Introduction: Central aortic pressure waveform analyses can provide clinically relevant information beyond conventional brachial blood pressure (BP) assessment. This waveform can be reproduced noninvasively through application of a generalized transfer function (GTF) on a peripheral waveform, as conventionally performed by applanation tonometry. Photoplethysmography (PPG) is an alternate approach; however, differences in measurement site and modality demand the use of a transfer function (TF) specific for those differences.
View Article and Find Full Text PDFMost non-invasive blood pressure (BP) measurements are carried out using instruments which implement either the Ratio or the Maximum Gradient oscillometric method, mostly during cuff deflation, but more rarely during cuff inflation. Yet, there is little published literature on the relative advantages and accuracy of these two methods. In this study of 40 lightly sedated individuals aged 64.
View Article and Find Full Text PDFThere is little quantitative clinical data available to support blood pressure measurement accuracy during cuff inflation. In this study of 35 male and 5 female lightly anaesthetized subjects aged 64.1 ± 9.
View Article and Find Full Text PDFCardiovascular disease is the number 1 cause of death globally, with elevated blood pressure (BP) being the single largest risk factor. Hence, BP is an important physiological parameter used as an indicator of cardiovascular health. Noninvasive cuff-based automated monitoring is now the dominant method for BP measurement and irrespective of whether the oscillometric or the auscultatory method is used, all are calibrated according to the Universal Standard (ISO 81060-2:2019), which requires two trained operators to listen to Korotkoff K1 sounds for SBP and K4/K5 sounds for DBP.
View Article and Find Full Text PDFConventional sphygmomanometry with cuff deflation is used to calibrate all noninvasive BP (NIBP) instruments and the International Standard makes no mention of calibrating methods specifically for NIBP instruments, which estimate systolic and diastolic pressure during cuff inflation rather than cuff deflation. There is however increasing interest in inflation-based NIBP (iNIBP) instruments on the basis of shorter measurement time, reduction in maximal inflation pressure and improvement in patient comfort and outcomes. However, we have previously demonstrated that SBP estimates based on the occurrence of the first K1 Korotkoff sounds during cuff deflation can underestimate intra-arterial SBP (IA-SBP) by an average of 14 ± 10 mmHg.
View Article and Find Full Text PDFObjective: Development and testing of cuffless blood pressure (BP) devices requires methods to increase and decrease BP. This is also required by cuffless BP validation standards. Pharmacological interventions, whilst successful, are not always feasible for all subpopulations or research settings.
View Article and Find Full Text PDFObjective: Aortic pressure estimation requires reliable peripheral pulse waveform acquisition. The peripheral waveform can change with local vascular effects that can be independent of aortic pressure. This study quantifies the effects of peripheral vasculature changes on radial and brachial waveforms.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2023
Objective: Aortic (central) pressure features are associated with cardiovascular complications and can be algorithmically derived from non-invasive peripheral arterial waveforms. This has conventionally been performed with a pressure waveform (i.e.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2023
Baroreceptors, sensors that play a role in controlling arterial blood pressure (BP), are mechanical stretch receptors located in the aortic arch and carotid sinuses. Factors affecting the degree of stretch in the vessel wall with BP, such as increased arterial stiffness, may compromise baroreceptor sensitivity (BRS) to BP changes. Yet, evidence of this is scattered, as both baroreceptor sensitivity (BRS) and arterial stiffness are calculated variables with multiple methodological approaches.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2023
Noninvasive blood pressure (NIBP) devices are calibrated against validated auscultation sphygmomanometers using Korotkoff sounds. This study aimed to investigate the timing of Korotkoff sounds in relation to pulse appearance in the brachial artery and values of intra-arterial blood pressure. Experiments were carried out on 15 participants, (14 males, 64.
View Article and Find Full Text PDFNanosensors are nanoscale devices that measure physical attributes and convert these signals into analyzable information. In preparation, for the impending reality of nanosensors in clinical practice, we confront important questions regarding the evidence supporting widespread device use. Our objectives are to demonstrate the value and implications for new nanosensors as they relate to the next phase of remote patient monitoring and to apply lessons learned from digital health devices through real-world examples.
View Article and Find Full Text PDFThe global health burden presented by hypertension is providing increased motivation for improved means of collection of blood pressure (BP) data. A growing area of research and commercial activity is the use of wearable devices to provide BP data using non-invasive cuffless techniques. The accelerated progress in recent years, particularly relating to connectivity of smartphone technology, has promoted the availability of consumer devices that provide values of BP.
View Article and Find Full Text PDFPurpose: Anemia and red cell transfusion contribute to morbidity and mortality of surgery. The concept of patient blood management to mitigate preoperative anemia, optimize coagulation, conserve red cells intraoperatively and accept lower post-operative transfusion thresholds has recently gained widespread acceptance across a range of surgical disciplines. Fluid administration is likely to contribute significantly to perioperative anemia and red-cell transfusion requirements, yet a robust basis for managing fluid administration in this context has not been articulated.
