This study aimed to evaluate the initial clinical outcomes of and patient satisfaction with the newly introduced extended monofocal Evolux™ intraocular lens following cataract surgery. A retrospective study was conducted, involving 18 patients (36 eyes) who received Evolux™ lenses bilaterally. The inclusion criteria comprised individuals over 40 years old with no active eye diseases, excluding cataracts, and no postoperative complications.
View Article and Find Full Text PDFPurpose: The aim of this study was to describe our technique for performing femtosecond laser (FSL)-assisted mushroom configuration in deep anterior lamellar keratoplasty (DALK).
Methods: We describe our surgical technique for a mushroom-configuration DALK using a femtosecond laser (FSL) both to prepare the graft and to perform a precut of the recipient cornea, as well as the steps for the dissection of the recipient cornea and for donor cornea implantation. Moreover, we show the parameters of energy and spot separation and the external and internal diameters as well as the thickness of the external and internal keratotomy.
Purpose: To demonstrate that intense pulsed light therapy (IPL) of the upper and lower eyelids with meibomian gland expression (MGX) is effective in improving dry eye disease due to meibomian gland dysfunction (MGD).
Methods: Patients with ocular discomfort (Ocular Surface Disease Index -OSDI- above 13) and signs of MGD were recruited. All patients underwent OSDI, visual acuity (VA), intraocular pressure, Schirmer test, meibography, non-invasive tear breakup time (NITBUT), slit-lamp examination (corneal and conjunctival staining, hyperemia, gland expressibility, and meibum quality), tear osmolarity and lipid layer thickness.
Purpose: To report our first clinical and patient-reported outcomes in the early postoperative period with a new model of trifocal diffractive intraocular lens (IOL).
Methods: Pilot prospective analysis of the results of 26 eyes of 13 patients (age, 44-79 years) undergoing cataract surgery with implantation of the trifocal diffractive IOL Liberty 677MY (Medicontur Medical Engineering Ltd., Zsámbék, Hungary).
Purpose: To analyze the target induced astigmatism (TIA), surgically induced astigmatism (SIA), difference vector (DV), and correction index (CI) in the correction of astigmatism with phakic lenses, and its influence on visual acuity, and to analyze the safety and efficacy indexes of the correction of high and low power astigmatism with toric phakic lenses.
Design: Retrospective comparative study.
Methods: The medical records of patients that were operated on at the research center during the period were analyzed.