Bull Environ Contam Toxicol
September 2024
In the present paper, the assessment of vortex-assisted dispersive magnetic solid-phase extraction using amino-functionalized mesoporous combined with direct magnetic sorbent sampling (DMSS) in flame or furnace atomic absorption spectrometry (FAAS or FF-AAS) was demonstrated for highly sensitive silver determination in water samples. The developed method showed significant enrichment factors compared to conventional pneumatic nebulization by FAAS, 607 for DMSS-FF-AAS and 114 for DMSS-FAAS. The analytical curve showed linearity in the range from 5.
View Article and Find Full Text PDFAnal Methods
December 2022
A solid phase extraction-based (SPE) procedure for simultaneous preconcentration of five tricyclic antidepressants (TCAs), amitriptyline hydrochloride (AMT), nortriptyline hydrochloride (NOR), doxepin hydrochloride (DOX), imipramine hydrochloride (IMI), and clomipramine hydrochloride (CLO) from water samples with determination by HPLC-DAD is proposed. Polymers were characterized by FT-IR, SEM, and thermogravimetric analysis. SPE-based methods were carried out by the preconcentration of 320.
View Article and Find Full Text PDFFood Chem
January 2021
The development of a novel molecularly imprinted solid-phase extraction (MISPE) method for simultaneous preconcentration of imazapyr (IMP), imazapic (IMZ) and imazethapyr (IMT) with determination by HPLC-PAD (High performance liquid chromatography - photodiode-array detector) is proposed. The polymer synthesis was performed using imazethapyr as template molecule and 1-vinylimidazole as functional monomer. The method is based on preconcentration of 100.
View Article and Find Full Text PDFFood Chem
October 2019
In the present paper, a new analytical preconcentration/speciation method for antimony species determination in bottled mineral water samples using the SiO/AlO/SnO adsorbent was developed. The method is based on selective adsorption of Sb(III) ions by SiO/AlO/SnO under a wide pH range (2.5-7.
View Article and Find Full Text PDFMater Sci Eng C Mater Biol Appl
February 2016
In the present study a hybrid molecularly imprinted poly(methacrylic acid-trimethylolpropane trimethacrylate)-silica (MIP) was synthesized and modified with (3-glycidyloxypropyl)trimethoxysilane (GPTMS) with posterior opening of epoxy ring to provide hydrophilic properties of material in the extraction of folic acid from aqueous medium. The chemical and structural aggregates of hybrid material were characterized by means of Fourier Transform Infrared (FT-IR), Transmission Electron Microscopy (TEM), Scanning Electron Microscopy (SEM), Thermogravimetric analysis (TGA) and textural data. Selectivity data of MIP were compared to non-imprinted polymer (NIP) through competitive sorption studies in the presence of caffeine, paracetamol or 4-aminobenzamide yielding relative selectivity coefficients (k′) higher than one unit, thus confirming the selective character of MIP even in the presence of structurally smaller compounds than the folic acid.
View Article and Find Full Text PDFBull Environ Contam Toxicol
August 2015
A facile and reliable UV-Vis spectrophotometric method associated with vortex-assisted dispersive liquid-liquid microextraction has been developed and applied to the determination of U(VI) at low levels in water samples. It was based on preconcentration of 24.0 mL sample at pH 8.
View Article and Find Full Text PDFA new ion-selective cross-linked poly(vinylimidazole-co-ethylene glycol dimethacrylate) prepared via a double-imprinting process was developed for the recognition and preconcentration of Pb(2+) from water samples. The sorbent was characterized by FT-IR, SEM, TGA and textural data. The maximum dynamic sorption capacity of Pb(2+) was 42.
View Article and Find Full Text PDFJ AOAC Int
June 2014
The main purpose of this research was to synthesize crosslinked poly(4-vinylpyridine-ethylene glycol dimethacrylate) and evaluate its feasibility for highly sensitive and selective determination of Cd in water samples by using flow injection flame atomic absorption spectrometry. The crosslinked polymer, prepared by bulk polymerization, was characterized by FTIR spectrometry and scanning electron microscopy. The flow injection solid-phase method was based on preconcentration of 20.
View Article and Find Full Text PDFIn the present study, the performance of multi-walled carbon nanotubes (MWCNTs) grafted with 3-mercaptopropyltrimethoxysilane (3-MPTMS), used as a solid phase extractor for Cd(2+) preconcentration in a flow injection system coupled to flame atomic absorption spectrometry (FAAS), was evaluated. The procedure involved the preconcentration of 20.0 mL of Cd(2+) solution at pH 7.
View Article and Find Full Text PDFTalanta
October 2011
The present paper describes the synthesis of a new chemically modified cellulose microfiber through oxidation with sodium periodate and functionalization with N,N'-bis (2-aminoethyl)-1,2-ethanediamine for the fast and selective preconcentration of Cd(II) ions in flow system analysis. The new sorbent was characterized by FTIR, SEM, and surface area values. The uptake behavior of Cd(II) ions onto this sorbent was evaluated from kinetic data, pseudo-first-order and pseudo-second-order models, as well as from Langmuir, Freundlich and Langmuir-Freundlich adsorption isotherms.
View Article and Find Full Text PDFAnal Chim Acta
October 2011
A novel ion imprinted polyvinylimidazole-silica hybrid copolymer (IIHC) was synthesized and used as a selective solid sorbent for Pb(2+) ions preconcentration using an on-line solid phase extraction (SPE) system coupled to TS-FF-AAS. The ionic hybrid sorbent was prepared using 1-vinylimidazole and 3-(trimethoxysilyl)propylmethacrylate as monomers, Pb(2+) ions as template, tetraethoxysilane as reticulating agent and 2,2'-azobis-isobutyronitrile as initiator. The best on-line SPE conditions concerning sorption behavior, including sample pH (6.
View Article and Find Full Text PDFIn this study, a sorbent flow preconcentration system coupled to amperometric detector for the chloroguaiacol (4-chloro-2-methoxyphenol) determination at submicromolar levels is described. The satisfactory selectivity of the proposed method was attained by means of the use of a chloroguaiacol-imprinted polymer, whose the synthesis was carried out by bulk polymerization. Flow and chemical parameters associated to the preconcentration system, such as sample pH, preconcentration and elution flow rates, concentration of the carrier solution (KCl) and eluent volume were investigated through multivariate analysis.
View Article and Find Full Text PDFThe present paper proposes the application of multiwall carbon nanotubes (MWCNTs) as a solid sorbent for lead preconcentration using a flow system coupled to flame atomic absorption spectrometry. The method comprises the preconcentration of Pb (II) ions at a buffered solution (pH 4.7) onto 30mg of MWCNTs previously oxidized with concentrated HNO(3).
View Article and Find Full Text PDF