This report details a challenging case of difficult extubation due to a lodged tracheal tube following surgery, presenting an unexpected and complex clinical situation. An inspection of the airway using videolaryngoscopy revealed an over-inflated cuff beneath the vocal cords. Initial efforts to deflate the cuff with various methods were unsuccessful.