An on-line solid-phase extraction (SPE) method coupled to gas chromatography-mass spectrometry (GC-MS) has been developed for the determination of atenolol (ATN) and propranolol (PRO) in human plasma. The hyphenation of SPE with multisyringe flow injection analysis (MSFIA) allows the simultaneous GC-MS determination of ATN and PRO with high selectivity and sensitivity. On-line preconcentration and derivatisation of the analytes were carried out by means of using restricted access materials (RAM) and microwave (MW) assisted derivatisation reactions with N-methyl-N-(trimethylsilyl) trifluoroacetamide (MSTFA)+1% trimethylchlorosilane (TMCS).
View Article and Find Full Text PDFA fully automated method for the determination of six phthalates in environmental water samples is described. It is based in the novel sample preparation concept of in-syringe dispersive liquid-liquid microextraction, coupled as a front end to GC-MS, enabling the integration of the extraction steps and sample injection in an instrumental setup that is easy to operate. Dispersion was achieved by aspiration of the organic (extractant and disperser) and the aqueous phase into the syringe very rapidly.
View Article and Find Full Text PDFIn this paper, a method was described to determine cocaine (COC) and benzoylecgonine (BZE) in human urine samples by GC-MS detection. The extraction of analytes from urine samples was achieved in an Oasis hydrophilic-lipophilic balance column (20 mmx3.9 mm id, dp=25 microm; Waters, USA), incorporated in a multisyringe flow injection system, used for the sample treatment.
View Article and Find Full Text PDFThis study describes a simple and sensitive column-switching high-performance liquid chromatographic method with UV detection for the determination of Lamotrigine in 50 microL of serum. After solid-phase extraction of Lamotrigine on an Oasis HLB extraction precolumn (20 x 3.9 mm; dp: 25 microm), chromatographic separation was achieved at 30 degrees C on a Chromolith RP-18e column (50 mm x 4.
View Article and Find Full Text PDFColumn-switching high-performance liquid chromatographic (HPLC) method has been developed and validated for quantification of losartan, telmisartan, and valsartan in human urine. Urine samples were diluted on the extraction mobile phase (1:4, v/v) and a volume of 20 microL of this mixture were directly injected onto the HPLC system. The analytes were extracted from the matrix using an on-line solid-phase extraction procedure involving a precolumn packed with 25 microm C(18) alkyl-diol support (ADS), and a solution 2% methanol in 5mM phosphate buffer (pH 3.
View Article and Find Full Text PDFIn this work, a simple strategy for the determination of ethanol in all types of alcoholic beverages using Fourier transform infrared spectrometric detection has been developed. The methodological proposal includes the quantitative on-line liquid-liquid extraction of ethanol with chloroform, through a sandwich type cell equipped with a PTFE membrane, using a two-channel manifold; and direct measurement of the analyte in the organic phase, by means of Fourier transform infrared spectrometry. The quantification was carried out measuring the ethanol absorbance at 877cm(-1)(,) corrected by means of a baseline established between 844 and 929cm(-1).
View Article and Find Full Text PDFIn this work, a flow analysis-hydride generation-gas phase derivative molecular absorption-(UV) spectrophotometric method has been developed for the direct determination of antimony in aqueous and hydro-alcoholic samples. Antimony (III) from undiluted samples is directly transformed into the gaseous stibine (SbH(3)) form by on-line reaction with sodium tetrahydroborate (NaBH(4)) in acidic medium (HCl). The gaseous phase generated is separated from the liquid phase using a commercial gas-liquid separator, and swept - with the help of a carrier gas (N(2)) stream - into a quartz gas cell (10cm pathlength); where the corresponding absorption spectrum is acquired in a continuous mode over the 190-300nm wavelength range, using a conventional spectrophotometer.
View Article and Find Full Text PDFIn this work, the coupling between flow analysis (FA)-vapor phase generation (VPG) and Fourier transform infrared spectrometry (FTIR) has been proposed as a novel and alternative strategy for the determination of nitrite. The analyte was transformed into the gaseous nitric oxide (NO) by on-line reaction with potassium iodide (KI) or ascorbic acid in acidic medium. The gaseous NO generated was transported by means of a N(2) gas carrier stream inside the IR gas cell and the corresponding FTIR spectrum was acquired in a continuous mode.
View Article and Find Full Text PDFFlow analysis offers an inexpensive and versatile means for the automation of analytical procedures and hence it has been incorporated in many different techniques. However, the use of infrared detection in flow analysis systems is not common. Whereas Fourier transform infrared (FTIR) spectroscopic detection has been routinely used in gas chromatography (GC), its use for liquid chromatography, and now for flow analysis, flow injection analysis, or sequential injection analysis, is not frequent.
View Article and Find Full Text PDFA simple and sensitive reversed-phase liquid chromatographic method has been developed for the determination of amikacin (AMK) by derivatization. The method is based on the pre-column derivatization of AMK with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC). The derivatization reaction proceeds in aqueous solution at room temperature with a borate buffer of pH 8.
View Article and Find Full Text PDF