, the lack of comparable data sets from large cohorts has greatly hindered the development of clinical proteomics. Here, we report the establishment of a reproducible, high resolution method for peptidome analysis of naturally occurring human urinary peptides and proteins, ranging from 800 to 17,000 Da, using samples from 3,600 individuals analyzed by capillary electrophoresis coupled to MS.
View Article and Find Full Text PDFJ Am Soc Mass Spectrom
August 2009
Current approaches to discovery-stage drug metabolism studies (pharmacokinetics, microsomal stability, etc.) typically use triple-quadrupole-based approaches for quantitative analysis. This necessitates the optimization of parameters such as Q1 and Q3 m/z values, collision energy, and interface voltages.
View Article and Find Full Text PDFOwing to its availability, ease of collection, and correlation with pathophysiology of diseases, urine is an attractive source for clinical proteomics. However, many proteomic studies have had only limited clinical impact, due to factors such as modest numbers of subjects, absence of disease controls, small numbers of defined biomarkers, and diversity of analytical platforms. Therefore, it is difficult to merge biomarkers from different studies into a broadly applicable human urinary proteome database.
View Article and Find Full Text PDFWe evaluated the utility of SDS-PAGE/Western blot and CE coupled with MS (CE-MS) for detection of urinary polypeptide biomarkers of renal disease in patients with IgA-associated glomerulonephritides. In a reference cohort of 402 patients with various renal disorders and 207 healthy controls, we defined CE-MS patterns of renal damage and IgA nephropathy (IgAN). In a blinded analysis of a separate cohort of patients with IgAN (n = 10), Henoch-Schoenlein purpura (HSP) with nephritis (n = 10), and IgA-associated glomerulonephritis due to hepatitis C virus (HCV)-induced cirrhosis (n = 9), and healthy controls (n = 12), we compared SDS-PAGE/Western blot and CE-MS against clinical urinalysis for detection of urinary proteins/polypeptides.
View Article and Find Full Text PDFUrinary proteomics is emerging as a powerful non-invasive tool for diagnosis and monitoring of variety of human diseases. We tested whether signatures of urinary polypeptides can contribute to the existing biomarkers for coronary artery disease (CAD). We examined a total of 359 urine samples from 88 patients with severe CAD and 282 controls.
View Article and Find Full Text PDFAcute graft-versus-host disease (aGvHD) contributes significantly to morbidity and mortality after allogeneic hematopoietic stem cell transplantation (allo-HSCT). Diagnosis of GvHD is mainly based on clinical features and tissue biopsies. A noninvasive, unbiased laboratory test for GvHD diagnosis does not exist.
View Article and Find Full Text PDFThe objective of this work was the application of peptidomics technologies for the detection and identification of reliable and robust biomarkers for Alzheimer's disease (AD) contributing to facilitate and further improve the diagnosis of AD. Using a new method for the comprehensive and comparative profiling of peptides, the differential peptide display (DPD), 312 cerebrospinal fluid (CSF) samples from AD patients, cognitively unimpaired subjects and from patients suffering from other primary dementia disorders were analysed as four independent analytical sets. By combination with a cross validation procedure, candidates were selected from a total of more than 6,000 different peptide signals based on their discriminating power.
View Article and Find Full Text PDFComb Chem High Throughput Screen
December 2005
Type 2 diabetes mellitus (T2DM) is caused by the failure of the pancreatic beta-cell to secrete sufficient insulin to compensate a decreased response of peripheral tissues to insulin action. The pathological events causing beta-cell dysfunctions are only poorly understood and early markers that would predict islet function are missing. In contrast to immunoassays, unbiased proteomic technologies provide the opportunity to screen for novel marker protein and peptides of T2DM.
View Article and Find Full Text PDFComb Chem High Throughput Screen
December 2005
Detection and purification of novel bioactive peptides from biological sources is a scientific task that led to a substantial number of important discoveries. One major laborious approach used is the repetitive stepwise separation of the test sample into several fractions followed by the determination of their bioactivity, until purity allows for sequence identification. We tested whether functional peptidomics, a combination of biological read-outs with differential peptide display (DPD) is a suitable strategy to isolate bioactive peptides at lower workload and with improved success.
