Purpose: This study aimed to develop and evaluate a simple, non-destructive method for assessing the misfit and passivity of implant-retained prostheses frameworks.

Materials And Methods: To simulate the rehabilitation of a mandible posterior partially edentulous area using 3-unit screw-retained frameworks supported by two implants were fabricated and divided into the following five groups (n = 10 in each group): OP = one-piece framework cast in Co-Cr with the conventional method (control-group); Co-Cr frameworks sectioned and welded by laser (=LAS) or tungsten inert gas (=TIG); Co-Cr CAD-CAM = milled Co-Cr framework; Zir CAD-CAM = milled zirconia framework. The horizontal |X| and vertical |Y| misfits were measured using confocal laser scanning microscopy with one or both screws tightened.

View Article and Find Full Text PDF

Purpose: This study used digital image correlation (DIC) to evaluate the strain transferred by splinted and non-splinted screw-retained fixed partial dentures (FPDs) supported by short and conventional implants.

Material And Methods: Four polyurethane models were fabricated to simulate half of the mandibular arch with acrylic resin replicas of the first premolar. Short (5 mm) and/or conventional (11 mm) implants replaced the second premolar and the first and second molars.

View Article and Find Full Text PDF

Objective: To evaluate the influence of different veneering materials (porcelain and resin) and implants (short and conventional) in the strain distribution of implant-supported splinted fixed partial dentures (FPDs) using digital image correlation (DIC).

Material And Methods: Four polyurethane models were fabricated with resin replicas (first premolar) and short and/or conventional implants replacing the second premolar and first and second molars, according to the following configurations: G1, 2 conventional (second premolar and first molar) and 1 short (second molar) implant; G2, 1 conventional (second premolar) and 2 short (first and second molar) implants; G3, 3 short implants; G4, 3 conventional implants. Porcelain- and resin-veneered splinted FPDs were screwed to the implant abutments.

View Article and Find Full Text PDF

Aims: This study used finite element analysis to compare the biomechanical performance of splinted (SP) and nonsplinted (NSP) prostheses to regular and short length Morse taper implants in the posterior side of the mandible.

Methods: The authors used 3-dimensional geometric models of regular implants (∅4 × 11 mm) and short implants (∅4 × 5 mm) housed in the corresponding bone edges of the posterior left mandibular hemiarch involving tooth 34. The 8 experimental groups were: the control group SP (3 regular implants rehabilitated with SP), group 1SP (2 regular and 1 short implants rehabilitated with SP), group 2SP (1 regular and 2 short implants rehabilitated with SP), group 3SP (3 short implants rehabilitated with SP), the control group NSP (3 regular implants rehabilitated with NSP), group 1NSP (2 and 1 short implants rehabilitated with NSP), group 2NSP (1 regular and 2 short implants rehabilitated with NSP), and group 3NSP (3 short implants rehabilitated with NSP).

View Article and Find Full Text PDF

This research evaluated the influence of temporary cements (eugenol-containing [EC] or eugenol-free [EF]) on the tensile strength of Ni-Cr copings fixed with self-adhesive resin cement to the metal coronal substrate. Thirty-six temporary crowns were divided into 4 groups (n=9) according to the temporary cements: Provy, Dentsply (eugenol-containing), Temp Cem, Vigodent (eugenol-containing), RelyX Temp NE, 3M ESPE (eugenol-free) and Temp Bond NE, Kerr Corp (eugenol-free). After 24 h of temporary cementation, tensile strength tests were performed in a universal testing machine at a crosshead speed of 0.

View Article and Find Full Text PDF

This study aims to compare stress transmitted to implants and passive fit of one-piece cast frameworks fabricated with 3 different materials: commercially pure titanium (G1-CP Ti), cobalt-chromium alloy (G2-Co-Cr), and nickel-chromium-titanium alloy (G3-Ni-Cr-Ti). In total, 12 frameworks simulating bars for fixed prosthesis in a model with 5 implants were fabricated. The passive fit of the framework interface was measured using an optical microscope and the stresses transmitted to implants were measured using quantitative photoelastic analysis.

View Article and Find Full Text PDF

Objectives: To evaluate the effect of thermal cycling and inner surface treatment with aluminum oxide at different granulations on the tensile strength of Ni-Cr copings cemented with different cementing agents.

Materials And Methods: Ninety-six metal copings were manufactured and divided into two groups: before and after thermal cycling (n = 48). The copings of both groups were internally treated by sandblasting with aluminum oxide particles of 100 (n = 24) and 320 (n = 24) mesh.

