Introduction/aims: Ultra high-frequency ultrasound (UHFUS) has been demonstrated to allow easy visualization and quantification of median and digital nerve fascicles; however, there is a lack of normative data for other upper limb nerves. The purpose of this study was to use UHFUS to establish normative reference values and ranges for fascicle count and density within selected upper extremity nerves.
Methods: Twenty-one healthy volunteers underwent sonographic examination of the ulnar, superficial branch of the radial, and radial nerves on one upper limb using UHFUS with a 48 MHz linear transducer.
Introduction/aims: While ultrasound assessment of cross-sectional area and echogenicity has gained popularity as a biomarker for various neuropathies, there is a scarcity of data regarding fascicle count and density in neuropathies or even healthy controls. The aim of this study was to determine whether fascicles within select lower limb nerves (common fibular, superficial fibular, and sural nerves) can be counted in healthy individuals using ultrahigh-frequency ultrasound (UHFUS).
Methods: Twenty healthy volunteers underwent sonographic examination of the common fibular, superficial fibular, and sural nerves on each lower limb using UHFUS with a 48 MHz linear transducer.