In this work we have investigated the mechanism of nanoparticle synthesis in a low pressure, premixed, laminar flat flame of CH4-O2, doped with iron pentacarbonyl using a combined quartz-crystal-microbalance-particle-mass-spectrometry apparatus. We have unambiguously demonstrated that the formation of nanoparticles in iron pentacarbonyl-doped flames occurs very early, in close proximity to the burner surface, prior to the flame front. This early rise of nanoparticle mass concentration is followed by a sharp drop in nanoparticle concentration at the high temperature flame front.

View Article and Find Full Text PDF

Open Probe is based on a vaporization oven mounted on a transfer line of a gas chromatograph mass spectrometer (GC/MS) which is connected to the MS ion source via a short flow restriction capillary. The probe oven is open to room air while having helium purge flow protection to eliminate or significantly reduce air leakage into the oven and MS ion source. Sample analysis can be as simple as touch (the sample), push (the sample holder) into the open probe oven, and have the results.

View Article and Find Full Text PDF

Pulsed flow modulation (PFM) two-dimensional comprehensive gas chromatography (GC x GC) was combined with quadrupole-based mass spectrometry (MS) via a supersonic molecular beam (SMB) interface using a triple-quadrupole system as the base platform, which enabled tandem mass spectrometry (MS-MS). PFM is a simple GC x GC modulator that does not consume cryogenic gases while providing tunable second GC x GC column injection time for enabling the use of quadrupole-based mass spectrometry regardless its limited scanning speed. The 20-ml/min second column flow rate involved with PFM is handled, splitless, by the SMB interface without affecting the sensitivity.

View Article and Find Full Text PDF

Gas chromatography-mass spectrometry (GC-MS) with supersonic molecular beams (SMBs) (also named Supersonic GC-MS) is based on GC and MS interface with SMBs and on the electron ionization (EI) of vibrationally cold analytes in the SMBs (cold EI) in a fly-through ion source. This ion source is inherently inert and further characterized by fast response and vacuum background filtration capability. The same ion source offers three modes of ionization including cold EI, classical EI and cluster chemical ionization (CI).

View Article and Find Full Text PDF

Pulsed flow modulation (PFM) is based on higher flow rate time compression of the first GC column effluent, which prior to the injection into the second column is stored for a few seconds in a standard fused silica wide bore transfer line. We constructed the PFM device with two standard 1/16 in. brass compression fittings with the insertion of the two columns inside the wide bore 0.