View Article and Find Full Text PDF

Casting in the presence of oxygen may result in an improvement of the corrosion performance of most alloys. However, the effect of corrosion on the casting without oxygen for dental materials remains unknown. The aim of this study was to investigate the influence of the casting technique and atmosphere (argon or oxygen) on the corrosion behavior response of six different dental casting alloys.

View Article and Find Full Text PDF

This study aims to investigate a possible correlation between vertical misfits and the stresses transmitted to implants from one-piece casted frameworks fabricated with 3 different materials: commercially pure titanium, cobalt chromium alloy, and nickel chromium titanium alloy. Twelve frameworks simulating screw-retained prosthesis were fabricated from a master cast with 5 implants. Each framework was screwed (20 Ncm) over a metal cast and the vertical mesial and distal misfits were measured using an optical microscope.

View Article and Find Full Text PDF

Statement Of Problem: Whether splinting or not splinting adjacent implants together can optimize the stress/strain transfer to the supporting structures remains controversial.

Purpose: The purpose of this study was to compare the photoelasticity and digital image correlation (DIC) in analyzing the stresses/strains transferred by an implant-supported prosthesis.

Material And Methods: A polymethylmethacrylate model was made with a combination of acrylic resin replicas of a mandibular first premolar and second molar and threaded implants replacing the second premolar and first molar.

View Article and Find Full Text PDF

Purpose: This study compared the loosening torque of experimental conical-head abutment screws to that of conventional flat-head screws of implants with external-hex (EH) and internal tri-channel (IT) connections before and after mechanical loading.

Materials And Methods: Forty-four implant/screw/abutment assemblies were divided into four groups: EH/flat-head screw (EH), IT/flat-head screw (IT), EH/conical-head screw (EHCS), and IT/conical-head screw (ITCS). Three assemblies from each group were analyzed in a stereoscopic magnifier and then returned to their respective groups.

View Article and Find Full Text PDF

Purpose: The present study aimed to evaluate the retention and stress distribution of conventional (C) RPD and compare to RPD associated to implant for support (IS) and retention (IR).

Methods: Frameworks were cast from cp Ti (n=18) and Co-Cr alloy (n=18) by plasma and injected by vacuum-pressure. Conventional RPDs were compared to implant associated RPDs using a distal implant to support (IS) or to support and retain (IR) RPD.

View Article and Find Full Text PDF

This finite element analysis (FEA) compared stress distribution on different bony ridges rehabilitated with different lengths of morse taper implants, varying dimensions of metal-ceramic crowns to maintain the occlusal alignment. Three-dimensional FE models were designed representing a posterior left side segment of the mandible: group control, 3 implants of 11 mm length; group 1, implants of 13 mm, 11 mm and 5 mm length; group 2, 1 implant of 11 mm and 2 implants of 5 mm length; and group 3, 3 implants of 5 mm length. The abutments heights were 3.

View Article and Find Full Text PDF

Purpose: The aim of the present study was to evaluate if a smaller morse taper abutment has a negative effect on the fracture resistance of implant-abutment connections under oblique compressive loads compared to a conventional abutment.

Materials And Methods: Twenty morse taper conventional abutments (4.8 mm diameter) and smaller abutments (3.

View Article and Find Full Text PDF

Purpose: Adequate passive-fitting of one-piece cast 3-element implant-supported frameworks is hard to achieve. This short communication aims to present an alternative method for section of one-piece cast frameworks and for casting implant-supported frameworks.

Materials And Methods: Three-unit implant-supported nickel-chromium (Ni-Cr) frameworks were tested for vertical misfit (n = 6).

View Article and Find Full Text PDF

The aim of this study was to determine the effect of the oral environment on the corrosion of dental alloys with different compositions, using electrochemical methods. The corrosion rates were obtained from the current-potential curves and electrochemical impedance spectroscopy (EIS). The effect of artificial saliva on the corrosion of dental alloys was dependent on alloy composition.

View Article and Find Full Text PDF

Purpose: A digital image correlation (DIC) method for full-field surface strain measurement was used to analyze the effect of two veneering materials for implant supported crowns on the strain distribution within the surrounding bone.

