Importance: The effectiveness and safety of computed tomography (CT) and invasive coronary angiography (ICA) in different age groups is unknown.
Objective: To determine the association of age with outcomes of CT and ICA in patients with stable chest pain.
Design, Setting, And Participants: The assessor-blinded Diagnostic Imaging Strategies for Patients With Stable Chest Pain and Intermediate Risk of Coronary Artery Disease (DISCHARGE) randomized clinical trial was conducted between October 2015 and April 2019 in 26 European centers.
Smoking cessation is the most effective intervention to reduce mortality in patients with established atherosclerotic cardiovascular disease (ASCVD), with 'e-cigarettes' becoming an increasingly used intervention to achieve smoking cessation. The current review aims to summarise the current evidence base for their efficacy and safety in the ASCVD cohort. A search of the PUBMED and MEDLINE databases using the terms 'e-cigarette', 'cessation', 'safety' and 'efficacy' since 2012 yielded 706 results.
View Article and Find Full Text PDFBackground: Deformation imaging represents a method of measuring myocardial function, including global longitudinal strain (GLS), peak atrial longitudinal strain (PALS) and radial strain. This study aimed to assess subclinical improvements in left ventricular function in patients undergoing transcatheter aortic valve implantation (TAVI) by comparing GLS, PALS and radial strain pre and post procedure.
Methods: We conducted a single site prospective observational study of 25 patients undergoing TAVI, comparing baseline and post-TAVI echocardiograms.
Background: Despite the increased uptake of intravascular lithotripsy (IVL) for treating severely calcified coronary lesions, there is limited patient-level data examining the effect of IVL on quality of life, symptomatology, and outcomes beyond 30 days. We sought to assess demographics, procedural characteristics, outcomes, and impact of IVL on patient-reported angina after a minimum of 6 months follow-up.
Methods: A retrospective single-center study was conducted of patients treated with coronary IVL between January and October 2020.
Background: In the diagnosis of obstructive coronary artery disease (CAD), computed tomography (CT) is an accurate, noninvasive alternative to invasive coronary angiography (ICA). However, the comparative effectiveness of CT and ICA in the management of CAD to reduce the frequency of major adverse cardiovascular events is uncertain.
Methods: We conducted a pragmatic, randomized trial comparing CT with ICA as initial diagnostic imaging strategies for guiding the treatment of patients with stable chest pain who had an intermediate pretest probability of obstructive CAD and were referred for ICA at one of 26 European centers.
Transcatheter aortic valve implantation and implantation of other transcatheter heart valves, generally requires insertion of a temporary venous pacemaker. Implantation of a temporary venous pacemaker adds complexity, time and risk to the procedure. Guidewire modification to allow pacing is increasingly popular, however it requires technical expertise and provides unipolar pacing resulting in high thresholds and potential capture loss.
View Article and Find Full Text PDFGrowing clinical data support the use of transcatheter therapies for significant mitral valve disease. Currently, edge-to-edge repair is the transcatheter treatment of choice, but many anatomies are not suitable. Transcatheter mitral valve replacement offers several potential advantages over transcatheter repair, most notably a greater and more sustained reduction in mitral regurgitation post-implantation, but also potential disadvantages.
View Article and Find Full Text PDFObjectives: The purpose of this observational first-in-human experience was to investigate the feasibility and safety of the EVOQUE tricuspid valve replacement system and its impact on short-term clinical outcomes.
Background: Transcatheter tricuspid intervention is a promising option for selected patients with severe tricuspid regurgitation (TR). Although transcatheter leaflet repair is an option for some, transcatheter tricuspid valve replacement (TTVR) may be applicable to a broader population.
JACC Cardiovasc Interv
October 2020
Objectives: The aim of this study was to examine the initial experience with a novel transseptal transcatheter mitral valve replacement (TMVR) system.
