Landfill gas (LFG) is formed by microorganisms within a landfill; it can be utilized as a renewable fuel in power plants. Impurities such as hydrogen sulfide and siloxanes can cause significant damage to gas engines and turbines. The aim of this study was to determine the filtration efficiencies of biochar products made of birch and willow to remove hydrogen sulfides, siloxanes, and volatile organic compounds from the gas streams compared to activated carbon.
View Article and Find Full Text PDFBiocomposites (BCs) can be used as substitutes for unsustainable polymers in 3D printing, but their safety demands additional investigation as biological fillers may produce altered emissions during thermal processing. Commercial filament extruders can be used to produce custom feedstocks, but they are another source of airborne contaminants and demand further research. These knowledge gaps are targeted in this study.
View Article and Find Full Text PDFPhotopolymer resins are applied at an increasing rate in additive manufacturing (AM) industry as vat photopolymerization (VP) and material jetting (MJ) methods gain more popularity. The aim of this study was to measure volatile organic compound (VOC), carbonyl compound, ultrafine particle (UFP), and particulate matter (PM) air concentrations emitted in 3D printer operations. Individual chemicals were identified when multiple photopolymer resin feedstocks were used in various VP and MJ printers.
View Article and Find Full Text PDF. The purpose of this study was to examine the effectiveness of intervention strategies to control mass concentrations and peak exposures of flour dust in two Finnish bakeries. The effect of the intervention on the proportion of various particle size fractions of the total particulate matter was also investigated.
View Article and Find Full Text PDFThis study assessed the pyrolysis liquids obtained by slow pyrolysis of industrial hemp leaves, hurds, and roots. The liquids recovered between a pyrolysis temperature of 275-350 °C, at two condensation temperatures 130 °C and 70 °C, were analyzed. Aqueous and bio-oil pyrolysis liquids were produced and analyzed by proton nuclear magnetic resonance (NMR), gas chromatography-mass spectrometry (GC-MS), and atmospheric pressure photoionization Fourier transform ion cyclotron resonance mass spectrometry (APPI FT-ICR MS).
View Article and Find Full Text PDFFor many antibacterial polymer fibres, especially for those with natural functional additives, the antibacterial response might not last over time. Moreover, the mechanical performance of polymeric fibres degrades significantly during the intended operation, such as usage in textile and industrial filter applications. The degradation process and overall ageing can lead to emitted volatile organic compounds (VOCs).
View Article and Find Full Text PDFBlack carbon (BC) is a descriptive term that refers to light-absorbing particulate matter (PM) produced by incomplete combustion and is often used as a surrogate for traffic-related air pollution. Exposure to BC has been linked to adverse health effects. Penetration of ambient BC is typically the primary source of indoor BC in the developed world.
View Article and Find Full Text PDFSpreading and distribution of selected volatile organic compounds (VOCs) released as point source emissions in a hospital environment were investigated in two office rooms and two patient rooms. Six tracer compounds were released from six locations and their concentrations were measured in five sampling sites during two consecutive days. The air flow rates, velocity and flow direction, air temperature, pressure differences between adjacent rooms, and relative humidity and concentrations of the tracer compounds were measured.
View Article and Find Full Text PDFThe floor polish removal (FPR) and reapplication (FPA) are important cleaning tasks in public buildings that have hard floor surfaces. Usually, the FPR and FPA are conducted once or twice a year, during the periodic cleaning of these buildings. The FPR can be performed either chemically (CFPR) or by using dry scrubber (DFPR), when the polish is ground from the floor.
View Article and Find Full Text PDFThe aim of this study was to measure the concentrations of gaseous and particulate contaminants originated from additive manufacturing operations and post-processes in an occupational setting when plastics were used as feedstock materials. Secondary aims were to evaluate the concentration levels based on proposed exposure limits and target values and to propose means to reduce exposure to contaminants released in additive manufacturing processes. Volatile organic compounds were sampled with Tenax TA adsorption tubes and analyzed with a thermo desorption gas chromatography-mass spectrometry instrument.
View Article and Find Full Text PDFIn this case study, hospital workers did suffer from symptoms related to the poor indoor air quality. To investigate reasons for symptoms MM40-survey and house inspection methods were performed. The study consisted of 49 operating rooms and 470 employees.
View Article and Find Full Text PDFInt J Occup Med Environ Health
April 2007
Objectives: The aim of this study was to evaluate the suitability and applicability of low-flow passive tubes for sampling of organic solvents in occupational environment.
Materials And Methods: Laboratory and field studies were conducted to continue the evaluation of low-flow diffusive sampling combined with thermal desorption and gas chromatographic/mass spectrometric analysis in occupational hygiene surveys. Passive sampler tubes with Tenax GR adsorbent were employed to assess exposures to organic solvents in 10 small sheet-fed offset printing plants in Finland.