Publications by authors named "Mark A Hayes"

There is tantalizing evidence that proteins can be accurately and selectively manipulated by higher order electric field effects within microfluidic devices. The accurate and precise manipulation of proteins in these platforms promises to disrupt and revolutionize many fields, most notably analytical biochemistry. Several lines of experimental evidence suggest much higher forces are generated compared to those calculated from traditional theories and those higher forces arise from subtle structural features of the proteins providing selectivity.

View Article and Find Full Text PDF

Filters with high throughput, minimal dead volume, and greater sensitivity to particle size are needed, which traditional benchtop filtration cannot provide. Leveraging microfabrication techniques developed by the electronics and optics industries, the filters presented here feature a unique serpentine "NanoRidge" structure, offering a continuous filtration gap spanning over three meters on a compact 4 × 14.5 mm footprint.

View Article and Find Full Text PDF

Organelle heterogeneity and inter-organelle contacts within a single cell contribute to the limited sensitivity of current organelle separation techniques, thus hindering organelle subpopulation characterization. Here, we use direct current insulator-based dielectrophoresis (DC-iDEP) as an unbiased separation method and demonstrate its capability by identifying distinct distribution patterns of insulin vesicles from INS-1E insulinoma cells. A multiple voltage DC-iDEP strategy with increased range and sensitivity has been applied, and a differentiation factor (ratio of electrokinetic to dielectrophoretic mobility) has been used to characterize features of insulin vesicle distribution patterns.

View Article and Find Full Text PDF

Determining the physical and chemical properties of biologically important particles such as cells, organelles, viruses, exosomes, complexes, nucleotides, and proteins is needed to understand their function. These properties are determined with common analytical tools (mass spectrometry, cryo-EM, NMR, various spectroscopies, nucleotide sequencing, etc.) whose function can be improved when samples are pure and concentrated.

View Article and Find Full Text PDF

The development of elegant and numerous microfluidic manipulations has enabled significant advances in the processing of small volume samples and the detection of minute amounts of biomaterials. Effective isolation of single cells in a defined volume as well as manipulations of complex bioparticle or biomolecule mixtures allows for the utilization of information-rich detection methods including mass spectrometry, electron microscopy imaging, and amplification/sequencing. The art and science of translating biosamples from microfluidic platforms to highly advanced, information-rich detection system is the focus of this review, where we term the translation between the microfluidics elements to the external world "off-chipping.

View Article and Find Full Text PDF

Proteins are perhaps the most important yet frustratingly complicated and difficult class of compounds to analyze, manipulate, and use. One very attractive option to characterize and differentially concentrate proteins is dielectrophoresis, but according to accepted theory, the force on smaller particles the size of proteins is too low to overcome diffusive action. Here, three model proteins, immunoglobulin G, α-chymotrypsinogen A, and lysozyme, are shown to generate forces much larger than predicted by established theory are more consistent with new theoretical constructs, which include the dipole moment and interfacial polarizability.

View Article and Find Full Text PDF

The ability to selectively move and trap proteins is core to their effective use as building blocks and for their characterization. Analytical and preparative strategies for proteins have been pursued and modeled for nearly a hundred years, with great advances and success. Core to all of these studies is the separation, isolation, purification, and concentration of pure homogeneous fractions of a specific protein in solution.

View Article and Find Full Text PDF

is an important pathogen and is a world-wide threat to food safety and public health. Surveillance of serotypes and fundamental biological and biochemical studies are supported by a wide variety of established and emerging bioanalytical techniques. These include classic serotyping based on the nomenclature and the emerging whole genome sequencing strategy.

View Article and Find Full Text PDF

Differentiating bacteria strains using biophysical forces has been the focus of recent studies using dielectrophoresis (DEP). The refinement of these studies has created high-resolution separations such that very subtle properties of the cells are enough to induce significant differences in measurable biophysical properties. These high-resolution capabilities build upon the advantages of DEP which include small sample sizes and fast analysis times.

View Article and Find Full Text PDF

A central challenge in measuring the biophysical properties of cells with electrokinetic approaches is the assignment of these biophysical properties to specific biological characteristics. Changes in the electrokinetic behavior of cells may come from mutations, altered gene expression levels, post-translation modifications, or environmental effects. Here we assess the electrokinetic behavior of chemically surface-modified bacterial cells in order to gain insight into the biophysical properties that are specifically affected by changes in surface chemistry.