Background: Transseptal TMVR may offer a less invasive option than surgery for mitral regurgitation (MR) with greater efficacy and fewer anatomic limitations than transcatheter repair.
Methods: Patients were treated with the EVOQUE TMVR system from September 2018 to October 2019.
Objectives: The authors report the CLASP (Edwards PASCAL Transcatheter Mitral Valve Repair System Study) expanded experience, 1-year outcomes, and analysis by functional mitral regurgitation (FMR) and degenerative mitral regurgitation (DMR).
Background: The 30-day results from the CLASP study of the PASCAL transcatheter valve repair system for clinically significant mitral regurgitation (MR) have been previously reported.
Methods: Eligible patients had symptomatic MR ≥3+, were receiving optimal medical therapy, and were deemed candidates for transcatheter mitral repair by the local heart team.
An amendment to this paper has been published and can be accessed via the original article.
View Article and Find Full Text PDFBackground: Health-related quality of life (HRQoL) is impaired in patients with stable angina but patients often present with other forms of chest pain. The aim of this study was to compare the pre-diagnostic HRQoL in patients with suspected coronary artery disease (CAD) according to angina type, gender, and presence of obstructive CAD.
Methods: From the pilot study for the European DISCHARGE trial, we analysed data from 24 sites including 1263 patients (45.
The original version of this article, published on 16 December 2019, unfortunately contained two mistakes.
View Article and Find Full Text PDFBackground: Transcatheter aortic valve replacement (TAVR) use is increasing in patients with longer life expectancy, yet robust data on the durability of transcatheter heart valves (THVs) are limited. Redo-TAVR may play a key strategy in treating patients in whom THVs fail.
Objectives: The authors sought to examine outcomes following redo-TAVR.
Objectives: To assess the safety and efficacy of the Wattson temporary pacing guidewire.
Background: Transcatheter aortic valve replacement (TAVR) requires a guidewire for device delivery and generally requires temporary pacing wire for burst and back-up pacing. The Wattson wire provides concomitant support and bipolar pacing without the need to place a temporary venous pacemaker (TVP).
Objectives: The aim of this study was to examine the effect of different transcatheter heart valves (THVs) on valve leaflet displacement when deployed within bioprosthetic surgical valves and, thereby, risk for coronary obstruction.
Background: Coronary obstruction is a potentially devastating complication during valve-in-valve (ViV) transcatheter aortic valve replacement. Strategies such as provisional stenting and intentional bioprosthetic valve leaflet laceration have been developed to mitigate this risk.
Objectives: The aim of this study was to report the 1-year results of transcatheter aortic valve replacement (TAVR) with the Edwards SAPIEN 3 (S3) valve in extremely large annuli.
Background: Favorable 30-day outcomes of S3 TAVR in annuli >683 mm have previously been reported. Pacemaker implantation rates were acceptable, and a larger left ventricular outflow tract and more eccentric annular anatomy were associated with increasing paravalvular leak.
Objective: To implement detailed EU cardiac computed tomography angiography (CCTA) quality criteria in the multicentre DISCHARGE trial (FP72007-2013, EC-GA 603266), we reviewed image quality and adherence to CCTA protocol and to the recommendations of invasive coronary angiography (ICA) in a pilot study.
Materials And Methods: From every clinical centre, imaging datasets of three patients per arm were assessed for adherence to the inclusion/exclusion criteria of the pilot study, predefined standards for the CCTA protocol and ICA recommendations, image quality and non-diagnostic (NDX) rate. These parameters were compared via multinomial regression and ANOVA.
Aims: The commonly used valve-in-valve (VIV) app recommends sizing based on dimensions of both the transcatheter heart valve (THV) and bioprosthetic surgical valve. The implications of hydrodynamic testing to guide VIV sizing are poorly understood. This bench study assessed the hydrodynamic performance of different sizes of self-expanding supra-annular THVs in three different surgical aortic bioprostheses at different implantation depths.
View Article and Find Full Text PDF