Publications by authors named "Marisol S Castaneto"

Human red blood cell acetylcholinesterase (RBC-AChE) activity is valuable for detecting potential exposure to cholinesterase inhibiting substances (CIS). A reliable population-based RBC-AChE activity reference range is critical for early and massive clinical and occupational toxicology screening. Previous published studies were often limited to small numbers of subjects, various testing methods, and crude statistical data analyses.

View Article and Find Full Text PDF

The DoD Cholinesterase Monitoring Program and Cholinesterase Reference Laboratory have safeguarded U.S. government employees in chemical defense for over five decades.

View Article and Find Full Text PDF

Popularity of cannabis-infused products has bloomed since legalization for recreational use of marijuana started. Consumption of cannabis edibles has steadily increased, as restrictions on recreational cannabis smoking have become tighter. This phenomenon enhanced the possibility of these products crossing the state line.

View Article and Find Full Text PDF

Background: A high-throughput and highly efficient analytical platform for urine drug screening is critical in both clinical and forensic settings. Mass spectrometry (MS) has better sensitivity and specificity than conventional immunoassays (IA); however, not all laboratories have the necessary resources and workforce to operate MS. The goal of this study was to evaluate a multidrug biochip with 20 discrete testing regions (DTRs) for high-throughput urine drug screening (UDS).

View Article and Find Full Text PDF

Rationale: Indazole carboxamide synthetic cannabinoids, a prevalent class of recreational drugs, are a major clinical, forensic and public health challenge. One such compound, 5F-ADB, has been implicated in fatalities worldwide. Understanding its metabolism and distribution facilitates the development of laboratory assays to substantiate its consumption.

View Article and Find Full Text PDF

FUB-AMB, an indazole carboxamide synthetic cannabinoid recreational drug, was one of the compounds most frequently reported to governmental agencies worldwide between 2016 and 2019. It has been implicated in intoxications and fatalities, posing a risk to public health. In the current study, FUB-AMB was incubated with human liver microsomes (HLM) to assess its metabolic fate and stability and to determine if its major ester hydrolysis metabolite (M1) was present in 12 authentic forensic human blood samples from driving under the influence of drug cases and postmortem investigations using UHPLC-MS/MS.

View Article and Find Full Text PDF

Synthetic urine (SU), which was primarily utilized by drug testing laboratories as a matrix for quality control preparations, is now commercially sold and can be used to "fool" a positive drug test. To determine if SU can pass as authentic urine, we challenged Army urine drug testing specimen accessioning and testing procedures using eight different commercial SU products. Adulteration (Sciteck AdultaCheck 6) and Onsite SU (Synthetic UrineCheck™) test strips were also evaluated.

View Article and Find Full Text PDF
Article Synopsis
  • * A sensitive method for measuring mescaline in urine involved advanced techniques like gas chromatography-mass spectrometry (GC/MS) and was rigorously validated, showing high accuracy and efficiency in detecting the drug.
  • * Findings revealed no confirmed mescaline use in military personnel during the study, suggesting it doesn't warrant routine screening, though there may be issues with the drug's stability affecting detection rates.
View Article and Find Full Text PDF

Designer piperazines are emerging novel psychoactive substances (NPS) with few high-throughput screening methods for their identification. We evaluated a biochip array technology (BAT) immunoassay for phenylpiperazines (PNP) and benzylpiperazines (BZP) and analyzed 20,017 randomly collected urine workplace specimens. Immunoassay performance at recommended cutoffs was evaluated for PNPI (5 μg/L), PNPII (7.

View Article and Find Full Text PDF

Synthetic cannabinoids (SC), originally developed as research tools, are now highly abused novel psychoactive substances. We present a comprehensive systematic review covering in vivo and in vitro animal and human pharmacokinetics and analytical methods for identifying SC and their metabolites in biological matrices. Of two main phases of SC research, the first investigated therapeutic applications, and the second abuse-related issues.

View Article and Find Full Text PDF

Whereas non-fluoropentylindole/indazole synthetic cannabinoids appear to be metabolized preferably at the pentyl chain though without clear preference for one specific position, their 5-fluoro analogs' major metabolites usually are 5-hydroxypentyl and pentanoic acid metabolites. We determined metabolic stability and metabolites of N-(1-amino-3-methyl-1-oxobutan-2-yl)-1-pentyl-1H-indazole-3-carboxamide (AB-PINACA) and 5-fluoro-AB-PINACA (5F-AB-PINACA), two new synthetic cannabinoids, and investigated if results were similar. In silico prediction was performed with MetaSite (Molecular Discovery).

View Article and Find Full Text PDF

Background: Synthetic cannabinoids (SC) are widely-abused cannabimimetic drugs that do not screen positive in traditional cannabinoids immunoassays, making detection difficult.

Methods And Results: The first commercially-available immunoassay for urinary SC was validated. Limits of detection (5-20 µg/L), imprecision (<13.

View Article and Find Full Text PDF

Synthetic cannabinoid intake is an ongoing health issue worldwide, with new compounds continually emerging, making drug testing complex. Parent synthetic cannabinoids are rarely detected in urine, the most common matrix employed in workplace drug testing. Optimal identification of synthetic cannabinoid markers in authentic urine specimens and correlation of metabolite concentrations and toxicities would improve synthetic cannabinoid result interpretation.

View Article and Find Full Text PDF

Background: Synthetic cannabinoids (SC) are a heterogeneous group of compounds developed to probe the endogenous cannabinoid system or as potential therapeutics. Clandestine laboratories subsequently utilized published data to develop SC variations marketed as abusable designer drugs. In the early 2000s, SC became popular as "legal highs" under brand names such as Spice and K2, in part due to their ability to escape detection by standard cannabinoid screening tests.

View Article and Find Full Text PDF

Synthetic cannabinoids are marketed as legal alternatives to cannabis, as routine urine cannabinoid immunoassays do not detect synthetic cannabinoids. Laboratories are challenged to identify these new designer drugs that are widely available and represent a major public health and safety problem. Immunoassay testing offers rapid separation of presumptive positive and negative specimens, prior to more costly and time-consuming chromatographic confirmation.

View Article and Find Full Text PDF

Deterrence of synthetic cathinone abuse is hampered by the lack of a high-throughput immunoassay screen. The Randox Drugs of Abuse V (DOA-V) Biochip Array Technology contains two synthetic cathinone antibodies: Bath Salt I (BSI) targets mephedrone/methcathinone and Bath Salt II (BSII) targets 3',4'-methylenedioxypyrovalerone (MDPV)/3',4'-methylenedioxy-α-pyrrolidinobutiophenone (MDPBP). We evaluated DOA-V synthetic cathinones performance and conducted a full validation on the original assay with calibrators reconstituted in water, and the new assay with calibrators prepared in lyophilized urine; both utilized the same antibodies and were run on the fully automated Evidence® Analyzer.

View Article and Find Full Text PDF

Objective: Methamphetamine (MAMP) use, distribution, and manufacture remain a serious public health and safety problem in the United States, and children environmentally exposed to MAMP face a myriad of developmental, social, and health risks, including severe abuse and neglect necessitating child protection involvement. It is recommended that drug-endangered children receive medical evaluation and care with documentation of overall physical and mental conditions and have urine drug testing. The primary aim of this study was to determine the best biological matrix to detect MAMP, amphetamine (AMP), methylenedioxymethamphetamine (MDMA), methylenedioxyamphetamine (MDA), and 3,4-methylenedioxyethylamphetamine (MDEA) in environmentally exposed children.

View Article and Find Full Text PDF