Publications by authors named "Maria Jesus Suarez-Garcia"

Immediate full-arch loading is a highly complex and technique-sensitive procedure. Digital impression techniques aim to replace conventional analog systems to carry out dental treatments in a more predictive, safer, and less time-consuming way. This case report describes a patient with a guarded periodontal prognosis, who was rehabilitated with implant-supported fixed prostheses after full-mouth extractions.

View Article and Find Full Text PDF

The aim of this systematic review was to evaluate the in vitro accuracy of dental implants impressions taken with intraoral scanner compared with impressions taken with conventional techniques. Two independent reviewers conducted a systematic electronic search in the PubMed, Web of Science and Scopus databases. Some of the employed key terms, combined with the help of Boolean operators, were: "dental implants", "impression accuracy", "digital impression" and "conventional impression".

View Article and Find Full Text PDF

The aim of this clinical report is to describe a maxillary full-arch implant supported restoration with immediate loading performed by means of an entirely digital work flow with photogrammetric system and intraoral scanning. A female patient with an edentulous maxillary arch attended the dental clinic seeking a maxillary fixed restoration. After treatment planning, 6 implants were placed using a surgical splint fabricated digitally by intraoral scanning of her previous removable prosthesis.

View Article and Find Full Text PDF

Ehlers-Danlos syndromes (EDS) are a group of diverse hereditary connective tissue disorders. Various EDS subtypes present as different diseases. Periodontitis of early onset is a major criterion of periodontal EDS (pEDS).

View Article and Find Full Text PDF

This case report describes the conservative management of generalised tetracycline stains by means of the injectable composite resin technique. This time-efficient technique obtained optimal and satisfactory aesthetic outcomes. Both the patient and the clinician were very satisfied with the results.

View Article and Find Full Text PDF

Background: This systematic review aimed to evaluate the efficiency and accuracy of digital impression techniques for implant-supported restorations, and to assess their economic feasibility.

Material And Methods: Two independent electronic database searches were conducted in the Pubmed/MedLine, Cochrane Library, and Lilacs databases complimented by a manual search, selecting relevant clinical and studies published between 1st January 2009 and 28st February 2019. All type of studies ( and ) were included in this systematic review.

View Article and Find Full Text PDF

Objectives:  The aim of this study was to establish the prevalence of supernumerary teeth (ST) in a sector of the population of Madrid, as well as possible complications associated with the presence of these teeth.

Materials And Methods:  The study investigated patients ( = 28,114) who sought dental care at the Oral Surgery Service of three different centers between May 2005 and April 2018. Cases that did not present this numeric dental developmental variation were discarded, registering only those presenting ST.

View Article and Find Full Text PDF

Objectives: This study aims to evaluate the fracture load of differently fabricated 3-unit posterior fixed dental prostheses (FDPs) with an intermediate pontic.

Methods: Fifty sets of two stainless-steel abutments were randomly assigned to five groups (n = 10 each) depending on the material and technique used for manufacturing the FDPs: (1) Metal-ceramic (MC, control); (2) Lava Zirconia (LZ, bi-layered); (3) Lava Plus (LM, monolithic); (4) VITA In-Ceram YZ (YZ, bi-layered); and (5) IPS e-max ZirCAD (ZZ, bi-layered). After being luted to the dies, all FDPs were submitted to thermo-mechanical cycling (120,000 masticatory cycles, 50 N; plus 774 thermal cycles of 5 °C/55 °C, dwell time: 30 s).

View Article and Find Full Text PDF

Purpose: To evaluate the current status of all-ceramic inlay-retained fixed dental prostheses (CIR-FDPs) for the replacement of posterior teeth.

Study Selection: Screening of titles and abstracts, full-text analysis for inclusion eligibility, quality assessment, data extraction and evaluation of the scientific evidence were performed independently by two reviewers. The electronic databases MEDLINE/PubMed, EMBASE, Cochrane Central Register of Controlled Trials, and Compludoc were searched with no restriction to publication date or language.

View Article and Find Full Text PDF

Objectives: To validate the 'Quality of Life related to function, aesthetics, socialization, and thoughts about health-behavioural habits (QoLFAST-10)' questionnaire for assessing the whole concept of oral health-related quality of life (OHRQoL) of implant-supported fixed partial denture (FPD) wearers.

Methods: 107 patients were assigned to: Group 1 (HP; n=37): fixed-detachable hybrid prostheses (control); Group 2 (C-PD, n=35): cemented partial dentures; and Group 3 (S-PD, n=35): screwed partial dentures. Patients answered the QoLFAST-10 and the Oral Health Impact Profile (OHIP-14sp) scales.

View Article and Find Full Text PDF

Purpose: To evaluate the fracture load of 3-unit zirconia-based posterior fixed dental prostheses (FDPs) before and after veneering the frameworks.

