The ICH M10 guideline establishes global standards for bioanalytical method validation for pharmacokinetic assays, focusing on data reliability and accuracy across studies. A significant component is cross-validation, which should be performed to ensure data comparability when multiple methods or laboratories are involved in a single study or across studies where comparison will be performed. However, ICH M10 does not specify acceptance criteria for cross-validation, creating challenges for the industry because traditionally many laboratories have always utilized acceptance criteria to "pass" or "fail" the study.
View Article and Find Full Text PDFSince 2011, the European Bioanalysis Forum has been discussing the topic of context-of-use for biomarker assays, in support of a cross-industry implementation of its principles. The discussions have led to the acknowledgement of the challenges that we face as an industry in implementing these principles. In addition to scientific recommendations, the European Bioanalysis Forum has addressed these challenges by providing recommendations on organizational design, and what works in both sponsor and contract research organizations, to support and enable context-of-use across biomarker strategies.
View Article and Find Full Text PDFCritical reagents play a crucial role in ligand-binding assays; the robustness and reliability of an assay is defined by the quality and long-term availability of these reagents. However, neither regulatory guidelines nor relevant scientific papers provide clear directions for set-up, life cycle management and, more importantly, the acceptance criteria required for the testing of the critical reagents for pharmacokinetic, biomarker and immunogenicity assays. The ambiguity from current guidelines can be a challenge for the bioanalytical community.
View Article and Find Full Text PDFEuropean Bioanalysis Forum Workshop, Lisbon, Portugal, September 2016: At the recent European Bioanalysis Forum Focus Workshop, 'current analysis of immunogenicity: best practices and regulatory hurdles', several important challenges facing the bioanalytical community in relation to immunogenicity assays were discussed through a mixture of presentations and panel sessions. The main areas of focus were the evolving regulatory landscape, challenges of assay interferences from either drug or target, cut-point setting and whether alternative assays can be used to replace neutralizing antibody assays. This workshop report captures discussions and potential solutions and/or recommendations made by the speakers and delegates.
View Article and Find Full Text PDFComplement activation correlates to rheumatoid arthritis disease activity, and increased amounts of the complement split product C5a is observed in synovial fluids from rheumatoid arthritis patients. Blockade of C5a or its receptor (C5aR) is efficacious in several arthritis models. The aim of this study was to investigate the role of C5a and C5aR in human rheumatoid arthritis and psoriatic arthritis-both with respect to expression and function.
View Article and Find Full Text PDFBioanalysis
December 2017
The 2017 11th Workshop on Recent Issues in Bioanalysis took place in Los Angeles/Universal City, California, on 3-7 April 2017 with participation of close to 750 professionals from pharmaceutical/biopharmaceutical companies, biotechnology companies, contract research organizations and regulatory agencies worldwide. WRIB was once again a 5-day, week-long event - a full immersion week of bioanalysis, biomarkers and immunogenicity. As usual, it was specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest including both small- and large-molecule analysis involving LC-MS, hybrid ligand-binding assay (LBA)/LC-MS and LBA approaches.
View Article and Find Full Text PDFThe analysis of biomarkers by ligand-binding assays offers significant challenges compared with the bioanalysis of small and large molecule drugs. The presence of endogenous analyte is a commonly cited issue. Also the sourcing and application of appropriate calibration or reference standards can present many issues.
View Article and Find Full Text PDFFlow cytometry is a powerful tool that can be used for the support of (pre)clinical studies. Although various white papers are available that describe the set-up and validation of the instrumentation (the flow cytometer) and validation of flow cytometry methods, to date no guidelines exist that address the requirements for performing flow cytometry in a regulated environment. In this manuscript, the European Bioanalysis Forum presents additional practice guidance on the use of flow cytometry in the support of drug development programs and addresses areas that are not covered in the previous publications.
View Article and Find Full Text PDFEuropean Bioanalysis Forum Focus Workshop, Lisbon, Portugal, 9-10 June 2016 At the recent European Bioanalysis Forum's Focus Workshop 'Bringing Assay Validation and Analysis of Biomarkers into Practice', the discussion on best practice for biomarker assay validation continued. Both the presentations and the adjacent panel discussions yielded valuable food for thought for the broader bioanalytical community. The present conference report summarizes the essence from these discussions and from the proposals or conclusions made by all delegates on how to increase the necessary connectivity of the stakeholders involved in the bioanalysis of biomarkers.
