Background: Accelerated idioventricular rhythm (AIVR) is known as reperfusion arrhythmia in the setting of acute myocardial infarction (AMI). In healthy individuals, it is usually considered to be benign. Alternating bundle branch block (ABBB) often progresses to complete atrioventricular block requiring permanent pacemaker implantation.
View Article and Find Full Text PDFBackground: The subcutaneous ICD (S-ICD™) is an important advance in device therapy for the prevention of sudden cardiac death (SCD). Although current guidelines recommend S-ICD™ use, long-term data are still limited, especially in subgroups. Among several cardiac diseases that prone to SCD, coronary artery disease (CAD) carries several peculiarities that may hamper S-ICD™ therapy in this cohort.
View Article and Find Full Text PDFBackground: Implantable loop recorders (ILR) may be used to detect occult atrial fibrillation (AF) in patients with cryptogenic stroke. At present, there has been no description on the incidental findings of stored episodes in these patients. Furthermore, no standard practice has been established with respect to the duration of continued ECG monitoring in these patients.
View Article and Find Full Text PDFBackground: The subcutaneous ICD is a promising treatment option in patients at risk for sudden cardiac death. Approved in 2009, the first S-ICD in Germany was implanted in June 2010. Although large prospective registry studies have shown safety and efficacy of the system, there is a lack of long-term data with regard to battery longevity of the S-ICD.
View Article and Find Full Text PDFBackground: Implantable cardioverter-defibrillator (ICD) systems are established therapy for prevention of sudden cardiac death. Long-term data on ICD systems in children and adolescents is rare. The present study displays a long-term single-center follow-up of children and adolescents with ICD systems.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
September 2018
Background: The subcutaneous implantable cardioverter defibrillator (S-ICD) has been established as a valuable alternative to transvenous ICD for prevention of sudden cardiac death. The system automatically chooses the optimal sensing vector. However, during follow-up and especially after device replacement we observed a change of the suggested sensing vector in automatic setup.
View Article and Find Full Text PDFObjectives: This study sought to examine the use of the subcutaneous implantable cardioverter-defibrillator (S-ICD) in teenagers and young adults.
Background: The S-ICD is an important advance in device therapy for the prevention of sudden cardiac death. Although guidelines recommend S-ICD use, long-term data are still limited, especially in subgroups.
Background: T-wave oversensing (TWOS) is a feared complication after subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation, potentially leading to inappropriate shocks (IS) with tremendous impact on quality of life.
Hypothesis: Postoperative ergometry facilitates primary and secondary prevention of TWOS or other potential causes of IS and optimizes S-ICD programming.
Methods: We analyze the impact of ergometry guided-programming (EMGP) on primary and secondary prevention of TWOS/IS in S-ICD patients, we screened 146 patients implanted in our center (2010-2016) for the incidence of TWOS/IS during postoperative ergometry.
Herzschrittmacherther Elektrophysiol
March 2018
Inappropriate shocks are a feared complication after implantable cardioverter-defibrillator (ICD) implantation and have a tremendous impact on quality of life. Inappropriate shocks in patients with subcutaneous ICD (S-ICD®, Boston Scientific, Marlborough, MA, USA) have various underlying causes. This review summarizes the current literature on this topic and lists possible treatment options.
View Article and Find Full Text PDFBackground: Atrial fibrillation (AF) is an important cause of stroke. Continuous electrocardiography (ECG) monitoring with software-based analysis algorithms has been suggested to enhance the AF detection rate. We investigated the ability of stroke risk analysis (SRA) in the detection of AF in acute stroke patients.
View Article and Find Full Text PDFObjectives: The subcutaneous implantable cardioverter defibrillator (S-ICD) has been established as an alternative to conventional transvenous ICD for the prevention of sudden cardiac death. Initial studies have shown safety and efficacy of the system with a left parasternal (LP) electrode. However, several case studies reported a right parasternal (RP) position.
View Article and Find Full Text PDFBackground: For prevention of sudden cardiac death, the transvenously implantable cardioverter-defibrillator therapy (tv-ICD) is well accepted. The subcutaneous system (S-ICD) is promising in terms of reducing ICD complications. Nevertheless, the impact of the novel generator position on patients' quality of life (QoL) is yet unknown.
View Article and Find Full Text PDFBackgrounds: The totally subcutaneous implantable defibrillator (S-ICD) has been designed as a new alternative to conventional implantable defibrillators. This system is especially attractive for young patients. However, long-term experience is not yet available.
View Article and Find Full Text PDFBackground: The results of the recently published randomized SIMPLE trial question the role of routine intraoperative defibrillation testing. However, testing is still recommended during implantation of the entirely subcutaneous implantable cardioverter-defibrillator (S-ICD) system. To address the question of whether defibrillation testing in S-ICD systems is still necessary, we analyzed the data of a large, standard-of-care prospective single-center S-ICD registry.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
February 2015
Objectives: This study analyzed the mechanism and risk factors of thoracic aortic aneurysm expansion due to late distal stent graft-induced new entry (dSINE).
Background: This late complication of thoracic endovascular aneurysm repair (TEVAR) for aortic dissection is under-recognized but potentially life-threatening.
Methods: In 142 patients who underwent TEVAR with endovascular entry sealing for acute and chronic aortic type B dissection, using commercially available straight (nontapered) stent-grafts, we examined the oversizing rate, the aortic taper ratio, and the need for reintervention.
Z Evid Fortbild Qual Gesundhwes
June 2014
Background: The German diabetes guideline published in 2010 recommends an annual retinopathy screening for all type 2 diabetics. Patients' and physicians' questions about the need for this routine procedure prompted our critical review.
Methods: Based on guidelines from six industrial nations, recent scientific studies, and from the type 2 disease management programme of North Rhine-Westphalia we reviewed alternative retinopathy screening strategies and their implications for over- and underuse.