View Article and Find Full Text PDFComb Chem High Throughput Screen
December 2005
Native peptides and proteins are of increasing interest in biomedical research because they hold promise to represent a large number of useful diagnostic and therapeutic biomarkers. Discovery attempts from patient samples have to deal with the complexity of biology from a disease perspective as well as with a high individual variability. High throughput screening of samples is therefore the strategy of choice to detect relevant peptidic biomarkers, and requires a high order of automation particularly in the detection process.
View Article and Find Full Text PDFComb Chem High Throughput Screen
December 2005
Mass spectrometric plasma analysis for biomarker discovery has become an exploratory focus in proteomic research: the challenges of analyzing plasma samples by mass spectrometry have become apparent not only since the human proteome organization (HUPO) has put much emphasis on the human plasma proteome. This work demonstrates fundamental proteomic research to reveal sensitivity and quantification capabilities of our Peptidomics technologies by detecting distinct changes in plasma peptide composition in samples after challenging healthy volunteers with orally administered glucose. Differential Peptide Display (DPD) is a technique for peptidomics studies to compare peptides from distinct biological samples.
View Article and Find Full Text PDFProteomics studies aiming at a detailed analysis of proteins, and peptidomics, aiming at the analysis of the low molecular weight proteome (peptidome) offer a promising approach to discover novel biomarkers valuable for different crucial steps in detection, prevention and treatment of disease. Much emphasis has been given to the analysis of blood, since this source would by far offer the largest number of meaningful biomarker applications. Blood is a complex liquid tissue that comprises cells and extra-cellular fluid.
View Article and Find Full Text PDFThe data collected by Human Proteome Organization's Plasma Proteome Pilot project phase was analyzed by members of our working group. Accordingly, a functional annotation of the human plasma proteome was carried out. Here, we report the findings of our analyses.
View Article and Find Full Text PDFThe human Plasma Proteome Project pilot phase aims to analyze serum and plasma specimens to elucidate specimen characteristics by various proteomic techniques to ensure sufficient sample quality for the HUPO main phase. We used our proprietary peptidomics technologies to analyze the samples distributed by HUPO. Peptidomics summarizes technologies for visualization, quantitation, and identification of the low-molecular-weight proteome (<15 kDa), the "peptidome.
View Article and Find Full Text PDFProfiling of peptides and small proteins from either human body fluids or tissues by chromatography and subsequent mass spectrometry reveals several thousand individual peptide signals per sample. Any peptide is an intermediate in the course of biosynthesis, post-translational modification (PTM), proteolytic processing and degradation. Changes in the concentration of one peptide often affects the concentration of the other, hence a challenge consists in the development of suitable tools to turn this large amount of data into biologically relevant information.
View Article and Find Full Text PDFRecent work on protein and peptide biomarker patterns revealed the difficulties in identifying their molecular components, which is indispensable for validation of the biological context. Cerebrospinal fluid and brain tissue are used as sources to discover new biomarkers, e.g.
View Article and Find Full Text PDFBackground: The Val34Leu mutation in the activation peptide of factor XIII (FXIIIA) correlates with a lower incidence of myocardial infarction and ischemic stroke but an increased risk for hemorrhagic stroke. We describe mass spectrometric detection of the activation peptide variants in human serum.
Methods: We used differential peptide display (DPD) to compare comprehensive peptide maps from pairs of serum samples from healthy volunteers.
Breast Cancer Res Treat
May 2003
Expression profiling of RNAs or proteins has become a promising means to investigate the heterogeneity of histopathologically defined classes of cancer. Peptides, representing degradation as well as processing products of proteins offer an even closer insight into cell physiology. Peptides are related to the turnover of cellular proteins and are capable to reflect disease-related changes in homoeostasis of the human body.
View Article and Find Full Text PDF