Publications by authors named "Markl M"

Background: Multiparametric cardiovascular magnetic resonance (CMR) has an emerging role in non-invasive surveillance of pediatric heart transplant recipients (PHTR). Higher myocardial T2, higher extracellular volume fraction (ECV), and late gadolinium enhancement (LGE) have been associated with adverse clinical outcomes in adult heart transplant recipients. This study's purpose was to investigate the prognostic value of CMR-derived T1- and T2-mapping, ECV, and LGE for clinical outcomes in PHTR.

View Article and Find Full Text PDF

Background: Pulmonary artery stenosis, neoaortic dilatation, and neoaortic valve insufficiency are among the most frequent complications of the arterial switch operation for repair of dextro-transposition of the great arteries (d-TGA). It remains difficult to predict which patients will require great arterial reintervention.

Objective: We aimed to characterize hemodynamics within the great arteries using 4D flow MRI in patients with d-TGA after the arterial switch operation.

View Article and Find Full Text PDF

Purpose: To evaluate the reproducibility of important biomarkers like wall shear stress (WSS), pulse wave velocity (PWV), and net flow across two 4D flow MRI imaging protocols with different coverages: aorta-targeted 4D flow MRI (AT4D) and whole-heart 4D flow (WH4D) protocols.

Methods: Thirty-eight control subjects (43.2 ± 10.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates how cardiac implantable electronic devices (CIEDs) affect the accuracy and precision of phase-contrast MRI measurements of aortic velocity in both adult and pediatric patients.
  • A total of 29 subjects (21 adults and 8 children) were scanned using various MRI techniques while simulating the presence of CIEDs to analyze image artifacts.
  • Results showed that the proximity of the CIED to the aortic valve worsens measurement accuracy, with biases and variations increasing as the distance decreases, highlighting the need to consider CIED impact during MRI readings.
View Article and Find Full Text PDF

Four-dimensional phase contrast MRI (4D flow) has emerged as a versatile imaging technique for comprehensive visualization and both qualitative and quantitative assessment of cardiovascular blood flow. 4D flow is a three-dimensional, time-resolved acquisition that is gated to the cardiac cycle. 4D flow provides cardiovascular velocity and flow assessment across the volume of acquisition and yields a multitude of advanced hemodynamic parameters that help to assess the impact of cardiovascular disease on flow and vice versa, guiding the clinical and surgical management of patients with congenital and acquired heart disease.

View Article and Find Full Text PDF

Background: Pulmonary hypertension (PH) is a life-threatening. Differentiation pulmonary arterial hypertension (PAH) from pulmonary venous hypertension (PVH) is important due to distinct treatment protocols. Invasive right heart catheterization (RHC) remains the reference standard but noninvasive alternatives are needed.

View Article and Find Full Text PDF

Purpose: An automatic method is presented for estimating 4D flow MRI velocity measurement uncertainty in each voxel. The velocity distance (VD) metric, a statistical distance between the measured velocity and local error distribution, is introduced as a novel measure of 4D flow MRI velocity measurement quality.

Methods: The method uses mass conservation to assess the local velocity error variance and the standardized difference of means (SDM) velocity to estimate the velocity error correlations.

View Article and Find Full Text PDF
Article Synopsis
  • The study introduces IMplicit UNrolled NEtworks (IMUNNE) as a new training strategy for dynamic MRI reconstruction, addressing issues of long training times and high GPU memory usage.
  • IMUNNE frames the MRI reconstruction as an implicit fixed-point equation and uses a gradient approximation method, allowing it to work efficiently with deep learning models.
  • Results show that IMUNNE improves image quality and significantly decreases training and inference times compared to existing methods, making it a promising solution for efficient cine MRI imaging.
View Article and Find Full Text PDF

Background: This study aimed to validate respiratory-resolved five-dimensional (5D) flow cardiovascular magnetic resonance (CMR) against real-time two-dimensional (2D) phase-contrast MRI, assess the impact of number of respiratory states, and measure the impact of respiration on hemodynamics in congenital heart disease (CHD) patients.