Methods: An epoxy resin model of a bone block was made by housing acrylic resin replicas of a mandibular first premolar and second molar together with threaded implants replacing the second premolar and first molar. Porcelain-veneered (G1 and G3) and resin-veneered (G2 and G4) screw-retained splinted crowns were fabricated and loaded with (G1 and G2) and without (G3 and G4) the presence of the second molar replica.

View Article and Find Full Text PDF

An inappropriate prosthetic fit could cause stress over the interface implant/bone. The objective of this study was to compare stresses transmitted to implants from frameworks cast using different materials and to investigate a possible correlation between vertical misfits and these stresses. Fifteen one-piece cast frameworks simulating bars for fixed prosthesis in a model with five implants were fabricated and arranged into three different groups according to the material used for casting: CP Ti (commercially pure titanium), Co-Cr (cobalt-chromium) or Ni-Cr-Ti (nickel-chromium-titanium) alloys.

View Article and Find Full Text PDF

This study compared splinted and non-splinted implant-supported prosthesis with and without a distal proximal contact using a digital image correlation method. An epoxy resin model was made with acrylic resin replicas of a mandibular first premolar and second molar and with threaded implants replacing the second premolar and first molar. Splinted and non-splinted metal-ceramic screw-retained crowns were fabricated and loaded with and without the presence of the second molar.

View Article and Find Full Text PDF

Purpose: The aim of the present study was to evaluate commercially pure titanium (CP Ti) casting quality when a specific to titanium and a conventional phosphate bonded investments were used under different mold temperatures. For this, the evaluated parameters were surface roughness, bending strength, Vickers microhardness, casting quality by radiographies and microstructure of CP Ti.

Methods: Wax patterns (28 mm × 3 mm × 1 mm) were invested using two phosphate bonded investments: Rematitan Plus (REM), specific to titanium, and Castorit Super C (CAS), a conventional investment, fired and cooled until reaching two mold temperatures: 430 °C (430) and room temperature (RT).

View Article and Find Full Text PDF

This study compared vertical and passive fit of one-piece cast frameworks made with 3 different materials: commercially pure titanium (CP Ti - G1), cobalt-chromium alloy (Co-Cr - G2) and nickel-chromium-titanium alloy (Ni-Cr-Ti - G3). Fifteen frameworks were obtained simulating bars for fixed prosthesis in a model with 5 implants. The passive and vertical fit of the framework interface was measured using an optical microscope at x30 magnification.

View Article and Find Full Text PDF

The restoration of endodontically treated teeth is a topic that is extensively studied and yet remains controversial. This article emphasizes the characteristics of endodontically treated teeth and some principles to be observed when restorations of these teeth are planned. It was concluded that the amount of remaining coronal tooth structure and functional requirements determine the best way to restore these teeth, indicating the material to be used, direct or indirect restorations, associated or not to posts.

View Article and Find Full Text PDF

The aim of this study was to analyze the shear bond strength between commercially pure titanium, with and without laser welding, after airbone-particle abrasion (Al(2)O(3)) and 2 indirect composites. Sixty-four specimens were cast and divided into 2 groups with and without laser welding. Each group was divided in 4 subgroups, related to Al(2)O(3) grain size: A - 250 microm; B - 180 microm; C- 110 microm; and D - 50 microm.

View Article and Find Full Text PDF

Unlabelled: One of the most important properties of artificial teeth is the abrasion wear resistance, which is determinant in the maintenance of the rehabilitation's occlusal pattern.

Objectives: This in vitro study aims to evaluate the abrasion wear resistance of 7 brands of artificial teeth opposed to two types of antagonists.

Material And Methods: Seven groups were prepared with 12 specimens each (BIOLUX & BL, TRILUX & TR, BLUE DENT & BD, BIOCLER & BC, POSTARIS & PO, ORTHOSIT & OR, GNATHOSTAR & GN), opposed to metallic (M & nickel-chromium alloy), and to composite antagonists (C & Solidex indirect composite).

View Article and Find Full Text PDF

Unlabelled: Cell culture system has been used to evaluate alloy cytotoxicity under different environments, testing the extracts, but the effect of temperature variation on the cytotoxicity of dental alloys has not been analyzed.

Objective: The aim of the present study was to investigate if temperature variation could affect dental alloy cytotoxicity, testing alloy extracts in an epithelial cell culture system.

Material And Methods: Discs of Ni-Cr, Co-Cr-Mo, Ni-Cr-Ti, Ti-6Al-4V and commercially pure titanium (cp Ti) were cast by arc melting, under argon atmosphere, injected by vacuum-pressure.