Publications by authors named "Maria Fernanda Sola Ruiz"

Background And Purpose: Provisional prostheses in restorations over several implants with immediate loading in completely edentulous patients increase the risk of frequent structural fractures. An analysis was performed of the resistance to fracture of prosthetic structures with cantilevers using graphene-doped polymethyl methacrylate (PMMA) resins and CAD-CAM technology.

Methods: A master model was produced with four implants measuring 4 mm in diameter and spaced 3 mm apart, over which 44 specimens representing three-unit fixed partial prostheses with a cantilever measuring 11 mm were placed.

View Article and Find Full Text PDF

Background: This systematic review and meta-analysis aimed to evaluate the wear of the antagonist tooth in ceramic restorations.

Material And Methods: This study was carried out based on Preferred Reporting Items for Systematic Review and Meta-analysis (PRISMA) recommendations; it was also registered in PROSPERO (register number: CRD42022316252). Three databases were consulted in the literature search, Embase, Scopus, and Web of Science.

View Article and Find Full Text PDF

Objective: The main objective of this study aimed to evaluate the response to treatment in implants with peri-implantitis regarding the presence or absence of keratinized mucosa.

Materials And Methods: One hundred implants with peri-implantitis were treated non-surgically at the Prosthodontics and Occlusion Teaching Unit of the University of Valencia. Records were registered at day zero (recession, bleeding on probing, suppuration, probing depth, bone loss and plaque index), at 1, 3 and 6 months.

View Article and Find Full Text PDF

Objective: The aim of the systematic review and meta-analysis carried out was to evaluate the effects of changing the prosthetic platform on peri-implant tissue after 1 year of prosthetic loading.

Material And Methods: In November 2020, an electronic search was carried out in PubMed, EMBASE, Web of Science, and Scopus databases with the aim of obtaining all the randomized clinical trials that had been published in the preceding 10 years comparing the effects on the peri-implant tissue of implants with a prosthetic platform change and implants with a conventional platform for at least 1 year after prosthetic loading. Randomized model meta-analyses of the selected studies were performed to compare the results of the two implant groups in terms of vertical maintenance of bone level and increased probing depth.

View Article and Find Full Text PDF

Statement Of Problem: One of the most frequent complications in participants with fixed partial dentures (FPDs) is the apical migration of the gingival margin, which may be associated with factors such as fit, gingival margin location, or tooth preparation type. The prevalence of the complication in participants restored with FPDs prepared by using the biologically oriented preparation technique (BOPT) is unclear.

Purpose: The purpose of this prospective clinical trial was to evaluate the clinical and biologic outcomes of FPDs on teeth prepared by using the BOPT, over a 6-year follow-up period.

View Article and Find Full Text PDF

Objectives: The aim of this study was to analyze the behavior of the periodontal tissues around teeth in the anterior region when restored with zirconia single crowns, using a biologically oriented preparation technique (BOPT), over a 6-year follow-up.

Methods: The study investigated tooth-supported single crowns in the anterior region that were fabricated with a zirconia core and feldspathic ceramic covering, in 34 patients. Follow-up analysis took place annually for 6 years, assessing periodontal responses by evaluating the following variables: plaque index (PI); probing depth (PD); gingival index (GI); gingival thickness adjacent to the restoration; and stability of the gingival margin (MS).

View Article and Find Full Text PDF
Article Synopsis
  • - The systematic review aimed to explore how the chemical makeup and thickness of monolithic zirconia affect its optical and mechanical properties, using meta-analysis to assess the roles of yttrium and aluminum percentages and specimen thickness.
  • - Following PRISMA guidelines, researchers searched databases for relevant studies published in the last decade, ultimately selecting 26 articles for qualitative synthesis and 24 for quantitative analysis, ensuring the quality of experimental studies was assessed.
  • - The results indicated significant impacts of yttrium, aluminum, and thickness on zirconia's properties, with greater variability observed, which could inform clinicians on selecting appropriate zirconia types for different dental restorations.
View Article and Find Full Text PDF

Introduction: The aim of this retrospective study was to analyze the radiographic peri-implant bone loss of bone level implants and tissue level implants with a convergent neck in screw-retained single crowns and in screw-retained fixed partial prostheses, after two years of functional loading.

Materials And Methods: The sample was divided into two groups according to their type: Group I: supracrestal implants with convergent transmucosal neck; Group II: crestal implants. In each group we distinguish two subgroups according to the type of prosthetic restoration: single crowns and a three-piece fixed partial prosthesis on two implants.

View Article and Find Full Text PDF

Statement Of Problem: Rehabilitation of edentulous patients with severe maxillary atrophy is a clinical challenge. Although several treatment options are available, the implant-supported overdenture has been widely advocated. However vertical insertion implant-supported overdentures have drawbacks, including wear, aging, and the continuous maintenance of retention systems.

