Ventriculoperitoneal (VP) shunts represent a surgical option for patients affected by increased intracranial hypertension when medical management fails or is contraindicated. Complications following implantation include shunt obstruction, infection, over and under drainage, migration or disconnection of the tube, formation of a pseudocyst, and allergy to the silicone tube. We report the case of a 31-year-old woman who presented to the emergency room with nausea and generalized malaise, found to have the distal segment of the VP catheter perforating her gastric wall into the stomach lumen which required surgical intervention.
View Article and Find Full Text PDFWe report the case of a 62-year-old man who presented with a progressive myelopathy secondary to spinal cord compression from an odontoid process fracture and subaxial central canal stenosis. The patient underwent a C1-T2 posterior decompression and instrumented fusion (PCDF) and did well immediately postoperatively. However, on POD1, he developed a right hypoglossal nerve (HN) palsy attributed to direct mechanical compression or injury from the C1 lateral mass screw (LMS), which improved following a revision and screw replacement.
View Article and Find Full Text PDF