Background: Trials comparing non-vitamin K oral anticoagulant (NOAC) versus antiplatelet-based strategies have shown a reduction of subclinical leaflet thrombosis at the cost of increased mortality and major-bleedings. NOACs were often combined with antiplatelet therapy.
Aims: The Rotterdam Edoxaban (REDOX) study aimed to evaluate the impact of edoxaban monotherapy on the incidence of hypo-attenuated leaflet thickening (HALT) and reduced leaflet motion (RLM) and to evaluate safety in terms of mortality, thromboembolic events and major bleeding.
Background: Transcatheter mitral valve replacement (TMVR) is emerging in the context of annular calcification (valve-in-MAC; ViMAC), failing surgical mitral annuloplasty (mitral-valve-in-ring; MViR) and failing mitral bioprosthesis (mitral-valve-in-valve; MViV). A notorious risk of TMVR is neo left ventricular outflow tract (neo-LVOT) obstruction. Three-dimensional computational models (3DCM) are derived from multi-slice computed tomography (MSCT) and aim to predict neo-LVOT area after TMVR.
View Article and Find Full Text PDFJ Cardiovasc Comput Tomogr
November 2024
Transcatheter aortic valve replacement (TAVR) is preferred therapy for elderly patients with severe aortic stenosis (AS) and increasingly used in younger patient populations with good safety and efficacy outcomes. However, cardiac conduction abnormalities remain a frequent complication after TAVR ranging from relative benign interventriculair conduction delays to prognostically relevant left bundle branch block and complete atrio-ventricular (AV) block requiring permanent pacemaker implantation (PPI). Although clinical, procedural and electrocardiographic factors have been identified as predictors of this complication, there is a need for advanced strategies to control the burden of conduction defects particularly as TAVR shifts towards younger populations.
View Article and Find Full Text PDFModerate aortic stenosis is increasingly recognized as a disease entity with poor prognosis. Diagnosis of moderate aortic stenosis may be complemented by laboratory tests and advanced imaging techniques focused at detecting signs of cardiac damage such as increase of cardiac enzymes (N-terminal pro-B-type Natriuretic Peptide, troponin), left ventricular remodeling (hypertrophy, reduced left ventricular ejection fraction), or myocardial fibrosis. Therapy should include guideline-directed optimal medical therapy for heart failure.
View Article and Find Full Text PDFBackground: Transcatheter mitral valve replacement (TMVR) has emerged as a minimally invasive alternative to mitral valve surgery for patients at high or prohibitive operative risk. Prospective studies reported favourable outcomes in patients with annulus calcification (valve-in-mitral annulus calcification; ViMAC), failed annuloplasty ring (mitral valve-in-ring; MViR), and bioprosthetic mitral valve dysfunction (mitral valve-in-valve; MViV). Multi-slice computed tomography (MSCT)-derived 3D-modelling and simulations may provide complementary anatomical perspectives for TMVR planning.
View Article and Find Full Text PDFThe demonstrated safety and effectiveness of transcatheter aortic valve implantation (TAVI) among low surgical risk patients opened the road to its application in younger low-risk patients. However, the occurrence of conduction abnormalities and need for permanent pacemaker implantation remains a frequent problem associated with adverse outcomes. The clinical implications may become greater when TAVI shifts towards younger populations, highlighting the need for comprehensive strategies to address this issue.
View Article and Find Full Text PDFBackground: Transcatheter aortic valve implantation (TAVI) is considered a safe and effective alternative to surgical aortic valve replacement (SAVR) for elderly patients across the operative risk spectrum. In the Netherlands, TAVI is reimbursed only for patients with a high operative risk. Despite this, one fifth of TAVI patients are < 75 years of age.
View Article and Find Full Text PDFBackground: Data on the likelihood of left ventricle (LV) recovery in patients with severe LV dysfunction and severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) and its prognostic value are limited.
Aims: We aimed to assess the likelihood of LV recovery following TAVI, examine its association with midterm mortality, and identify independent predictors of LV function.
Methods: In our multicentre registry of 17 TAVI centres in Western Europe and Israel, patients were stratified by baseline LV function (ejection fraction [EF] >/≤30%) and LV response: no LV recovery, LV recovery (EF increase ≥10%), and LV normalisation (EF ≥50% post-TAVI).
Structural heart disease interventions rely heavily on preprocedural planning and simulation to improve procedural outcomes and predict and prevent potential procedural complications. Modeling technologies, namely 3-dimensional (3D) printing and computational modeling, are nowadays increasingly used to predict the interaction between cardiac anatomy and implantable devices. Such models play a role in patient education, operator training, procedural simulation, and appropriate device selection.
View Article and Find Full Text PDFLeft ventricular outflow tract obstruction (LVOTO) is a notorious complication of transcatheter mitral valve replacement (TMVR). Computed tomography-derived simulations can predict neo-LVOTO post-TMVR, whereas alcohol septal ablation (ASA) can mitigate neo-LVOTO risk. We report a case of sequential ASA of 2 adjacent septal branches to resolve unexpected neo-LVOTO post-TMVR.
View Article and Find Full Text PDFBackground: Transcatheter edge-to-edge repair (TEER) has become an established treatment for primary and secondary mitral regurgitation (PMR and SMR). The objective of this study was to compare the accuracy of different risk scores for predicting 1-year mortality and the composite endpoint of 1-year mortality and/or heart failure (HF) hospitalization after TEER.
Methods: We analyzed data from 206 patients treated for MR at a tertiary European center between 2011 and 2023 and compared the accuracy of different mitral and surgical risk scores: EuroSCORE II, GRASP, MITRALITY, MitraScore, TAPSE/PASP-MitraScore, and STS for predicting 1-year mortality and the composite of 1-year mortality and/or HF hospitalization in PMR and SMR.
Circ Cardiovasc Interv
November 2023
Background: Redo transcatheter aortic valve implantation (TAVI) is increasing as patients outlive their transcatheter heart valves (THVs) and present with bioprosthetic valve failure. The Lotus mechanically expanded THV has unique design characteristics, which have specific implications for Redo TAVI.
Methods: The design features of the Lotus valve and their relevance to Redo TAVI were reviewed.
Background: Transcatheter valvular interventions affect cardiac and hemodynamic physiology by changing ventricular (un-)loading and metabolic demand as reflected by cardiac mechanoenergetics. Real-time quantifications of these changes are scarce. Pressure-volume loop (PVL) monitoring appraises both load-dependent and load-independent compounds of cardiac physiology including myocardial work, ventricular unloading, and ventricular-vascular interactions.
View Article and Find Full Text PDFLeft ventricular (LV) diastolic dysfunction is one of the important mechanisms responsible for symptoms in patients with heart failure. The aim of the current study was to identify parameters that may be used to detect early signs of LV diastolic dysfunction in diabetic pigs on a high fat diet, using conventional and speckle tracking echocardiography. The study population consisted of 16 healthy Göttingen minipigs and 18 minipigs with experimentally induced metabolic dysfunction.
View Article and Find Full Text PDFBackground: Marfan syndrome (MFS) and familial non-syndromal thoracic aortic aneurysm and dissection (ns-TAAD) are genetic aortopathies causing aortic dilatation with increased aortic stiffness. Left ventricular (LV) contractility and ventricular-vascular coupling index (VVI) were compared between MFS and ns-TAAD and determinants of VVI were investigated.
Methods And Results: Patients with MFS (M 57, F 47) and ns-TAAD (M 72, F 39) were studied by echocardiography and compared with controls (M 77, F 71).