Methods: Respiratory-resolved 5D flow MRI-derived net and peak flow measurements were compared to real-time 2D phase-contrast MRI-derived measurements in 10 healthy volunteers. Pulmonary-to-systemic flow ratios (Qp:Qs) were measured in 19 CHD patients and aortopulmonary collateral burden was measured in 5 Fontan patients.

View Article and Find Full Text PDF

Background: Aortic diameter growth in type B aortic dissection (TBAD) is associated with progressive aortic dilation, resulting in increased mortality in patients with both de novo TBAD (dnTBAD) and residual dissection after type A dissection repair (rTAAD). Preemptive thoracic endovascular aortic repair may improve mortality in patients with TBAD, although it is unclear which patients may benefit most from early intervention. In vivo hemodynamic assessment using four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) has been used to characterize TBAD patients with growing aortas.

View Article and Find Full Text PDF

Introduction: The rapid development of artificial intelligence (AI) in healthcare has exposed the unmet need for growing a multidisciplinary workforce that can collaborate effectively in the learning health systems. Maximizing the synergy among multiple teams is critical for Collaborative AI in Healthcare.

Methods: We have developed a series of data, tools, and educational resources for cultivating the next generation of multidisciplinary workforce for Collaborative AI in Healthcare.

View Article and Find Full Text PDF

Introduction: Intracranial 4D flow MRI enables quantitative assessment of hemodynamics in patients with intracranial atherosclerotic disease (ICAD). However, quantitative assessments are still challenging due to the time-consuming vessel segmentation, especially in the presence of stenoses, which can often result in user variability. To improve the reproducibility and robustness as well as to accelerate data analysis, we developed an accurate, fully automated segmentation for stenosed intracranial vessels using deep learning.

View Article and Find Full Text PDF

To test the hypothesis that cine MRI-derived radiomics features of the cardiac blood pool can represent hemodynamic characteristics of pulmonary hypertension-heart failure with preserved ejection fraction (PH-HFpEF). Nineteen PH-HFpEF patients (9 male, 57.8 ± 14.

View Article and Find Full Text PDF
Article Synopsis
  • Left atrial (LA) myopathy may lead to silent brain infarctions (SBI) due to altered blood flow, and 4D-flow MRI is used to assess LA hemodynamics.
  • A study involving 125 participants from the MESA population aimed to explore the links between LA and LAA blood flow parameters and the occurrence of SBI.
  • Results showed that older age and reduced peak velocity in the left atrial appendage were significantly associated with a higher likelihood of having SBI.
View Article and Find Full Text PDF

Purpose To investigate associations between left atrial volume (LAV) and function with impaired three-dimensional hemodynamics from four-dimensional flow MRI. Materials and Methods A subcohort of participants from the Multi-Ethnic Study of Atherosclerosis from Northwestern University underwent prospective 1.5-T cardiac MRI including whole-heart four-dimensional flow and short-axis cine imaging between 2019 and 2020.

View Article and Find Full Text PDF

Background: In patients with bicuspid aortic valve (BAV), 4D flow MRI can quantify regions exposed to abnormal aortic hemodynamics, including high wall shear stress (WSS), a known stimulus for arterial wall dysfunction. However, the long-term multiscan reproducibility of 4D flow MRI-derived hemodynamic parameters is unknown.

Purpose: To investigate the long-term stability of 4D flow MRI-derived peak velocity, WSS, and WSS-derived heatmaps in patients with BAV undergoing multiyear surveillance imaging.

