Publications by authors named "Mark Lehmkuhle"

Epitel has developed Epilog, a miniature, wireless, wearable electroencephalography (EEG) sensor. Four Epilog sensors are combined as part of Epitel's Remote EEG Monitoring platform (REMI) to create 10 channels of EEG for remote patient monitoring. REMI is designed to provide comprehensive spatial EEG recordings that can be administered by non-specialized medical personnel in any medical center.

View Article and Find Full Text PDF

Objective: Recording seizures using personal seizure diaries can be challenging during everyday life and many seizures are missed or mis-reported. People living with epilepsy could benefit by having a more accurate and objective wearable EEG system for counting seizures that can be used outside of the hospital. The objective of this study was to (1) determine which seizure types can be electrographically recorded from the scalp below the hairline, (2) determine epileptologists' ability to identify electrographic seizures from single-channels extracted from full-montage wired-EEG, and (3) determine epileptologists' ability to identify electrographic seizures from Epilog, a wireless single-channel EEG sensor.

View Article and Find Full Text PDF

The motor cortex and subthalamic nucleus (STN) of patients with Parkinson's disease (PD) exhibit abnormally high levels of electrophysiological oscillations in the ~12-35 Hz beta-frequency range. Recent studies have shown that beta is partly carried forward to regulate future motor states in the healthy condition, suggesting that steady state beta power is lower when a sequence of movements occurs in a short period of time, such as during fast gait. However, whether this relationship between beta power and motor states persists upon parkinsonian onset or in response to effective therapy is unclear.

View Article and Find Full Text PDF

Objective: Common data elements (CDEs) are currently unavailable for mobile health (mHealth) in epilepsy devices and related applications. As a result, despite expansive growth of new digital services for people with epilepsy, information collected is often not interoperable or directly comparable. We aim to correct this problem through development of industry-wide standards for mHealth epilepsy data.

View Article and Find Full Text PDF

Exposure to nerve agents (NAs) and other organophosphates (OPs) can initiate seizures that rapidly progress to status epilepticus (SE). While the electrographic and neuropathological sequelae of SE evoked by NAs and OPs have been characterized in adult rodents, they have not been adequately investigated in immature animals. In this study postnatal day (PND) 14, 21 and 28 rat pups, along with PND70 animals as adult controls, were exposed to NAs (sarin, VX) or another OP (diisopropylfluorophosphate, DFP).

View Article and Find Full Text PDF

Many progressive neurologic diseases in humans, such as epilepsy, require pre-clinical animal models that slowly develop the disease in order to test interventions at various stages of the disease process. These animal models are particularly difficult to implement in immature rodents, a classic model organism for laboratory study of these disorders. Recording continuous EEG in young animal models of seizures and other neurological disorders presents a technical challenge due to the small physical size of young rodents and their dependence on the dam prior to weaning.

View Article and Find Full Text PDF

Objective: Cortical electrical stimulation (CES) has been used extensively in experimental neuroscience to modulate neuronal or behavioral activity, which has led this technique to be considered in neurorehabilitation. Because the cortex and the surrounding anatomy have irregular geometries as well as inhomogeneous and anisotropic electrical properties, the mechanism by which CES has therapeutic effects is poorly understood. Therapeutic effects of CES can be improved by optimizing the stimulation parameters based on the effects of various stimulation parameters on target brain regions.

View Article and Find Full Text PDF

Background: Cortical electrical stimulation (CES) techniques are practical tools in neurorehabilitation that are currently being used to test models of functional recovery after neurologic injury. However, the mechanisms by which CES has therapeutic effects, are not fully understood.

Objective: In this study, we investigated the effects of CES on unit activity of different neuronal elements in layers of rat primary motor cortex after the offset of stimulation.

View Article and Find Full Text PDF
Article Synopsis
  • Researchers are exploring closed-loop neural interface technology to enhance deep brain stimulation, prosthetics, and epilepsy treatments using neural decoding and electrical stimulation feedback.
  • In a rat study, three subjects were trained to control motor activity in response to visual cortex stimulation for food rewards, using feedback to gauge their performance.
  • The outcome underscores the potential of this model for advancing closed-loop neural device technology by providing direct feedback on brain activity during tasks.
View Article and Find Full Text PDF