View Article and Find Full Text PDF

Statement Of Problem: Anterior veneered zirconia partial fixed dental prostheses (FDPs) have substituted for metal-ceramic to improve esthetics and biocompatibility. However, the material is susceptible to aging or hydrothermal degradation and to chipping of the feldspathic veneer. Whether these susceptibilities limit the clinical performance of anterior veneered zirconia FPDs is unclear.

View Article and Find Full Text PDF

Objective: To evaluate the influence of implant length on marginal bone loss, comparing implants of 4 mm, 6 mm, and >8 mm, supporting two splinted crowns after 36-month functional loading.

Materials And Methods: this retrospective clinical trial evaluated the peri-implant behavior of splinted crowns (two per case) on pairs of implants of the same length placed in the posterior maxilla (molar area). Implants were divided into three groups according to length (Group 1: extra-short 4 mm; Group 2: short 6 mm; Group 3: conventional length >8 mm).

View Article and Find Full Text PDF

A systematic review and meta-analysis was performed to analyze the survival of onlay restorations in the posterior region, their clinical behavior according to the material used (ceramic reinforced with lithium disilicate, conventional feldspathic ceramic or reinforced with leucite; hybrid materials and composite), possible complications, and the factors influencing restoration success. The systematic review was based on the preferred reporting items for systematic reviews and meta-analyses (PRISMA) statement, without publication date or language restrictions. An electronic search was made in the PubMed, Scopus, Embase, and Cochrane databases.

View Article and Find Full Text PDF

Background: The aim of this systematic review and meta-analysis was to determine the wear sustained in the natural antagonist tooth in cases of full-coverage fixed-base prosthetic restorations or monolithic zirconia tooth-supported crowns, as well as to determine the wear in the restoration itself, both in the short- and medium-term and considering the factors that may influence wear.

Material And Methods: A systematic literature review and meta-analysis, based on Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) recommendations, of clinical studies that evaluated wear in antagonist teeth in relation to fixed-prosthesis monolithic zirconia crowns. A total of 5 databases were consulted in the literature search: Pubmed-Medline, Cochrane, Scopus, Embase and Web of Science (WOS).

View Article and Find Full Text PDF

To compare the medium- to long-term mechanical behavior of overdentures with two different retention systems: overdentures with Locator® axial retention, and vertical insertion overdentures with bar retention, used to rehabilitate edentulous maxillar. This prospective study assessed patients presenting complete maxillary edentulism, rehabilitated by means of implant-supported overdentures ( = 20), 10 with Locator® axial retention (ODA group) and 10 with overdentures on bars (ODB group). Patients also completed a questionnaire to determine their satisfaction with treatment.

View Article and Find Full Text PDF

Background: The objective of this systematic review and meta-analysis was to analyze the periodontal behavior around teeth prepared with horizontal finishing crowns supporting fixed metal-ceramic and zirconia full coverage crowns and fixed partial dentures (FDPs).

Materials And Methods: An electronic search was conducted to locate relevant clinical trials in four databases: PubMed, Embase, Cochrane, and Scopus. A manual search was made in the reference sections of the articles identified for any additional articles.

View Article and Find Full Text PDF

: The objective of this prospective randomized clinical trial (RCT) was to analyze and compare the clinical behavior of three types of prosthesis supported by single implants in the posterior region after three years of functional loading. : Seventy-five implants were divided into three groups according to the type of prosthetic restoration: screw-retained crown (group GS); cemented crown without finishing line (biologically oriented preparation technique) (group GBOPT); and conventional cemented crown with finishing line (group GCC). After three years in function, clinical parameters (presence of keratinized mucosa, probing depths, bleeding on probing, and radiographic bone loss) were compared between the three experimental groups.

View Article and Find Full Text PDF

Purpose: The objective of this prospective randomized clinical trial (RCT) was to analyze and compare the clinical behavior of three types of prosthesis supported by single implants in the posterior region after three years functional loading.

Materials And Methods: Seventy-five implants were divided into three groups according to the type of prosthetic restoration: screw-retained crown (Group GS); cemented crown without finishing line (biologically oriented preparation technique) (Group GBOPT); and conventional cemented crown with finishing line (Group GCC). The clinical behavior of each restoration type was analyzed after 3 years functional loading by analyzing radiographic peri-implant bone loss.

View Article and Find Full Text PDF

Background: The aim of this systematic review and meta-analysis was to determine the fracture resistance and survival rate of partial indirect restorations inlays, onlays, and overlays fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) technology from ceramics, composite resin, resin nanoceramic, or hybrid ceramic and to analyze the influence of proximal box elevation on fracture resistance.