View Article and Find Full Text PDF
Article Synopsis
  • - This document serves as an evidence-based guideline for naming and classifying congenital bicuspid aortic valve and its associated conditions, aimed at a wide range of medical professionals.
  • - It is designed for use by pediatricians, cardiologists, surgeons, and researchers, ensuring clarity across various healthcare fields.
  • - The consensus is subject to updates as new research and key findings emerge, highlighting its dynamic nature in adapting to evolving medical knowledge.
View Article and Find Full Text PDF

Background: Four-dimensional (4D) flow magnetic resonance imaging (MRI) often relies on the injection of gadolinium- or iron-oxide-based contrast agents to improve vessel delineation. In this work, a novel technique is developed to acquire and reconstruct 4D flow data with excellent dynamic visualization of blood vessels but without the need for contrast injection. Synchronization of Neighboring Acquisitions by Physiological Signals (SyNAPS) uses pilot tone (PT) navigation to retrospectively synchronize the reconstruction of two free-running three-dimensional radial acquisitions, to create co-registered anatomy and flow images.

View Article and Find Full Text PDF

4D flow MRI is an emerging imaging modality that maps voxel-wise blood flow information as velocity vector fields that is acquired in 7-dimensional image volumes (3 spatial dimensions + 3 velocity directions + time). Blood flow in the cardiovascular system is often complex and composite involving multiple flow dynamics and patterns (e.g.

View Article and Find Full Text PDF

Purpose: To develop a highly-accelerated, real-time phase contrast (rtPC) MRI pulse sequence with 40 fps frame rate (25 ms effective temporal resolution).

Methods: Highly-accelerated golden-angle radial sparse parallel (GRASP) with over regularization may result in temporal blurring, which in turn causes underestimation of peak velocity. Thus, we amplified GRASP performance by synergistically combining view-sharing (VS) and k-space weighted image contrast (KWIC) filtering.

View Article and Find Full Text PDF

The diagnosis of aneurysms is informed by empirically tracking their size and growth rate. Here, by analysing the growth of aortic aneurysms from first principles via linear stability analysis of flow through an elastic blood vessel, we show that abnormal aortic dilatation is associated with a transition from stable flow to unstable aortic fluttering. This transition to instability can be described by the critical threshold for a dimensionless number that depends on blood pressure, the size of the aorta, and the shear stress and stiffness of the aortic wall.

View Article and Find Full Text PDF

Background: Chronic graft failure (CGF) in pediatric heart transplant (PHT) is multifactorial and may present with findings of fibrosis and microvessel disease (MVD) on endomyocardial biopsy (EMB). There is no optimal CGF surveillance method. We evaluated associations between cardiac magnetic resonance imaging (CMR) and historical/EMB correlates of CGF to assess CMR's utility as a surveillance method.

View Article and Find Full Text PDF

This study aims to assess whether the On-X aortic valved conduit better restores normal valvular and ascending aortic hemodynamics than other commonly used bileaflet mechanical valved conduit prostheses from St. Jude Medical and Carbomedics by using same-day transthoracic echocardiography (TTE) and 4D flow magnetic resonance imaging (MRI) examinations. TTE and 4D flow MRI were performed back-to-back in 10 patients with On-X, six patients with St.

View Article and Find Full Text PDF

Although cine MRI-derived radiomics features in the cardiac blood pool have been used to represent cardiac function and motion, the clinical relevance of radiomics features in the great vessels is still unknown. The aim of the present study was to test the hypothesis that cine MRI-derived radiomics features of the pulmonary artery (PA) can represent hemodynamic abnormalities in pulmonary hypertension (PH). With the approval of the institutional review board (IRB), 50 PH patients (21 males, 36-89 years old, diagnosed with right heart catheterization [RHC]) and 23 healthy volunteers (14 males, 26-80 years old) were retrospectively enrolled in this study.

View Article and Find Full Text PDF

Background: Chronic graft failure and cumulative rejection history in pediatric heart transplant recipients (PHTR) are associated with myocardial fibrosis on endomyocardial biopsy (EMB). Cardiovascular magnetic resonance imaging (CMR) is a validated, non-invasive method to detect myocardial fibrosis via the presence of late gadolinium enhancement (LGE). In adult heart transplant recipients, LGE is associated with increased risk of future adverse clinical events including hospitalization and death.

View Article and Find Full Text PDF