Publications by authors named "Maria Dolores Gil Garcia"

A silica-based MCM-41 mesoporous material functionalized with cyanopropyl groups has been synthesized by cocondensation, characterized and applied to preconcentrate six parabens and three UV filters in river and swimming-pool waters. The analytes were quantified by ultra-high performance liquid chromatography-tandem mass spectrometry, according to the Directive 96/23/EC. Even though matrix effect was negligible, quantification in river water samples with the standard addition approach improved the recoveries obtained using solvent-based and even with matrix-matched calibration.

View Article and Find Full Text PDF

During the last years, declines in honey bee colonies are being registered worldwide. Cholinergic pesticides and their extensive use have been correlated to the decline of pollinators and there is evidence that pesticides act as neuroendocrine disruptors affecting the metabolism of neuropeptides. However, there is a big absence of studies with quantitative results correlating the effect of pesticide exposure with changes on neuropeptides insects, and most of them are conducted under laboratory conditions, typically with individual active ingredients.

View Article and Find Full Text PDF

An analytical method based on online enrichment using coupled-column liquid chromatography with fluorescence detection has been developed to determine marbofloxacin, ciprofloxacin, danofloxacin, enrofloxacin, norfloxacin, lomefloxacin, oxolinic acid, and nalidixic acid at trace levels in surface water. The sample containing the pharmaceuticals was pumped through a short C18 column in such a way that the analytes were retained on the column, whereas polar interferences, eluting at the first of the chromatogram, were discarded to waste. Then, the analytes were transferred by the chromatographic mobile phase to a second C18 analytical column, where they were separated following a conventional chromatography.

View Article and Find Full Text PDF

The potential of online trace enrichment on a highly apolar short column in LC was evaluated for the determination of pyrethroids in river water. Twelve millilitres of water samples, modified with 8 mL ACN (ACN/water 40:60, v/v), were passed through 50 x 4.6 mm ID first separation column packed with 5 microm Hypersil Elite C18.

View Article and Find Full Text PDF

The coupled-column (LC-LC) system, consisting of a first column packed with internal surface reversed phase (ISRP) (50 x 4.6mm ID) and a Chrompack C18 (100 x 4.6 mm ID) as second column, allowed the simultaneous determination of five benzoylurea insecticides in dichloromethane (CH2Cl2) extracts of vegetable samples without any clean-up step.

View Article and Find Full Text PDF