Rationale: After the detection of low concentrations of prednisolone in racehorse urine samples collected at Italian racetracks, a study was initiated to investigate the accuracy of the analytical protocol used and the possible endogenous origin of detected prednisolone.
Methods: Multiple reaction monitoring (MRM) MS(2) acquisition with a triple quadrupole (n = 780) and full scan MS(2) and MS(3) (n = 180) acquisition with a linear ion trap were checked. As a further confirmation, ten urine samples were analysed by high-resolution mass spectrometry (HRMS).