Materials And Methods: Forty standardized stainless-steel master dies were fabricated (height: 5 mm, convergence: 6º, chamfer: 1 mm) and randomly screwed in pairs onto metal bases. The bases were randomly divided into two groups (n = 20 each) according to the zirconia CAD/CAM system used for constructing 3-unit structures for FDPs: group 1 (L): Lava All-ceramic, group 2 (Z): IPS e.

View Article and Find Full Text PDF

Objectives: To validate a new index for assessing the whole concept of oral health-related quality of life (OHRQoL) of implant-prosthesis wearers.

Methods: 113 patients who were not requesting dental treatment were assigned to: Group 1 (CD; n=38): complete denture users (control); Group 2 (IO; n=38): implant overdenture wearers; and Group 3 (HP; n=37): hybrid implant prosthesis users. Patients answered the newly-designed 'Quality of Life related to Function, Aesthetics, Socialization, and Thoughts about health-behavioural habits' (QoLFAST-10) and the Oral Health Impact Profile (OHIP-20sp) questionnaires.

View Article and Find Full Text PDF

Objectives: The aim of this study was to identify the most appropriate alloy composition and melting technique by evaluating the marginal accuracy of cast metal-ceramic crowns.

Methods: Seventy standardised stainless-steel abutments were prepared to receive metal-ceramic crowns and were randomly divided into four alloy groups: Group 1: palladium-gold (Pd-Au), Group 2: nickel-chromium-titanium (Ni-Cr-Ti), Group 3: nickel-chromium (Ni-Cr) and Group 4: titanium (Ti). Groups 1, 2 and 3 were in turn subdivided to be melted and cast using: (a) gas oxygen torch and centrifugal casting machine (TC) or (b) induction and centrifugal casting machine (IC).

View Article and Find Full Text PDF

Objectives: To investigate the differences in impact on oral health-related quality of life (OHRQoL) among complete denture wearers depending on their socio-demographic characteristics, prosthetic-related factors and oral status.

Study Design: 51 patients aged 50-90 years treated, from 2005 to 2010, with at least one complete denture at the Department of Buccofacial Prostheses of the Complutense University (Madrid) were enrolled in this cross-sectional study. All of the participants answered the Oral Health Impact Profile (OHIP-14sp) questionnaire.

View Article and Find Full Text PDF

Objectives: This study evaluated the marginal misfit and microleakage of cement-retained implant-supported crown copings.

Methods: Single crown structures were constructed with: (1) laser-sintered Co-Cr (LS); (2) vacuum-cast Co-Cr (CC) and (3) vacuum-cast Ni-Cr-Ti (CN). Samples of each alloy group were randomly luted in standard fashion onto machined titanium abutments using: (1) GC Fuji PLUS (FP); (2) Clearfil Esthetic Cement (CEC); (3) RelyX Unicem 2 Automix (RXU) and (4) DentoTemp (DT) (n=15 each).

View Article and Find Full Text PDF

Objectives: To evaluate the incidence of prosthetic complications in implant-retained crowns made with UCLA castable abutments and to identify possible risk factors with a view to establishing recommendations to help predict the success of such restorations.

Methods: A cohort follow-up study was carried out in 71 partially dentate patients rehabilitated with 93 implant-retained single crowns. Data regarding socio-demographic background, anatomical features, implant-, and prosthesis-related variables were recorded.

View Article and Find Full Text PDF

Objectives: To evaluate the oral health-related quality of life (OHRQoL) of implant-retained overdenture users.

Methods: 63 patients aged 50-90 years treated with at least one implant overdenture at the Complutense University (Madrid) in 2000-2010 were included. Of those, 42 answered the Oral Health Impact Profile (OHIP-14 sp) questionnaire.

View Article and Find Full Text PDF

Objectives: This study aimed to evaluate the vertical discrepancy of implant-supported crown structures constructed with vacuum-casting and Direct Metal Laser Sintering (DMLS) technologies, and luted with different cement types.

Study Design: Crown copings were fabricated using: (1) direct metal laser sintered Co-Cr (LS); (2) vacuum-cast Co-Cr (CC); and (3) vacuum-cast Ti (CT). Frameworks were luted onto machined implant abutments under constant seating pressure.

View Article and Find Full Text PDF

This study evaluated the vertical discrepancy of implant-fixed 3-unit structures. Frameworks were constructed with laser-sintered Co-Cr, and vacuum-cast Co-Cr, Ni-Cr-Ti, and Pd-Au. Samples of each alloy group were randomly luted in standard fashion using resin-modified glass-ionomer, self-adhesive, and acrylic/urethane-based cements (n = 12 each).

View Article and Find Full Text PDF