This review article aims to synthesize existing data on radiation-induced heart diseases in patients undergoing chest radiation therapy and also explores cardiac-sparing techniques to mitigate cardiotoxic effects. We conducted a comprehensive database search to review and consolidate data regarding chest radiotherapy and effects on the heart as well as techniques to minimize exposure to the heart. The research findings demonstrate associations between radiation exposure to cardiac substructures and subsequent cardiotoxicity.

View Article and Find Full Text PDF

Background And Purpose: The upgrade of major equipment can be disruptive to clinical operations and introduce risk as policy and procedures need to adapt to new technical possibilities and constraints. We describe here the transition from GammaMedPlus-iX to Bravos in a busy brachytherapy clinic, involving four afterloaders across two sites.

Material And Methods: Our clinic employs three high-dose-rate remote afterloaders in four dedicated treatment vaults at the main site and a fourth afterloader at a regional location.

View Article and Find Full Text PDF
Article Synopsis
  • - The study introduces a new calibration method to address signal drift in Respiratory Gating for Scanner systems, specifically when using a wall-mounted camera and dealing with table sagging.
  • - The calibration involved simulating a patient's weight using solid water phantoms and measuring at various points around the CT isocenter in two hospitals.
  • - Results showed that the new method significantly reduced signal drift during scans, enhancing accuracy in radiation delivery for patients, particularly those with higher body weight.
View Article and Find Full Text PDF

Background: EBT4 was newly released for radiotherapy quality assurance to improve the signal-to-noise ratio in radiochromic film dosimetry. It is important to know its dose-response characteristics before its use in the clinic.

Purpose: This study aims to investigate and compare the dose-response curves of the Gafchromic EBT4 film for megavoltage and kilovoltage x-ray beams with different dose levels, scanning spatial resolutions, and sizes of region of interest (ROI).

View Article and Find Full Text PDF

Purpose: End-to-end testing (E2E) is a necessary process for assessing the readiness of the stereotactic radiosurgery (SRS) program and annual QA of an SRS system according to the AAPM MPPG 9a. This study investigates the differences between using a new SRS MapCHECK (SRSMC) system and an anthropomorphic phantom film-based system in a large network with different SRS delivery techniques.

Methods And Materials: Three SRS capable Linacs (Varian Medical Systems, Palo Alto, CA) at three different regional sites were chosen to represent a hospital network, a Trilogy with an M120 multi-leaf collimator (MLC), a TrueBeam with an M120 MLC, and a TrueBeam Stx with an HD120 MLC.

View Article and Find Full Text PDF

Background: Intensity-modulated radiation therapy (IMRT) and volume-modulated arc therapy (VMAT) are rather complex treatment techniques and require patient-specific quality assurance procedures. Electronic portal imaging devices (EPID) are increasingly used in the verification of radiation therapy (RT). This work aims to develop a novel model to predict the EPID transmission image (TI) with fluence maps from the RT plan.

View Article and Find Full Text PDF

Purpose: This review article aims to consolidate information regarding existing and emerging implanted devices used in patients undergoing radiation therapy and to categorize levels of attention needed for each device, including which devices require monitoring throughout treatment.

Methods And Materials: Based on the collective information from scholar searches, manufacturers' technical reports, and institutional experiences in the past years, commonly present devices in patients with cancer are compiled. This work summarizes cardiac pacemaker, implanted cardiac defibrillator, hepatic pump, intrathecal pain pump, neurostimulator, shunt, loop recorder, and mediport.

View Article and Find Full Text PDF

Background And Purpose: To commission and implement an Autoencoder based Classification-Regression (ACLR) model for VMAT patient-specific quality assurance (PSQA) in a multi-institution scenario.

Materials And Methods: 1835 VMAT plans from seven institutions were collected for the ACLR model commissioning and multi-institutional validation. We established three scenarios to validate the gamma passing rates (GPRs) prediction and classification accuracy with the ACLR model for different delivery equipment, QA devices, and treatment planning systems (TPS).

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate and compare different system calibration methods from a large cohort of systems to establish a commissioning procedure for surface-guided frameless cranial stereotactic radiosurgery (SRS) with intrafractional motion monitoring and gating. Using optical surface imaging (OSI) to guide non-coplanar SRS treatments, the determination of OSI couch-angle dependency, baseline drift, and gated-delivered-dose equivalency are essential.

Methods: Eleven trained physicists evaluated 17 OSI systems at nine clinical centers within our institution.

View Article and Find Full Text PDF

The use of machine learning and other sophisticated models to aid in prediction and decision making has become widely popular across a breadth of disciplines. Within the greater diagnostic radiology, radiation oncology, and medical physics communities promising work is being performed in tissue classification and cancer staging, outcome prediction, automated segmentation, treatment planning, and quality assurance as well as other areas. In this article, machine learning approaches are explored, highlighting specific applications in machine and patient-specific quality assurance (QA).

View Article and Find Full Text PDF

Patient-specific quality assurance (PSQA) of volumetric modulated arc therapy (VMAT) to assure accurate treatment delivery is resource-intensive and time-consuming. Recently, machine learning has been increasingly investigated in PSQA results prediction. However, the classification performance of models at different criteria needs further improvement and clinical validation (CV), especially for predicting plans with low gamma passing rates (GPRs).