View Article and Find Full Text PDF

Transmission electron microscopy (TEM) of biological samples has a long history and has provided many important insights into fundamental processes and diseases. While great strides have been made in EM data collection and data processing, sample preparation is still performed using decades-old techniques. Those sample preparation methods rely on extensive macroscale purification and concentration to achieve homogeneity suitable for high-resolution analyses.

View Article and Find Full Text PDF

Electrochemically modulated liquid chromatography (EMLC) uses electrical potentials, applied to a conductive chromatographic stationary phase (e.g., porous graphitic carbon [PGC]), to manipulate analyte retention.

View Article and Find Full Text PDF

Neural stem and progenitor cells (NSPCs) are an extremely important group of cells that form the central nervous system during development and have the potential to repair damage in conditions such as stroke impairment, spinal cord injury and Parkinson's disease degradation. Current schemes for separation of NSPCs are inadequate due to the complexity and diversity of cells in the population and lack sufficient markers to distinguish diverse cell types. This study presents an unbiased high-resolution separation and characterization of NSPC subpopulations using direct current insulator-based dielectrophoresis (DC-iDEP).

View Article and Find Full Text PDF

Foodborne pathogens pose one of the greatest challenges facing public health in the modern day. One important pathogen, Listeria monocytogenes, is known to be challenging to detect and identify. Three serovars cause most of the Listeria related food-borne illnesses, which the Centers for Disease Control currently utilizes a combination of pulsed-field gel electrophoresis and whole genome sequencing for identification and the determination of clusters and outbreaks.

View Article and Find Full Text PDF

The development and expansion of wind energy is considered a key global threat to bat populations. Bat carcasses are being found underneath wind turbines across North and South America, Eurasia, Africa, and the Austro-Pacific. However, relatively little is known about the comparative impacts of techniques designed to modify turbine operations in ways that reduce bat fatalities associated with wind energy facilities.

View Article and Find Full Text PDF

Dielectrophoresis (DEP) brings about the high-resolution separations of cells and other bioparticles arising from very subtle differences in their properties. However, an unanticipated limitation has arisen: difficulty in assignment of specific biological features which vary between two cell populations. This hampers the ability to interpret the significance of the variations.

View Article and Find Full Text PDF

Electrophoretic exclusion (EE) is a counterflow gradient technique that exploits hydrodynamic flow and electrophoretic forces to exclude, enrich, and separate analytes. Resolution for this technique has been theoretically examined and the smallest difference in electrophoretic mobilities that can be completely separated is estimated to be 10  cm /Vs. Traditional and mesoscale systems have been used, whereas microfluidics offers a greater range of geometries and configurations towards approaching this theoretical limit.

View Article and Find Full Text PDF

Invasive reptilian predators can have substantial impacts on native species and ecosystems. Tegu lizards are widely distributed in South America east of the Andes, and are popular in the international live animal trade. Two species are established in Florida (U.

View Article and Find Full Text PDF

Common vampire bats (Desmodus rotundus) occur throughout much of South America to northern México. Vampire bats have not been documented in recent history in the United States, but have been documented within about 50 km of the U.S.

View Article and Find Full Text PDF

Blood is one of the most important biofluids used for clinical diagnostics. Cells and proteins in the blood can provide a rich source of information for the evaluation of human health. Efficient separation of blood components is a necessary process in order to minimize the interference of unwanted components during sensing, separation, and detection.

View Article and Find Full Text PDF

Recent research has demonstrated that temperature and precipitation conditions correlate with successful reproduction in some insectivorous bat species that live in arid and semiarid regions, and that hot and dry conditions correlate with reduced lactation and reproductive output by females of some species. However, the potential long-term impacts of climate-induced reproductive declines on bat populations in western North America are not well understood. We combined results from long-term field monitoring and experiments in our study area with information on vital rates to develop stochastic age-structured population dynamics models and analyzed how simulated fringed myotis (Myotis thysanodes) populations changed under projected future climate conditions in our study area near Boulder, Colorado (Boulder Models) and throughout western North America (General Models).

View Article and Find Full Text PDF

The ability to separate analytes with increasingly similar properties drives the field of separation science. One way to achieve such separations is using trapping and streaming dielectrophoresis (DEP), which directly exploits the subtle differences in the electrophysical properties of analytes. The non-uniform fields necessary for DEP can be formed using various insulator shapes in microchannels.

View Article and Find Full Text PDF

Biotechnology, separation science, and clinical research are impacted by microfluidic devices. Separation and manipulation of bioparticles such as DNA, protein and viruses are performed on these platforms. Microfluidic systems provide many attractive features, including small sample size, rapid detection, high sensitivity and short processing time.

View Article and Find Full Text PDF