Materials And Methods: This systematic review was based on guidelines proposed by the preferred reporting items for systematic reviews and meta-analyses (PRISMA). An electronic search was conducted in databases US National Library of Medicine National Institutes of Health (PubMed), Scopus, Web of Science (WOS), and Embase.

View Article and Find Full Text PDF

Purpose: To analyze in vitro the mechanical behavior of five types of complete coverage crowns fabricated from different materials.

Materials And Methods: Seventy-five full coverage crowns were divided into five groups according to material: Group I, metal core with feldspathic ceramic covering (MC- control group); Group II, zirconia core with feldspathic ceramic covering (CZ); Group III, tetragonal monolithic zirconia (TMZ); Group IV, cubic monolithic zirconia (CMZ); Group V, high molecular weight polymethyl methacrylate (PMMAG) doped with graphene nanoparticles. All crowns underwent in vitro fatiguing by dynamic loading in wet conditions to simulate the masticatory forces to which prosthodontic materials are subject in the oral medium.

View Article and Find Full Text PDF

The purpose of the investigation was to analyze fracture resistance and mode of failure of zirconium oxide (zirconia) abutments placed on dental implants bearing crowns of different esthetic materials: zirconia, lithium disilicate (LDS), and nano-ceramic resin, for replacing single teeth in the anterior sector. Eighty implant-abutment-crown units were divided into four groups: Group T-MC (control): 20 metal-ceramic crowns cemented onto titanium abutments; Group Z-Z: 20 zirconia crowns on zirconia abutments; Group Z-LD: 20 lithium disilicate crowns on zirconia abutments; and Group Z-NCR: 20 nano-ceramic resin crowns on zirconia abutments. Specimens underwent a fatiguing process (dynamic loading and thermocycling), followed by static loading to evaluate mechanical fracture resistance, and the mode of failure produced.

View Article and Find Full Text PDF

Background: To evaluate color changes to composite resins used to restore extracted teeth compared with composite discs after whitening with two agents: hydrogen peroxide (HP) and carbamide peroxide (CP).

Material And Methods: Ten human molars with class V vestibular and palatine cavity preparation obturated with Vita hybrid nanocomposite were hemisected to obtain 20 specimens assigned randomly to two groups: O1 and O2. Twenty composite discs were divided into two groups: D1 and D2.

View Article and Find Full Text PDF

Purpose: To evaluate the influence of static (not preloaded) and thermomechanical loading on the load to fracture of metal-ceramic, monolithic and veneered zirconia computer-aided design/computer-aided manufacturing (CAD/CAM) posterior fixed partial dentures (FPDs).

Materials And Methods: One hundred standardized specimens with 2 abutments screwed onto a platform were prepared from stainless steel to receive a posterior 3-unit FPD with an intermediate pontic. Specimens were randomly divided into 5 groups (n = 20): Metal-ceramic (control group), Lava Zirconia system, Vita In-Ceram YZ, IPS e.

View Article and Find Full Text PDF

Purpose: To quantify the rate of maintenance interventions of mandibular prostheses: complete dentures and overdentures retained by two implants, with either internal hex or external hex connections.

Materials And Methods: This study analyzed patients with edentulous mandibles treated with distinct treatment protocols: a control group received complete dentures; a second group received Locator-retained overdentures supported by two external hex connection implants; and a third group received overdentures supported by internal hex connection implants. All of the maintenance interventions associated with the prosthetic treatment after delivery were recorded (starting from 2000 until the final assessment in 2012).

View Article and Find Full Text PDF

Purpose: The aim of this study was to evaluate the mechanical behavior of implant-supported cemented restorations placed on two types of abutment design, with and without a prosthetic finish line, evaluating fracture resistance and the type of fracture produced in the abutment-crown complex.

Materials And Methods: Eighty zirconia restorations supported by tapered implants were divided into two groups: group I, with 40 zirconia crowns cemented onto individualized zirconia abutments with a chamfered finish line (1 mm deep); and group II, with 40 zirconia crowns cemented onto individualized zirconia abutments without a finish line. All specimens underwent thermocycling and dynamic loading before static load testing to evaluate their fracture resistance.

View Article and Find Full Text PDF

Unlabelled: Recent years have seen increasing demand for treatments aimed at improving dental esthetics. In this context, both patients and dentists prefer to preserve dental structures as far as possible; thanks to technological advances, especially in adhesive dentistry, new materials and minimally invasive techniques such as "no-prep" (no preparation) veneers have made this possible. Nevertheless, no-prep veneers have specific indications and suffer certain disadvantages.

View Article and Find Full Text PDF