Publications by authors named "Mark E Gittins"

Context: A 25-pound weight limit is currently set on containerized instrumentation sets by the Association of periOperative Registered Nurses (AORN) and the Association for the Advancement of Medical Instrumentation (AAMI), in order to reduce strain on the staff and ensure that the sets are not too crowded in order to preserve sterilization and drying of the instruments. This is pushing companies to reduce the weight and number of instrumentation sets for the operating room. One solution has been to explore the viability of new, lighter materials such as Onyx.

View Article and Find Full Text PDF

Context: With the growing number of robotic knee arthroplasties being performed, new outcomes must be analyzed to provide a database for comparing robotic and nonrobotic surgeries. These results can be utilized in the future to properly assess the significance of utilizing robotic technology in the operating room regarding patient outcomes and cost.

Objectives: The aims of this study are to: (1) analyze adverse outcomes from robotic-assisted knee arthroplasty and its relation to sex, body mass index (BMI), and age; and (2) explore any possible differences in outcomes among robotic-assisted unicompartmental knee arthroplasty (UKA) and robotic-assisted total knee arthroplasty (TKA).

View Article and Find Full Text PDF

One of the primary aims of total knee arthroplasty (TKA) is restoration of the mechanical axis of the lower limb. Maintenance of the mechanical axis within 3° of neutral has been shown to result in improved clinical results and implant longevity. Handheld image-free robotic-assisted total knee arthroplasty (HI-TKA) is a novel way of performing TKA in the era of modern robotic-assisted TKA.

View Article and Find Full Text PDF

A unique case is described involving the arthroscopic removal of a bullet in the wall of the acetabulum from a low-velocity gunshot wound. The projectile entered the abdomen anteriorly and penetrated the urinary bladder and the inner wall of the acetabulum before becoming embedded intra-articularly in the subchondral bone of the hip joint. After surgical repair of the viscus, the bullet was retrieved from the hip joint using standard arthroscopic portals and a fracture table.

View Article and Find Full Text PDF

Approximately a century ago, labral avulsion from the glenoid was described as a source of recurrent anterior shoulder dislocation. Since then, the significance of other origins of shoulder instability has been a controversial issue. Cadaveric dissection, biomechanical evaluation, and surgical observation have led to the discovery of additional pathologic conditions associated with glenohumeral instability that must be properly identified and addressed for operative success.