The 9th GCCClosed Forum was held just prior to the 2015 Workshop on Recent Issues in Bioanalysis (WRIB) in Miami, FL, USA on 13 April 2015. In attendance were 58 senior-level participants, from eight countries, representing 38 CRO companies offering bioanalytical services. The objective of this meeting was for CRO bioanalytical representatives to meet and discuss scientific and regulatory issues specific to bioanalysis.
View Article and Find Full Text PDFThe topic of incurred sample stability (ISS) has generated considerable discussion within the bioanalytical community in recent years. The subject was an integral part of the seventh annual Workshop on Recent Issues in Bioanalysis (WRIB) held in Long Beach, CA, USA, in April 2013, and at the Global CRO Council for Bioanalysis (GCC) meeting preceding it. Discussion at both events focused on the use of incurred samples for ISS purposes in light of results from a recent GCC survey completed by member companies.
View Article and Find Full Text PDFThe 2013 7th Workshop on Recent Issues in Bioanalysis was held in Long Beach, California, USA, where close to 500 professionals from pharmaceutical and biopharmaceutical companies, CROs and regulatory agencies convened to discuss current topics of interest in bioanalysis. These 'hot' topics, which covered both small and large molecules, were the starting point for fruitful exchanges of knowledge, and sharing of ideas among speakers, panelists and attendees. The discussions led to specific recommendations pertinent to bioanalytical science.
View Article and Find Full Text PDFOver 400 professionals representing pharmaceutical companies, CROs, and multiple regulatory agencies participated in the 6th Workshop on Recent Issues in Bioanalysis (WRIB). Like the previous sessions, this event was in the format of a practical, focused, highly interactive and informative workshop aiming for high-quality, improved regulatory compliance and scientific excellence. Numerous 'hot' topics in bioanalysis of both small and large molecules were shared and discussed, leading to consensus and recommendations among panelists and attendees representing the bioanalytical community.
View Article and Find Full Text PDFDuring the last century, particularly the latter half, spectacular progress has been made in improving the health and longevity of people. The reasons are many, but the development of medicines has played a critical role. This report documents and reflects on the impressive contribution that those working in the pharmaceutical sciences have made to healthcare over the past 50 years.
View Article and Find Full Text PDFThe 5th Workshop on Recent Issues in Bioanalysis (WRIB) was organized by the Calibration and Validation Group as a 2-day full immersion workshop for pharmaceutical companies, CROs and regulatory agencies to discuss, review, share perspectives, provide potential solutions and agree upon a consistent approach to recent issues in the bioanalysis of both small and large molecules. High quality, better compliance to regulations and scientific excellence are the foundation of this workshop. As in the previous editions of this significant event, recommendations were made and a consensus was reached among panelists and attendees, including industry leaders and regulatory experts representing the global bioanalytical community, on many 'hot' topics in bioanalysis.
View Article and Find Full Text PDF"The Global CRO Council (GCC) for Bioanalysis was formed in an effort to bring together many CRO leaders to openly discuss bioanalysis and the regulatory challenges unique to the outsourcing industry"
View Article and Find Full Text PDFThe reanalysis of incurred bioanalytical samples (incurred sample reanalysis) provides additional data that help us to ensure that a 'validated bioanalytical method' is reproducible. While the guidelines for the conduct of incurred sample reanalysis evaluations have been well described, published information pertaining to the occurrence of failures and the manner in which they are resolved has not received the same amount of attention. The purpose of this manuscript is to describe two case studies where incurred sample reanalysis failures were encountered for small molecules, the approaches that were taken to elucidate the root cause of the failures, and the remedial actions that were implemented to prevent such failures from recurring.
View Article and Find Full Text PDFBackground: Modified-release (MR) products are complex dosage forms designed to release drug in a controlled manner to achieve the desired efficacy and safety profiles. Inappropriate control of drug release from such products may result in reduced efficacy or increased toxicity.
Objective: This paper is a summary report of the American Association of Pharmaceutical Scientists, International Pharmaceutical Federation, and Product Quality Research Institute workshop titled "Challenges and Opportunities in Establishing Scientific and Regulatory Standards for Assuring Therapeutic Equivalence of Modified Release Products", held October 1-2, 2009, in Baltimore, Maryland.
The 4th Calibration and Validation Group Workshop on Recent Issues in Regulated Bioanalysis, a 2-day full immersion workshop, was organized by the Calibration and Validation Group. Contract research organizations, pharmaceutical companies and regulatory agencies came together to discuss several 'hot' topics concerning bioanalytical issues and regulatory challenges and to reach a consensus among panelists and attendees on many points regarding method validation of small and large molecules.
