Background: The Neogen® Molecular Detection Assay 2-Salmonella Enteritidis/Salmonella Typhimurium (MDA2-SE/ST) method, Performance Tested Method SM (PTM) 122302, is a nucleic acid amplification test for specific detection of Salmonella enterica ser. Enteritidis (SE) and Salmonella enterica ser. Typhimurium (ST), including the ST monophasic variant Salmonella enterica 1,4,[5],12:i:-, in select poultry samples.
View Article and Find Full Text PDFBackground: The Neogen® Molecular Detection Assay 2-Salmonella Enteritidis/Salmonella Typhimurium (MDA2-SE/ST) method is a nucleic acid amplification test for specific detection of Salmonella enterica ser. Enteritidis (SE) and Salmonella enterica ser. Typhimurium (ST), including the ST monophasic variant Salmonella enterica 1,4,[5],12:i:-, in select poultry samples.
View Article and Find Full Text PDFBackground: Reveal® 3-D for Gluten is an immunochromatographic assay for the qualitative detection of gluten in environmental samples. The test uses monoclonal antibodies reactive to prolamins in wheat.
Objective: The objective of the study was to validate the Reveal 3-D test for detection of gluten in clean-in-place rinse and swabs from a stainless steel surface.
Background: The Soleris®Enterobacteriaceae vial is a growth-based, automated method for detection of bacteria of the family Enterobacteriaceae in foods and other sample types including nutraceuticals and cosmetics. The Soleris method is used in a "dilute-to-specification" or threshold manner, in which a result is scored as positive or negative around a predetermined cutoff (in CFU/g) established by the dilution and volume of sample homogenate tested. The Soleris method was granted AOAC Performance Tested MethodSM (PTM) status for select foods after successful completion of a validation study (PTM 121901).
View Article and Find Full Text PDFBackground: Soleris® Non-Fermenting Total Viable Count (NF-TVC) is a growth-based, automated method for semiquantitative detection of aerobic, mesophilic microorganisms in foods and other consumer products such as nutraceuticals and cosmetics. The method was granted AOAC Performance Tested MethodSM status for select foods after successful completion of a validation study.
Objective: The objective of the current study was to validate the Soleris NF-TVC method for use with dried cannabis flower [>0.
Background: The Soleris® Coliform Vial is a growth-based, automated method for detection of coliform bacteria in foods and other consumer products such as nutraceuticals and cosmetics. The method was granted AOAC Performance Tested MethodSM certification for select foods after successful completion of a validation study.
Objective: The objective of the current study was to validate the Soleris coliform method for use with dried cannabis flower (>0.
Background: Soleris® Direct Yeast and Mold (DYM) is a growth-based, automated method for detection of yeast and mold in select foods and other sample types including nutraceuticals and cosmetics. The Soleris method is used in a "dilute-to-specification" or threshold manner in which a result is scored as positive or negative around a predetermined cutoff (in CFU/g) established by the dilution and volume of sample homogenate tested.
Objective: The objective of this study was to validate the method for testing of dried cannabis flower.
Background: Soleris®E. coli is an automated, growth-based method for detection and semi-quantitative determination of Escherichia coli in foods. The method can be used in dilute-to-specification (threshold) or presence/absence modes.
View Article and Find Full Text PDFBackground: Soleris®Enterobacteriaceae is a growth-based, automated method for detection of Enterobacteriaceae in food.
Objective: A study was conducted to validate the Soleris method for detection of Enterobacteriaceae in select foods (pasteurized milk, yogurt, mozzarella cheese, ice cream, dried milk, pasteurized liquid egg, frozen cooked chicken, deli ham, lettuce, and dry dog food) at a threshold of ≥ 10 CFU/g of product.
Methods: Inclusivity and exclusivity of the Soleris method were assessed by testing 55 and 38 target and non-target bacterial strains, respectively.
Background: One Broth One Plate for Salmonella (OBOP Salmonella) is a rapid and simple method for detection of Salmonella spp. in food and environmental samples using traditional culture methodology. The method utilizes single-step enrichment followed by plating to a selective/differential, chromogenic agar.
View Article and Find Full Text PDFA chemiluminescence assay using a handheld luminometer to measure the activity of alkaline phosphatase was developed that can detect 0.002% or more of unpasteurized milk in various milk products. Evaluation of the assay followed an National Conference on Interstate Milk Shipments (NCIMS)-approved protocol in which aliquots of pasteurized milk products were spiked with raw milk at various levels.
