In fiber-reinforced polymer composites, the fiber-matrix interface controls stress transfer mechanisms, thereby affecting mechanical performance. Interfacial properties are often extracted via single-fiber composite tests. In these tests, the load is transferred from the polymer to the fiber through interfacial shear stresses, necessitating the evaluation of interfacial shear properties.
View Article and Find Full Text PDFThe morphology and architecture of structures formed by sediment-dwelling invertebrates, such as excavations or burrows, are often assumed to be characteristic of a given species, consistent across a range of environmental conditions, and used to categorise species contributions to ecosystem functioning. However, very few investigations use non-invasive high-resolution techniques capable of determining fine scale variations in burrow form and complexity, or consider whether or not the form of the burrow is context dependent. Here, we provide replicate high-resolution micro-focus computed tomography data for the complete burrow systems of the Opheliid polychaete, Armandia cirrhosa, across a range of salinity and habitat conditions.
View Article and Find Full Text PDFN95/FFP3 respirators have been critical to protect healthcare workers and their patients from the transmission of COVID-19. However, these respirators are characterised by a limited range of size and geometry, which are often associated with fitting issues in particular sub-groups of gender and ethnicities. This study describes a novel methodology which combines magnetic resonance imaging (MRI) of a cohort of individuals (n = 8), with and without a respirator in-situ, and 3D registration algorithm which predicted the goodness of fit of the respirator.
View Article and Find Full Text PDFAdvanced manufacturing technologies, led by additive manufacturing, have undergone significant growth in recent years. These technologies enable engineers to design parts with reduced weight while maintaining structural and functional integrity. In particular, metal additive manufacturing parts are increasingly used in application areas such as aerospace, where a failure of a mission-critical part can have dire safety consequences.
View Article and Find Full Text PDFSARS-CoV-2 infection is a global pandemic. Personal Protective Equipment (PPE) to protect healthcare workers has been a recurrent challenge in terms of global stocks, supply logistics and suitability. In some settings, around 20% of healthcare workers treating COVID-19 cases have become infected, which leads to staff absence at peaks of the pandemic, and in some cases mortality.
View Article and Find Full Text PDFThe survivorship of cementless orthopaedic implants may be related to their initial stability; insufficient press-fit can lead to excessive micromotion between the implant and bone, joint pain, and surgical revision. However, too much interference between implant and bone can produce excessive strains and damage the bone, which also compromises stability. An understanding of the nature and mechanisms of strain generation during implantation would therefore be valuable.
View Article and Find Full Text PDFPersonalised prosthetic sockets are fabricated by expert clinicians in a skill- and experience-based process, with research providing tools to support evidence-based practice. We propose that digital volume correlation (DVC) may offer a deeper understanding of load transfer from prosthetic sockets into the residual limb, and tissue injury risk. This study's aim was to develop a transtibial amputated limb analogue for volumetric strain estimation using DVC, evaluating its ability to distinguish between socket designs.
View Article and Find Full Text PDFBacterial infections of central venous catheters (CVCs) cause much morbidity and mortality, and are usually diagnosed by concordant culture of blood and catheter tip. However, studies suggest that culture often fails to detect biofilm bacteria. This study optimizes X-ray micro-focus computed tomography (X-ray µCT) for the quantification and determination of distribution and heterogeneity of biofilms in in vitro CVC model systems.
View Article and Find Full Text PDFIn idiopathic pulmonary fibrosis (IPF), the fibroblast focus is a key histological feature representing active fibroproliferation. On standard 2D pathologic examination, fibroblast foci are considered small, distinct lesions, although they have been proposed to form a highly interconnected reticulum as the leading edge of a "wave" of fibrosis. Here, we characterized fibroblast focus morphology and interrelationships in 3D using an integrated micro-CT and histological methodology.
View Article and Find Full Text PDFThe architecture of biogenic structures can be highly influential in determining species contributions to major soil and sediment processes, but detailed 3-D characterisations are rare and descriptors of form and complexity are lacking. Here we provide replicate high-resolution micro-focus computed tomography (μ-CT) data for the complete burrow systems of three co-occurring, but functionally contrasting, sediment-dwelling inter-tidal invertebrates assembled alone, and in combination, in representative model aquaria. These data (≤ 2,000 raw image slices aquarium(-1), isotropic voxel resolution, 81 μm) provide reference models that can be used for the development of novel structural analysis routines that will be of value within the fields of ecology, pedology, geomorphology, palaeobiology, ichnology and mechanical engineering.
View Article and Find Full Text PDFHydrothermal vents in the Southern Ocean are the physiologically most isolated chemosynthetic environments known. Here, we describe Kiwa tyleri sp. nov.
View Article and Find Full Text PDFBackground: Understanding the three-dimensional (3-D) micro-architecture of lung tissue can provide insights into the pathology of lung disease. Micro computed tomography (µCT) has previously been used to elucidate lung 3D histology and morphometry in fixed samples that have been stained with contrast agents or air inflated and dried. However, non-destructive microstructural 3D imaging of formalin-fixed paraffin embedded (FFPE) tissues would facilitate retrospective analysis of extensive tissue archives of lung FFPE lung samples with linked clinical data.
View Article and Find Full Text PDFPliosaurs were among the largest predators in Mesozoic seas, and yet their functional anatomy and feeding biomechanics are poorly understood. A new, well-preserved pliosaur from the Kimmeridgian of Weymouth Bay (UK) revealed cranial adaptations related to feeding. Digital modelling of computed tomography scans allowed reconstruction of missing, distorted regions of the skull and of the adductor musculature, which indicated high bite forces.
View Article and Find Full Text PDFPliosaurs were a long-lived, ubiquitous group of Mesozoic marine predators attaining large body sizes (up to 12 m). Despite much being known about their ecology and behaviour, the mechanisms they adopted for prey detection have been poorly investigated and represent a mystery to date. Complex neurovascular systems in many vertebrate rostra have evolved for prey detection.
View Article and Find Full Text PDFAcoustic emission (AE) is a non-destructive technique that is capable of passively monitoring failure of a construct with excellent temporal resolution. Previous investigations using AE to monitor the integrity of a total hip replacement (THR) have used surface mounted sensors; however, the AE signal attenuates as it travels through materials and across interfaces. This study proposes that directly embedded sensors within the femoral stem of the implant will reduce signal attenuation effects and eliminate potential complications and variability associated with fixing the sensor to the sample.
View Article and Find Full Text PDFJ Biomed Mater Res B Appl Biomater
July 2009
To improve the longevity of total hip replacements, techniques such as vacuum mixing have been developed to reduce the amount of porosity within the cement. However, data from the Swedish hip registry has demonstrated an increased risk of revision for vacuum-mixed cemented devices in the first 5 years postoperatively. Theoretical and experimental evidence suggests that stresses induced by cement shrinkage during polymerization alone are sufficient to induce cracking.
View Article and Find Full Text PDF