Background And Objectives: There is less robust data describing adverse events (AEs) in source plasma donors than in whole blood donors, particularly regarding time to AEs (TAEs). We, therefore, sought to characterize TAE and the influence of donor characteristics in a large-scale clinical trial dataset.
Materials And Methods: TAE was calculated utilizing data from the IMPACT (IMproving PlasmA CollecTion) trial, with linear regression analyses performed to determine the influence of donor parameters on TAE.
The term transfusion-related acute lung injury (TRALI) was coined in 1985 to describe acute respiratory distress syndrome (ARDS) after transfusion, when another ARDS risk factor was absent; TRALI cases were mostly associated with donor leukocyte antibody. In 2001, plasma from multiparous donors was implicated in TRALI in a randomized controlled trial in Sweden. In 2003 and in many years thereafter, the U.
View Article and Find Full Text PDFBackground: The IMPACT trial demonstrated the safety of a new personalized nomogram for plasma donation and provided an opportunity to explore short- to mid-term impact on repeat donation and deferral rates, and factors affecting these.
Study Design And Methods: In the IMPACT trial, participants were randomized to donate plasma using an established weight-based nomogram (control) versus a new personalized nomogram incorporating height, weight, and hematocrit (experimental). In this exploratory analysis, repeat donations (per donor, by study arm) were analyzed using negative binomial generalized linear regression models and descriptive statistics.
Massive bleeding remains a major source of morbidity and mortality worldwide. Recent studies have shed light on the pathophysiology of traumatic-induced coagulopathy and the central role of endotheliopathy. Transfusion therapy has changed dramatically in the last decade with use of red cells and plasma in a 1:1 ratio.
View Article and Find Full Text PDFBackground: Source plasma is essential to support the growing demand for plasma-derived medicinal products. Supply is short, with donor availability further limited by the coronavirus disease 2019 (COVID-19) pandemic. This study examined whether a novel, personalized, technology-based nomogram was noninferior with regard to significant hypotensive adverse events (AEs) in healthy donors.
View Article and Find Full Text PDFBackground: Prompt resuscitation with plasma and other blood products reduces trauma-related morbidity and mortality. Standard storage and preparation techniques for frozen plasma limit its utility in the pre-hospital setting. Plasma can be dehydrated using hot air (spray-dried plasma), stored at room temperature and rehydrated quickly for use.
View Article and Find Full Text PDFJ Gastrointest Surg
February 2020
Introduction: Autologous salvaged blood, commonly referred to as "cell saver" or "cell salvage" blood, is an important method of blood conservation. Understanding the mechanism of action and summarizing the existing evidence regarding the safety, efficiency, and the relative costs of cell salvage may help educate clinicians on how and when to best utilize autotransfusion.
Methods: This review focuses on issues concerning the quality of red blood cells (RBC), efficiency, and the cost effectiveness relative to autotransfusion.
Background: This multicenter international study evaluated electronic remote blood issue (ERBI) for blood unit collection in hospitals.
Study Design And Methods: Retrospective data were collected from the ERBI software databases and blood bank information systems. Prospective "time-and-motion" data collection methods simulated the delivery of red blood cell units to determine the staff time for each step.
Clin Hemorheol Microcirc
January 2018
Background: Small rodent models are routinely used to evaluate the safety and efficacy of blood transfusions. Limited comprehensive literature exists about effect of different storage solutions in rat red blood cells (RBCs) characteristics. RBCs undergo time dependent biochemical and biophysical changes during storage known as hypothermic storage lesions (HSLs).
View Article and Find Full Text PDFContext: - Thromboelastography (TEG) is a whole blood, real-time analyzer measuring the viscoelastic properties of the hemostasis process and allowing for individualized goal-directed therapy. However, routine use of TEG requires validation of sample storage effect on clot parameters.
Objectives: - To establish the minimum time required for equilibration time and the maximum time for sample storage for all commercially available TEG tests for the new-generation TEG 6s and to determine how those times compare with the older generation TEG 5000.
Blood transfusion is one of the most common procedures in patients in hospital so it is imperative that clinicians are knowledgeable about appropriate blood product administration, as well as the signs, symptoms, and management of transfusion reactions. In this Review, we, an international panel, provide a synopsis of the pathophysiology, treatment, and management of each diagnostic category of transfusion reaction using evidence-based recommendations whenever available.
View Article and Find Full Text PDFBackground: Massive exchange transfusion of 42-day-old red blood cells (RBCs) in a canine model of Staphylococcus aureus pneumonia resulted in in vivo hemolysis with increases in cell-free hemoglobin (CFH), transferrin-bound iron (TBI), non-transferrin-bound iron (NTBI), and mortality. We have previously shown that washing 42-day-old RBCs before transfusion significantly decreased NTBI levels and mortality, but washing 7-day-old RBCs increased mortality and CFH levels. We now report the results of altering volume, washing, and age of RBCs.
View Article and Find Full Text PDFContext: The clinical introduction of new oral anticoagulants (NOACs) has stimulated the development of tests to quantify the effects of these drugs and manage complications associated with their use. Until recently, the only treatment choices for the prevention of venous thromboembolism in orthopedic surgical patients, as well as for stroke and systemic embolism in patients with atrial fibrillation, were vitamin K antagonists, antiplatelet drugs, and unfractionated and low-molecular-weight heparins. With the approval of NOACs, treatment options and consequent diagnostic challenges have expanded.
View Article and Find Full Text PDFIn a randomized controlled blinded trial, 2-year-old purpose-bred beagles (n = 24), with Staphylococcus aureus pneumonia, were exchanged-transfused with either 7- or 42-day-old washed or unwashed canine universal donor blood (80 mL/kg in 4 divided doses). Washing red cells (RBC) before transfusion had a significantly different effect on canine survival, multiple organ injury, plasma iron, and cell-free hemoglobin (CFH) levels depending on the age of stored blood (all, P < .05 for interactions).
View Article and Find Full Text PDFBackground: Monitoring of patients' vital sign values (VSVs) during hemotherapy may have an important role in the recognition and mitigation of transfusion-associated circulatory overload (TACO). Knowledge regarding VSVs and other patient characteristics in bedside-reported TACO or fluid challenge-suspected transfusion reactions (TACO/FC-STRs) is limited.
Study Design And Methods: We performed a retrospective observational cohort study of cases of uncomplicated red blood cell (RBC) transfusions (UCTs) and reported suspected transfusion reaction (STR) cases investigated by our hospital's transfusion medicine service (TMS) from January 1, 2005, to February 29, 2008, using data obtained from TMS consult reports and quality improvement databases examining VSVs and patient characteristics in TACO/FC-STRs.
Semin Thromb Hemost
October 2010
Coagulation management requires the balancing of different components that contribute to clot formation. These components include the interactions between platelets, procoagulant, anticoagulant, and fibrinolytic factors. The cause of bleeding or thrombotic events is often multifactorial; however, the tests clinicians most frequently use to assess hemostasis do not reflect the complexity of the coagulation system.
View Article and Find Full Text PDF