Background: We used speckle-tracking echocardiography to test the hypothesis that regional left ventricular (LV) strain would improve during optimized biventricular pacing (BiVP) in acute right ventricular (RV) pressure overload (PO).
Materials And Methods: Complete heart block and RVPO were induced in five open-chest fully anesthetized pigs. BiVP was optimized by adjusting atrioventricular and interventricular delays to maximize cardiac output derived from an aortic flow probe.