J Aerosol Med Pulm Drug Deliv
October 2024
Preliminary data in a randomly selected pediatric cohort study in 8-year-olds suggested a rate of positivity to a methacholine challenge test that was unexpectedly high, roughly 30%. The current recommendation for a negative methacholine test is a 20% decrease in the forced expiratory volume in one second at a dose greater than 400 μg. This was derived from studies in adults using the obsolete English Wright nebulizer.
View Article and Find Full Text PDFIntroduction: Reusable nebulizer-compressor combinations deliver inhaled medications for patients with chronic lung diseases. On hospital discharge, the patient may take home the disposable nebulizer that was packaged and combine it with their home compressor. Though this practice may reduce waste, it can increase variability in medication delivery.
View Article and Find Full Text PDFMany orally inhaled products are supplied with a facemask instead of a mouthpiece, enabling aerosolized medication to be transferred from the inhaler to the lungs when the user lacks the capability to use a mouthpiece. Until recently, laboratory evaluation of an orally inhaled product-facemask was frequently undertaken by removing the facemask, treating the facemask adapter as being equivalent to a mouthpiece. Measurements of delivered drug mass were therefore subject to bias arising from the absence of dead volume, had the facemask been present.
View Article and Find Full Text PDFExisting pharmacopeial methods for the in vitro testing of orally inhaled products (OIPs) are simplified representations of clinical reality, as their objective is to provide metrics that are discriminating of product quality. Attempts to correlate measures such as fine particle fraction <5 µm aerodynamic diameter with in vivo measures of lung deposition have therefore been notoriously difficult to achieve. Although particle imaging-based techniques may be helpful to link in vitro to in vivo data as surrogates for clinical responses, a reappraisal of the purposes for laboratory-based testing of OIPs is required.
View Article and Find Full Text PDFThe purpose of this study was to resolve an anomalously high measure of extra-fine particle fraction (EPF) determined by the abbreviated cascade impactor possibly relevant for human respiratory tract (AIM-HRT) in the experiment described in Part 1 of this two-part series, in which the relative precision of abbreviated impactors was evaluated in comparison with a full resolution Andersen eight-stage cascade impactor (ACI). Evidence that the surface coating used to mitigate particle bounce was laterally displaced by the flow emerging from the jets of the lower stage was apparent upon microscopic examination of the associated collection plate of the AIM-HRT impactor whose cut point size defines EPF. A filter soaked in surfactant was floated on top of this collection plate, and further measurements were made using the same pressurized metered-dose inhaler-based formulation and following the same procedure as in Part 1.
View Article and Find Full Text PDFThe purpose of this study was to compare relative precision of two different abbreviated impactor measurement (AIM) systems and a traditional multi-stage cascade impactor (CI). The experimental design was chosen to provide separate estimates of variability for each impactor type. Full-resolution CIs are useful for characterizing the aerosol aerodynamic particle size distribution of orally inhaled products during development but are too cumbersome, time-consuming, and resource-intensive for other applications, such as routine quality control (QC).
View Article and Find Full Text PDFBackground: Delivery of bronchodilator to infants and small children from a pressurized metered-dose inhaler with valved holding chamber (pMDI-VHC) is limited by airway narrowness, short respiratory cycle time, and small tidal volume (V(T)). There is a need for a versatile, efficient VHC, given the variety of treatment modalities.
Methods: We tested the AeroChamber Mini VHC (the internal geometry of which is optimized for aerosol delivery, and which accepts a pMDI canister that has a dose counter) in experiments to determine differences in the delivery of hydrofluoroalkane-propelled albuterol (90 microg/actuation) during: mechanical ventilation via endotracheal tube (ETT); manual resuscitation via ETT; and spontaneous breathing via face mask.
Expert Rev Med Devices
March 2009
Although oral inhalers have been mass produced for more than 50 years, there is a large body of literature in which evidence has been provided that patients either misuse their inhalers inadvertently or deliberately, thereby reducing their intended efficacy or, in the worst cases, rendering them altogether ineffective. In general, inhalers are becoming increasingly complicated with the incorporation of add-on devices, miniaturized electronics and ever more complex mechanical systems that aid aerosol delivery to the lower respiratory tract and, at the same time provide user feedback. However, these benefits often come at a significant cost, and there are signs that increasing attention will need to be given to the cost-benefit equation in the future.
View Article and Find Full Text PDFBackground: Valved holding chambers (VHCs) are prescribed with pressurised metered dose inhalers (pMDIs) to improve medication delivery for the treatment of respiratory diseases because they reduce the need for the patient to co-ordinate inhaler actuation with the onset of inhalation. Although mechanically robust and clinically effective if properly designed and pre-conditioned, there are several causes of inconsistent medication delivery if this is not the case. These include: electrostatic charge; incorrect operation of inhalation and exhalation valves; and the fit of the facemask - where present - to the face.
View Article and Find Full Text PDFThe movement of inhaler-generated aerosols is significantly influenced by electrostatic charge on the particles and on adjacent surfaces. Particle charging arises in the aerosol formation process. Since almost all inhalers contain nonconducting components, these surfaces can also acquire charge during manufacture and use.
View Article and Find Full Text PDFThe rapid assessment of aerosols produced by medicinal inhalers is highly desirable from several standpoints, including the assurance of product quality, the development of new delivery systems, and the need to meet an increasing requirement by regulatory bodies for reliable in vitro performance data. Particle size analysis has traditionally been undertaken by cascade impactor on account of the direct assessment of active pharmaceutical ingredient(s) (APIs) that is possible by this method. However, laser diffractometry is less labor-intensive, more rapid, and can be a less invasive procedure.