View Article and Find Full Text PDFBackground: NeoSeekTM STEC is a single-source, service-based method for detection and identification of select Shiga toxin-producing Escherichia coli (STEC), including E. coli O157:H7 and STEC of somatic groups O26, O45, O103, O111, O121, and O145. The method is a multiplex molecular method utilizing more than 80 genetic targets to identify STEC in complex matrices such as food enrichment cultures.
View Article and Find Full Text PDFBackground: Listeria Right Now™ is a novel, enrichment-free test for the detection of Listeria spp. in swab samples taken from environmental surfaces. Results are available in less than 1 h.
View Article and Find Full Text PDFRight Now is a novel, enrichment-free molecular method for detection of spp. in swab samples from environmental surfaces. The test provides results in real time, indicating the current or recent presence of spp.
View Article and Find Full Text PDFThe ANSR method is based on isothermal nucleic acid amplification technology. The modifications to assay components improve sensitivity of the assay and robustness of the internal positive control. A validation study was conducted to assess performance of a modified version of the ANSR® for O157:H7 method.
View Article and Find Full Text PDFA study was conducted to validate a minor reagent formulation change to the ANSR for Listeria method, Performance Tested MethodSM 101202. This change involves increasing the master mix volume prelyophilization by 40% and addition of salmon sperm DNA (nontarget DNA) to the master mix. These changes improve the robustness of the internal positive control response and reduce the possibility of obtaining invalid results due to weak-positive control curves.
View Article and Find Full Text PDFThe AccuPoint Advanced ATP Hygeine Monitoring System was validated by an AOAC International Performance Tested MethodSM on the detection of ATP from stainless steel surfaces. Neogen Corp.'s system is a lightweight, hand-held diagnostic tool used to validate and verify a hygiene program's effectiveness by detecting organic residues remaining on surfaces and in liquids after cleaning.
View Article and Find Full Text PDFA performance validation of the ANSR® for Campylobacter method was conducted in selected matrixes. This assay used selective nicking enzyme amplification technology to amplify target genes. Samples were enriched for 20 to 24 h and then lysed.
View Article and Find Full Text PDFA performance validation of the ANSR(®) for E. coli O157:H7 method was conducted in selected food matrixes. This assay uses selective nicking enzyme amplification technology to amplify target genes.
View Article and Find Full Text PDFA study was conducted to assess the performance of the Reveal(®) 2.0 Group D1 Salmonella lateral flow immunoassay for use in detection of Salmonella Enteritidis (SE) in raw shell eggs and poultry-associated matrixes, including chicken carcass rinse and poultry feed. In inclusivity testing, the Reveal 2.
View Article and Find Full Text PDFA study was conducted to validate minor reagent formulation, enrichment, and procedural changes to the ANSR(®) Listeria method, Performance-Tested Method(SM) 101202. In order to improve ease of use and diminish risk of amplicon contamination, the lyophilized reagent components were reformulated for increased solubility, thus eliminating the need to mix by pipetting. In the alternative procedure, an aliquot of the lysate is added to lyophilized ANSR reagents, immediately capped, and briefly mixed by vortexing.
View Article and Find Full Text PDFWork was conducted to validate performance of the ANSR(®) for Listeria monocytogenes method in selected food and environmental matrixes. This DNA-based assay involves amplification of nucleic acid via an isothermal reaction based on nicking enzyme amplification technology. Following single-step sample enrichment for 16-24 h for most matrixes, the assay is completed in 40 min using only simple instrumentation.
View Article and Find Full Text PDFANSR® Listeria was previously certified as Performance Tested Method(SM) 101202 for detection of Listeria spp. on selected environmental surfaces. This study proposes a matrix extension to the method for detection of Listeria spp.
View Article and Find Full Text PDFHere we describe results of a study to validate minor reagent formulation changes to the Soleris Direct Yeast and Mold (DYM) automated growth-based method for semi-quantitative detection of yeast and mold in food products. In order to reduce the maximum concentration of the selective agent chloramphenicol in the Soleris reagents, chloramphenicol was removed from the selective supplement and added to the vial growth medium itself. Therefore, both the vial medium and supplement have been reformulated in an alternative version of the method.
View Article and Find Full Text PDF