IEEE Trans Ultrason Ferroelectr Freq Control
November 2024
Objective: The consequences associated with blood clots are numerous and are responsible for many deaths worldwide. The assessment of treatment efficacy is necessary for patient follow-up and to detect treatment-resistant patients. The aim of this study was to characterize the effect of treatment on blood clots in vitro using quantitative ultrasound parameters.
View Article and Find Full Text PDFObjective: Improve the characterization of mechanical properties of blood clots. Parameters derived from shear wave (SW) velocity and SW amplitude spectra were determined for gel phantoms and in vitro blood clots.
Methods: Homogeneous phantoms and phantoms with gel or blood clot inclusions of different diameters and mechanical properties were analyzed.
IEEE Trans Ultrason Ferroelectr Freq Control
December 2022
Objective myocardial contractility assessment during stress tests aims to improve the diagnosis of myocardial ischemia. Tissue Doppler imaging (TDI) or optical flow (OF) speckle tracking echocardiography (STE) has been used to quantify myocardial contractility at rest. However, this is more challenging during stress tests due to image decorrelation at high heart rates.
View Article and Find Full Text PDFChildhood obesity is linked to higher adult mortality and morbidity from atherosclerosis. It is primordial to detect at-risk children earlier-on to prevent disease progression. Carotid intima-media thickness (IMT) is a subclinical radiological marker for early atherosclerosis.
View Article and Find Full Text PDFBackground: Mechanical ventilation is a common therapy in operating rooms and intensive care units. When ill-adapted, it can lead to ventilator-induced lung injury (VILI), which is associated with poor outcomes. Excessive regional pulmonary strain is thought to be a major mechanism responsible for VILI.
View Article and Find Full Text PDFBackground: There is a need for a specific atherosclerotic risk assessment for people living with HIV (PLWH).
Setting: A machine learning classification model was applied to PLWH and control subjects with low-to-intermediate cardiovascular risks to identify associative predictors of diagnosed carotid artery plaques. Associations with plaques were made using strain elastography in normal sections of the common carotid artery and traditional cardiovascular risk factors.
J Vasc Interv Radiol
May 2022
Purpose: To compare the mechanical properties of aneurysm content after endoleak embolization with a chitosan hydrogel (CH) with that with a chitosan hydrogel with sodium tetradecyl sulfate (CH-STS) using strain ultrasound elastography (SUE).
Materials And Methods: Bilateral common iliac artery type Ia endoleaks were created in 9 dogs. Per animal, 1 endoleak was randomized to blinded embolization with CH, and the other, with CH-STS.
Objective: To develop a quantitative ultrasound (QUS)- and elastography-based model to improve classification of steatosis grade, inflammation grade, and fibrosis stage in patients with chronic liver disease in comparison with shear wave elastography alone, using histopathology as the reference standard.
Methods: This ancillary study to a prospective institutional review-board approved study included 82 patients with non-alcoholic fatty liver disease, chronic hepatitis B or C virus, or autoimmune hepatitis. Elastography measurements, homodyned K-distribution parametric maps, and total attenuation coefficient slope were recorded.
Objective: To study the impact of varying the external compression exerted by the ultrasound probe when performing a carotid strain elastography exam.
Methods: Nine healthy volunteers (mean age 43 years ±13 years; 6 men) underwent a vascular ultrasound elastography exam using a custom made sound feedback handle embedding the probe, and allowing the sonographer to adjust the applied compression. A clinical standard practice (SP) force was first recorded, and then predetermined compression (PDC) forces were applied, ranging from 0 to 5 N for the left common carotid artery (CCA) or 2-12 N for the left internal carotid artery (ICA).
Ultrasound vascular strain imaging has shown its potential to interrogate the motion of the vessel wall induced by the cardiac pulsation for predicting plaque instability. In this study, a sparse model strain estimator (SMSE) is proposed to reconstruct a dense strain field at a high resolution, with no spatial derivatives, and a high computation efficiency. This sparse model utilizes the highly-compacted property of discrete cosine transform (DCT) coefficients, thereby allowing to parameterize displacement and strain fields with truncated DCT coefficients.
View Article and Find Full Text PDFShear wave elastography (speed and dispersion), local attenuation coefficient slope and homodyned-K parametric imaging were used for liver steatosis grading. These ultrasound biomarkers rely on physical interactions between shear and compression waves with tissues at both macroscopic and microscopic scales. These techniques were applied in a context not yet studied with ultrasound imaging, that is, monitoring steatosis of force-fed duck livers from pre-force-fed to foie gras stages.