View Article and Find Full Text PDFThe purpose of this study was to compare three valved holding chambers (VHC) with facemasks attached. One VHC (AeroChamber Max[TM] with medium mask) was made with materials that dissipate surface electrostatic charge, and the others (OptiChamber Advantage and ProChamber[TM] with pediatric facemask) were made from non-conducting materials. The OptiChamber Advantage and ProChamber VHCs were each washed with an ionic detergent and drip dried before testing to minimize surface electrostatic charge.
View Article and Find Full Text PDFBackground: Hydrofluoroalkane-propelled levalbuterol (Xopenex) aerosol is a recently approved formulation for delivery via metered-dose inhaler for the treatment or prevention of bronchospasm in adults, adolescents, and children > or = 4 years of age who have reversible obstructive airway disease. Valved holding chambers (VHCs) made from conventional polymers are susceptible to accumulation of electrostatic charge, which can be minimized by prewashing with ionic detergent, but it may be desirable to be able to use the product straight from the package, without pretreatment, especially during an exacerbation.
Methods: We studied the performance of the AeroChamber Plus and AeroChamber Max VHCs in delivering hydrofluoroalkane-propelled levalbuterol.
Introduction: Electrostatic attraction of aerosolized particles to the inner walls of an aerosol holding chamber (HC) made from a nonconducting material can reduce medication delivery, particularly if there is a delay between actuation and inhalation.
Objective: Compare total emitted mass and fine-particle mass (mass of particles < 4.7 microm) of hydrofluoroalkane-propelled albuterol from similar-sized HCs manufactured from conductive material (Vortex), charge-dissipative material (AeroChamber Max), and nonconductive material (OptiChamber Advantage, ProChamber, Breathrite, PocketChamber, and ACE), with and without wash/rinse pretreatment of the HC interior with ionic detergent, and with 2-s and 5-s delays between actuation and inhalation.
The purpose of this research was to compare three different methods for the aerodynamic assessment of (1) chloroflurocarbon (CFC)--fluticasone propionate (Flovent), (2) CFC-sodium cromoglycate (Intal), and (3) hydrofluoroalkane (HFA)--beclomethasone dipropionate (Qvar) delivered by pressurized metered dose inhaler. Particle size distributions were compared determining mass median aerodynamic diameter (MMAD), geometric standard deviation (GSD), and fine particle fraction <4.7 microm aerodynamic diameter (FPF(<4.
View Article and Find Full Text PDFCascade impactors, including the multi-stage liquid impinger, are by far the most widely encountered means for the in vitro determination of the particle size distribution of aerosols from medical inhalers, both in product development, batch release and in applications with add-on devices. This is because they directly measure aerodynamic size, which is the most relevant parameter to describe particle transport within the respiratory tract. At the same time, it is possible to quantify the mass of active pharmaceutical ingredient in different size ranges independent of other non-physiologically active components of the formulation.
View Article and Find Full Text PDFUnlabelled: We describe a laboratory investigation comparing the delivery of chlorofluorocarbon (CFC)- and hydrofluoroalkane (HFA)-formulated beclomethasone dipropionate (BDP) by metered-dose inhaler and holding chamber (AeroChamber HC MV) in a simulation of a mechanically ventilated adult patient.
Methods: We equipped each HC MV (n = 5) with an 8.0 mm diameter endotracheal tube (ETT), locating the HC MV in the inspiratory limb of a breathing circuit linked to a mechanical ventilator set to simulate tidal breathing at tidal volume = 830 mL, respiratory rate = 15 breaths/min, inspiratory-expiratory ratio of 1:2.
The treatment of both the bronchoconstriction and inflammatory aspects of asthma simultaneously by a single pressurized metered dose inhaler (pMDI) represents a significant advance in convenience to the patient. However, a valved holding chamber (VHC) may still be needed to reduce the coarse component of the dose that is likely to deposit in the oropharyngeal region, and a small sized device may offer significant advantages to the patient from the standpoint of compliance with therapy. VHCs representing small (adult AeroChamber Plus with mouthpiece, 149-mL) and large (Volumatic, 750-mL) devices have been compared in an in vitro evaluation with Seretide/Advair (hydro-fluoro alkane [HFA]-formulated fluticasone propionate [FP = 125 microg/dose] and salmeterol xinafoate [SX = 25 microg/dose]) by Andersen Mark-II eight-stage impactor operated at 28.
View Article and Find Full Text PDFBackground: Current American Thoracic Society and American Association for Respiratory Care guidelines for the delivery of aerosol agents such as methacholine chloride (MC) for bronchoprovocation testing require the use of pneumatic jet nebulizers that have well-defined droplet size and mass output. A recently developed disposable, breath-actuated nebulizer (AeroEclipse) may offer bronchoprovocation testers an alternative to existing devices.
Methods: We studied the performance of 5 AeroEclipse nebulizers with regard to mass of MC delivered with various MC solution concentrations and numbers of inhalations, using a model of adult tidal breathing.
In a previous study, an Aerosizer-LD time-of-flight (TOF) aerosol spectrometer was shown to underestimate significantly the aerodynamic size of airborne particles produced following actuation of a suspension-based formulation delivered from a pressurized metered-dose inhaler (pMDI) via a nonelectrostatic valved holding chamber (VHC). It was postulated that the nonspecific nature of the particle detection system in terms of chemical composition was responsible for the inclusion of smaller non-drug-containing excipient particles in the measured size distribution data from this analyzer. This limitation may not apply to certain solution formulations in which the only particles remaining after the evaporation of propellant and volatile excipient (solubilizer) are composed of pure drug substance.
View Article and Find Full Text PDF