View Article and Find Full Text PDFThe 3rd Calibration and Validation Group Workshop on Recent Issues in Regulated Bioanalysis was organized by the Calibration and Validation Group as a 1.5-day full immersion workshop for contract research organizations, pharmaceutical companies and regulatory agencies to discuss several 'hot' topics concerning bioanalytical issues and regulatory challenges. A consensus was reached among panelists and attendees on many points regarding method validation of small molecules.
View Article and Find Full Text PDFModified release products are complex dosage forms designed to release drug in a controlled manner to achieve desired efficacy and safety. Inappropriate control of drug release from such products may result in reduced efficacy or increased toxicity. This workshop provided an opportunity for pharmaceutical scientists from academia, industry, and regulatory agencies to discuss current industry practices and regulatory expectations for demonstrating pharmaceutical equivalence and bioequivalence of MR products, further facilitating the establishment of regulatory standards for ensuring therapeutic equivalence of these products.
View Article and Find Full Text PDFModified-release products are complex dosage forms designed to release drug in a controlled manner to achieve desired efficacy and safety. Inappropriate control of drug release from such products may result in reduced efficacy or increased toxicity. This workshop provided an opportunity for pharmaceutical scientists from academia, industry and regulatory agencies to discuss current regulatory expectations and industry practices for demonstrating pharmaceutical equivalence and bioequivalence of MR products, further facilitating the establishment of regulatory standards for ensuring therapeutic equivalence of these products.
View Article and Find Full Text PDFThis event was organized by the Calibration and Validation Group (a scientific nonprofit organization based in Toronto, Canada) as a 1.5-day workshop for contract research organizations and pharmaceutical companies involved in providing bioanalytical data for bioavailability, bioequivalence, pharmacokinetic and comparability studies.
View Article and Find Full Text PDFBioanalytical methods used to support the drug development process are validated to ensure that they function in the manner in which they are intended. "Incurred" or study samples can vary in their composition when compared with the standards and quality control samples used to validate the method and analyze these samples. During the 3rd American Association of Pharmaceutical Scientists(AAPS)/Food and Drug Administration(FDA) Bioanalytical Workshop, it was suggested that the reproducibility in the analysis of incurred samples be evaluated in addition to the usual prestudy validation activities performed.
View Article and Find Full Text PDFAims: A non-invasive proposed method for measuring CYP3A activity is the urinary 6beta-hydroxycortisol:cortisol ratio. This ratio has been used as an indicator of CYP3A induction and inhibition, with mixed results. This investigation evaluated the relationship between a validated, biomarker, intravenous midazolam clearance and the urinary cortisol ratio under constitutive conditions and with the influence of a moderate CYP3A inhibitor.
View Article and Find Full Text PDFProgesterone products are available in prescription form as well as over-the-counter (OTC) topical preparations sold for "cosmetic" uses. In a randomized study design, the authors compared the drug exposure from an OTC progesterone cream to a Food and Drug Administration-approved oral preparation at the labeled daily doses recommended for each product. Twelve healthy postmenopausal women received 200-mg oral progesterone capsules once daily for 12 days or progesterone cream 40 mg twice daily for 12 days.
View Article and Find Full Text PDFObjectives: Intravenous midazolam is used as an in vivo biomarker of hepatic cytochrome P450 (CYP) 3A activity. Midazolam is a central nervous system depressant and can produce cognitive impairment. The purpose of this study was 2-fold: (1) to determine whether administration of intravenous flumazenil given before intravenous midazolam minimizes cognitive impairment and (2) to determine whether flumazenil pretreatment has an effect on midazolam pharmacokinetics during hepatic CYP3A phenotyping.
View Article and Find Full Text PDFThe 30-minute ratio of 1'-hydroxymidazolam:midazolam plasma concentrations has been used as a measure of midazolam clearance in liver transplant patients. This study determined if a single concentration of 1'-hydroxymidazolam or the ratio of 1'-hydroxymidazolam:midazolam could be used to predict midazolam clearance in healthy subjects. Plasma midazolam and 1'-hydroxymidazolam concentrations from three previous studies were used for analyses.
View Article and Find Full Text PDFMidazolam clearance is used to phenotype hepatic CYP3A activity but requires multiple plasma samples following a single intravenous dose. The authors evaluated the use of a limited sampling scheme, using different assay techniques to determine the reproducibility of such a strategy in estimating midazolam AUC. Seventy-three healthy adults received midazolam as a single intravenous bolus dose.
View Article and Find Full Text PDF