View Article and Find Full Text PDFObjectives: Assess carotid artery strain and motion in people living with HIV as markers of premature aging using ultrasound noninvasive vascular elastography (NIVE).
Methods: Seventy-four HIV-infected and 75 age-matched control subjects were recruited from a prospective, controlled cohort study from October 2015 to October 2017 (mean age 56 years ± 8 years; 128 men). NIVE applied to longitudinal ultrasound images of common and internal carotid arteries quantified the cumulated axial strain, cumulated shear strain, cumulated axial translation, and cumulated lateral translations.
As the complexity of ultrasound signal processing algorithms increases, it becomes more difficult to demonstrate their added value and thus robust validation strategies are required. We propose a method of manufacturing ultrasonic vascular phantoms mimicking an atheromatous plaque in an internal carotid artery bifurcation for applications in flow imaging and elastography. During the fabrication process, a soft inclusion mimicking a stenotic lipid pool was embedded within the vascular wall.
View Article and Find Full Text PDFObjectives: Evaluate non-invasive vascular elastography (NIVE) in detecting vascular changes associated with obese children.
Methods: Case-control study to evaluate NIVE in 120 children, 60 with elevated body mass index (BMI) (≥ 85th percentile for age and sex). Participants were randomly selected from a longitudinal cohort, evaluating consequences of obesity in healthy children with one obese parent.
Objective: The purpose of this study was to evaluate ultrasound elastography and echogenicity analysis to discriminate between carotid plaques in patients with symptomatic internal carotid artery (ICA) stenosis versus patients with asymptomatic stenosis.
Subjects And Methods: Patients with symptomatic and asymptomatic ICA stenosis of more than 50% were recruited for the study. After both carotid arteries were scanned, plaque translation and elastography and echogenicity features were assessed.
Polar strain (radial and circumferential) estimations can suffer from artifacts because the center of a nonsymmetrical carotid atherosclerotic artery, defining the coordinate system in cross-sectional view, can be misregistered. Principal strains are able to remove coordinate dependency to visualize vascular strain components (i.e.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
March 2019
Quantitative ultrasound (QUS) imaging methods, including elastography, echogenicity analysis, and speckle statistical modeling, are available from a single ultrasound (US) radio-frequency data acquisition. Since these US imaging methods provide complementary quantitative tissue information, characterization of carotid artery plaques may gain from their combination. Sixty-six patients with symptomatic ( n = 26 ) and asymptomatic ( n = 40 ) carotid atherosclerotic plaques were included in the study.
View Article and Find Full Text PDFThe original version of this article contained a mistake in Fig. 1: The old version was used during figure processing instead of the replacement. The correct figure is shown below.
View Article and Find Full Text PDFBackground: Common carotid artery intima-media thickness is a marker of subclinical atherosclerosis. In children, increased intima-media thickness is associated with obesity and the risk of cardiovascular events in adulthood.
Objective: To compare intima-media thickness measurements using B-mode ultrasound, radiofrequency (RF) echo tracking, and RF speckle probability distribution in children with normal and increased body mass index (BMI).
Objective: Vulnerable and nonvulnerable carotid artery plaques have different tissue morphology and composition that may affect plaque biomechanics. The objective of this study is to evaluate plaque vulnerability with the use of ultrasound noninvasive vascular elastography (NIVE).
Materials And Methods: Thirty-one patients (mean [± SD] age, 69 ± 7 years) with stenosis of the internal carotid artery of 50% or greater were enrolled in this cross-sectional study.
The objectives were to compare the performance of a segmentation algorithm, based on the minimization of an uncertainty function, to delineate contours of external elastic membrane and lumen of human coronary arteries imaged with 40 and 60 MHz IVUS, and to use values of this function to delineate portions of contours with highest uncertainty. For 8 patients, 40 and 60 MHz IVUS coronary data acquired pre- and post-interventions were used, for a total of 68,516 images. Manual segmentations of contours (on 2312 images) performed by experts at three core laboratories were the gold-standards.
View Article and Find Full Text PDFPurpose: To assess the ability of noninvasive vascular elastography (NIVE) to help characterize endoleaks and thrombus organization in a canine model of abdominal aortic aneurysm after endovascular aneurysm repair with stent-grafts, in comparison with computed tomography (CT) and pathologic examination findings.
Materials And Methods: All protocols were approved by the Animal Care Committee in accordance with the guidelines of the Canadian Council of Animal Care. Stent-grafts were implanted in a group of 18 dogs with aneurysms created in the abdominal aorta.