View Article and Find Full Text PDFInterference testing of co-medication in bioanalytical method validation has become an area of debate in view of the increased specificity offered by current state-of-the-art technology in both LC-MS/MS and ligand-binding assay platforms. In view of this, and considering the extensive experience within the European Bioanalysis Forum member companies, we evaluated the impact of co-medication on the performance of hundreds of bioanalytical methods with the aim of providing a science-based recommendation on how to evaluate and document potential interference from co-medication on the PK parameters in clinical studies in patients and volunteers.
View Article and Find Full Text PDFThe 2015 9th Workshop on Recent Issues in Bioanalysis (9th WRIB) took place in Miami, Florida with participation of 600 professionals from pharmaceutical and biopharmaceutical companies, biotechnology companies, contract research organizations and regulatory agencies worldwide. WRIB was once again a 5 day, week-long event - A Full Immersion Bioanalytical Week - specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest in bioanalysis. The topics covered included both small and large molecules, and involved LCMS, hybrid LBA/LCMS and LBA approaches, including the focus on biomarkers and immunogenicity.
View Article and Find Full Text PDFThe principles of tiered approach have been part of the bioanalytical toolbox for some years. Nevertheless, an in spite of many valuable discussions in industry, they remain difficult to apply in a harmonized way for a broad array of studies in early drug development where these alternative approaches to regulated validation would make sense. The European Bioanalysis Forum has identified the need to proposes some practical workflows for five categories of studies for chromatography based assays where scientific validation will allow additional freedom while safeguarding scientific rigor and robust documentation: quantification of metabolites in plasma in relation to ICH M3(R2), urine analysis, tissue homogenate analysis, and preclinical and clinical studies in early stages of drug development.
View Article and Find Full Text PDFIntroduction: NNC0109-0012, a novel human monoclonal antibody that binds to and neutralizes the activity of interleukin-20, was investigated as a potential treatment for inflammatory diseases. Pharmacokinetic (PK) modeling was performed using data from four completed clinical phase 1/2 trials to better understand the clinical PK of NNC0109-0012.
Methods: The populations included were patients with rheumatoid arthritis (RA), chronic plaque psoriasis, and healthy volunteers.
Ligand binding assays (LBAs) have been the method of choice for protein analyte measurements for more than four decades. Over the years, LBA methods have improved in sensitivity and achieved larger dynamic ranges by using alternative detection systems and new technologies. As a consequence, the landscape and application of immunoassay platforms has changed dramatically.
View Article and Find Full Text PDFThe bioanalytical scientist plays a key role in the project team for the drug development of biotherapeutics from the discovery to the marketing phase. Information from the project team members is required for assay development and sample analysis during the discovery, preclinical and clinical phases of the project and input is needed from the bioanalytical scientist to help data interpretation. The European Bioanalysis Forum target team 20 discussed many of the gaps in information and communication between the bioanalytical scientist and project team members as a base for providing a perspective on the bioanalytical scientist's role and interactions within the project team.
View Article and Find Full Text PDFInsulin detemir (detemir) has previously been shown to be associated with lower within-subject variability compared with other basal insulin preparations in adults with type 1 diabetes mellitus (T1DM). This randomized, double-blind, crossover trial compared the within-subject variability of detemir and insulin glargine (glargine) in pharmacokinetic properties in children and adolescents with T1DM. The trial enrolled 32 children and adolescents (19 girls and 13 boys; mean +/- SD: age 13 +/- 2.
View Article and Find Full Text PDFAlterations in specific signal transduction pathways may explain the increased expression of proinflammatory cytokines seen in inflammatory diseases such as psoriasis. We reveal increased TNF-alpha protein expression, but similar TNF-alpha mRNA levels, in lesional compared with nonlesional psoriatic skin, demonstrating for the first time that TNF-alpha expression in lesional psoriatic skin is regulated posttranscriptionally. Increased levels of activated MAPK-activated protein kinase 2 (MK2) together with increased MK2 kinase activity were found in lesional compared with nonlesional psoriatic skin.
View Article and Find Full Text PDFWe wish to report the synthesis and structure-activity relationship (SAR) of a series of 4-aminobenzophenones, as a novel compound class with high antiinflammatory activity. Our initial lead, (4-[(2-aminophenyl)amino]phenyl)(phenyl)methanone (3), was systematically optimized and resulted in compounds that potently inhibited the release of the proinflammatory cytokines IL-1beta and TNF-alpha in human peripheral blood mononuclear cells stimulated by LPS. One of the most potent compounds, among others, was (4-[(2-aminophenyl)amino]-2-chlorophenyl)(2-methylphenyl)methanone (45) with IC(50) values of 14 and 6 nM for the inhibition of IL-1beta and TNF-alpha, respectively.
View Article and Find Full Text PDF