View Article and Find Full Text PDF

The use of radiochromic film (RCF) dosimetry in radiation therapy is extensive due to its high level of achievable accuracy for a wide range of dose values and its suitability under a variety of measurement conditions. However, since the publication of the 1998 AAPM Task Group 55, Report No. 63 on RCF dosimetry, the chemistry, composition, and readout systems for RCFs have evolved steadily.

View Article and Find Full Text PDF

Purposes: The newly released Protura 6 degrees-of-freedom couch (CIVCO) has limited quality assurance protocols and pertinent publications. Herein, we report our experiences of the Protura system acceptance, commissioning, and quality assurance.

Methods: The Protura system integration was tested with peripheral equipment on the following items: couch movement range limit, 6 degrees-of-freedom movement accuracy, weight test and couch sagging, system connection with Linac, isocentricity of couch and rotation alignment, kV and cone-beam computed tomography imaging of HexaCHECK with MIMI phantom (Standard Imaging), and an in-house custom 6 degrees-of-freedom quality assurance phantom.

View Article and Find Full Text PDF

Purpose: To assess the accuracy of machine learning to predict and classify quality assurance (QA) results for volumetric modulated arc therapy (VMAT) plans.

Methods And Materials: Three hundred three VMAT plans, including 176 gynecologic cancer and 127 head and neck cancer plans, were chosen in this study. Fifty-four complexity metrics were extracted from the QA plans and considered as inputs.

View Article and Find Full Text PDF

This study aimed to investigate the impact of delivery characteristics on the dose delivery accuracy of volumetric modulated arc therapy (VMAT) for different treatment sites. The pretreatment quality assurance (QA) results of 344 VMAT patients diagnosed with gynecological (GYN), head and neck (H&N), rectal or prostate cancer were randomly chosen in this study. Ten metrics reflecting VMAT delivery characteristics were extracted from the QA plans.

View Article and Find Full Text PDF

Objective: The goal of the present study was to calculate the continuous slowing down approximation (CDSA) ranges and derive mass stopping power for EBT3 and EBT-XD films for therapeutic protons energy ranges of 50-400 MeV.

Methods: The MCNPX and TRansport of Ions in Matter (TRIM) Monte Carlo codes were used in this study. Utilizing the published International Commission on Radiation Units and Measurement 49 data for the water mass stopping power and CSDA ranges, the mass stopping powers of EBT3 and EBT-XD films were derived using the approximation proposed by Newhauser and Zhang in 2009.

View Article and Find Full Text PDF

Radiation therapy of thoracic and abdominal tumors requires incorporating the respiratory motion into treatments. To precisely account for the patient's respiratory motions and predict the respiratory signals, a generalized model for predictions of different types of patients' respiratory motions is desired. The aim of this study is to explore the feasibility of developing a long short-term memory (LSTM)-based generalized model for the respiratory signal prediction.

View Article and Find Full Text PDF

Purpose: To validate a machine learning approach to Virtual intensity-modulated radiation therapy (IMRT) quality assurance (QA) for accurately predicting gamma passing rates using different measurement approaches at different institutions.

Methods: A Virtual IMRT QA framework was previously developed using a machine learning algorithm based on 498 IMRT plans, in which QA measurements were performed using diode-array detectors and a 3%local/3 mm with 10% threshold at Institution 1. An independent set of 139 IMRT measurements from a different institution, Institution 2, with QA data based on portal dosimetry using the same gamma index, was used to test the mathematical framework.

View Article and Find Full Text PDF

Radiochromic film for spot-scanning QA provides high spatial resolution and efficiency gains from one-shot irradiation for multiple depths. However, calibration can be a tedious procedure which may limit widespread use. Moreover, since there may be an energy dependence, which manifests as a depth dependence, this may require additional measurements for each patient.

View Article and Find Full Text PDF

Over half of cancer patients receive radiotherapy (RT) as partial or full cancer treatment. Daily quality assurance (QA) of RT in cancer treatment closely monitors the performance of the medical linear accelerator (Linac) and is critical for continuous improvement of patient safety and quality of care. Cumulative longitudinal QA measurements are valuable for understanding the behavior of the Linac and allow physicists to identify trends in the output and take preventive actions.

View Article and Find Full Text PDF

Data visualization technique was applied to analyze the daily QA results of photon and electron beams. Special attention was paid to any trend the beams might display. A Varian Trilogy Linac equipped with dual photon energies and five electron energies was commissioned in early 2010.

View Article and Find Full Text PDF

Purpose: The new radiochromic film, GAFChromic EBT-XD, contains the same active material, lithium-10,12-pentacosadiynoate, as GAFChromic EBT3, but the crystalline form is different. This work investigates the effect of this change on the well-known lateral response artifact when EBT-XD film is digitized on a flatbed scanner.

Methods: The dose response of a single production lot of EBT-XD was characterized by scanning an unexposed film plus a set of films exposed to doses between 2.

View Article and Find Full Text PDF