View Article and Find Full Text PDFAutomated 'oscillometric' blood pressure (BP) measuring devices (BPMDs) were developed in the 1970s to replace manual auscultatory BP measurement by mercury sphygmomanometer. Automated BPMDs that have passed accuracy testing versus a reference auscultatory sphygmomanometer using a scientifically accepted validation protocol are recommended for clinical use globally. Currently, there are many thousands of unique automated BPMDs manufactured by hundreds of companies, with each device using proprietary algorithms to estimate BP and using a method of operation that is largely unchanged since inception.
View Article and Find Full Text PDFBrain arteriovenous malformation (bAVM) resection imposes several post-operative clinical challenges including intracranial haemorrhage (ICH). Daily non-invasive monitoring of haemodynamic measurements may be useful in predicting post-operative ICH. This prospective study used transcranial colour duplex (TCCD) and central aortic pressure (CAP) measurements to evaluate 15 bAVM patients pre-operatively and daily ≤ 14 days post-operatively.
View Article and Find Full Text PDFBackground: The association between arterial stiffness and cardiovascular risk in CKD and ESRD patients is well established. However, the relationship between renal function estimation and properties of large arteries is unclear due to the four different methods used to quantify glomerular filtration. This study investigated the relationship between carotid-femoral pulse wave velocity (c-fPWV), as a measure of arterial stiffness, and accepted metrics of renal function.
View Article and Find Full Text PDFComput Methods Programs Biomed
May 2022
Background And Objectives: Stroke volume (SV) and cardiac output (CO) are the key indicators for the evaluation of cardiac function and hemodynamic status during the perioperative period, which are very important in the detection and treatment of cardiovascular diseases. Traditional CO and SV measurement methods have problems such as complex operation, low precision and poor generalization ability.
Methods: In this paper, a method for estimating stroke volume based on cascade artificial neural network (ANN) and time domain features of radial pulse waveform (SV) was proposed.
Objective: Aim of this study was to evaluate the associations of non-invasive central aortic and peripheral (brachial) blood pressure (BP) for Hypertension-mediated organ damage (HMOD) and atherosclerotic cardiovascular disease (ASCVD) risk.
Methods: We evaluated associations of HMOD with 24-h ambulatory blood pressure monitoring (ABPM) of central aortic and peripheral BP indices in patients with primary hypertension and presence of several cardiovascular risk factors. BP measurements were performed by means of a non-invasive automated oscillometric device (Mobil-O-Graph).
Orthostatic intolerance (OI) is frequently reported in young women with generalized hypermobility spectrum disorder (G-HSD) and hypermobile EDS (hEDS). However, it remains currently unclear whether OI is a comorbidity or fundamental part of the pathophysiology of G-HSD or hEDS. This study investigated the prevalence and impact of OI in young women across the hypermobility spectrum.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
November 2021
Background: The use of wearable cuffless blood pressure (BP) devices is becoming commercially prevalent with little published validation information. Most devices rely, at least in part, on the relationship between pulse arrival time (PAT) and BP, a theoretical fundamental relationship that was first commercially exploited in 1993 with the release of the Casio BP-100 digital watch.
Objective: This study explored the PAT method of BP estimation in a commercial device where it first began, the Casio BP-100 (Model No.
Annu Int Conf IEEE Eng Med Biol Soc
November 2021
Background: Pulse transit time (PTT) and pulse arrival time (PAT) are promising measures for cuffless arterial blood pressure (BP) estimation given the intrinsic arterial stiffness-BP relationship. However, arterial stiffness (and PTT) is altered by autonomically-driven smooth muscle tension changes, potentially independent of BP. This would limit PTT or PAT as accurate BP correlates, more so in resistance vessels than conductance arteries.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
November 2021
Background: Non-contact measurement of physiological vital signs, such as blood pressure (BP), by video-based photoplethysmography (vPPG) is a potential means for remote health monitoring. However, the signal-to-noise ratio of cardiovascular signals within the vPPG is very low.
Objective: This study investigates the potential of BP estimation from vPPG.
Isolated systolic hypertension in the young (ISHY) remains a challenging problem, partly due to the differences in central aortic pressure observed in studies investigating ISHY. The fundamental relationship between heart rate and central aortic pressure, and more precisely, the relationship between heart rate and amplification of central aortic pressure in the periphery, underpins the assessment and, as a consequence, the treatment of ISHY. Physiology warrants that an increase in heart rate would lead to increased amplification of the pressure pulse between the aorta and the brachial artery.
View Article and Find Full Text PDFIt is well known that non-invasive blood pressure measurements significantly underestimate true systolic blood pressure (SBP), and overestimate diastolic blood pressure (DBP). The aetiology for these errors has not yet been fully established. This study aimed to investigate the accuracy of Korotkoff sounds for detection of SBP and DBP points as used in brachial cuff sphygmomanometry.
View Article and Find Full Text PDF