Background: The maintenance of marginal bone integrity around dental implants continues to be a clinical challenge. It is still unclear whether loading multiple implant-supported prostheses that have different implant connections influences bone resorption.
Objectives: The aim of this in vitro study was to compare stress distribution around residual edentulous ridges supported by external hexagon (EH) and Morse taper (MT) implants with screw-retained frameworks obtained with the use of different methods.
J Prosthodont
July 2024
Purpose: To evaluate the vertical misfit, stress distribution around dental implants, and cantilever fracture strength of 3-unit implant-supported cantilever fixed partial dentures (FPDs) using frameworks made from different materials and manufacturing techniques.
Materials And Methods: Forty FPDs were fabricated and divided into 5 groups (n = 8) based on the framework material used: LAS Co-Cr (Conventional casting-laser welding); TIG Co-Cr (Conventional casting -TIG welding); OP Co-Cr (Conventional casting-one-piece); CAD Co-Cr (CAD-CAM); and CAD Zr (CAD-CAM ZrO). The vertical misfit was evaluated before porcelain application (T1) and before (T2), and after thermomechanical cycling (T3) by stereomicroscopy.
This study evaluated the vertical misfit, passivity, and stress distribution after tightening the screws of different prosthesis. Two implants were used to simulate the rehabilitation of partially edentulous mandible space from the second premolar to the second molar. 40 three-element screw-retained fixed dental prosthesis with distal cantilever were fabricated and divided into four groups according to the method of production of framework (n = 10): G1 = conventional casting one-piece framework, G2 = conventional casting sectioned and laser welding, G3 = conventional casting sectioned and tungsten inert gas (TIG) welding and G4 = framework obtained by CAD/CAM (computer-aided design/computer-aided manufacturing) system.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
March 2020
Purpose: This study used digital image correlation (DIC) to evaluate the strain transferred by splinted and non-splinted screw-retained fixed partial dentures (FPDs) supported by short and conventional implants.
Material And Methods: Four polyurethane models were fabricated to simulate half of the mandibular arch with acrylic resin replicas of the first premolar. Short (5 mm) and/or conventional (11 mm) implants replaced the second premolar and the first and second molars.
Mater Sci Eng C Mater Biol Appl
December 2017
Purpose: To compare the stress distribution of mandibular full dentures supported with implants according to the bar materials and manufacturing techniques using a qualitative photoelastic analysis.
Material And Methods: An acrylic master model simulating the mandibular arch was fabricated with four Morse taper implant analogs of 4.5×6mm.
Int J Oral Maxillofac Implants
January 2018
Purpose: The aim of this study was to compare the bone stress generated by rehabilitation using regular and short-length Morse taper implants (11 and 5 mm, respectively) in the same context and allied with splinted (SP) and nonsplinted (NSP) prostheses in the posterior area of the mandible using finite element analysis.
Materials And Methods: Three-dimensional geometric models using regular implants (Ø4 × 11 mm) and short implants (Ø4 × 5 mm) were simulated with a left posterior mandible that had the first premolar tooth and all teeth posterior to that premolar removed. The four experimental groups were as follows: Group 1 NSP (two regular implants and one short implant rehabilitated with nonsplinted prostheses), Group 1 SP (two regular implants and one short implant rehabilitated with splinted prostheses), Group 2 NSP (one regular implant and two short implants rehabilitated with nonsplinted prostheses), and Group 2 SP (one regular implant and two short implants rehabilitated with splinted prostheses).
J Craniofac Surg
May 2016
Aims: This study used finite element analysis to compare the biomechanical performance of splinted (SP) and nonsplinted (NSP) prostheses to regular and short length Morse taper implants in the posterior side of the mandible.
Methods: The authors used 3-dimensional geometric models of regular implants (∅4 × 11 mm) and short implants (∅4 × 5 mm) housed in the corresponding bone edges of the posterior left mandibular hemiarch involving tooth 34. The 8 experimental groups were: the control group SP (3 regular implants rehabilitated with SP), group 1SP (2 regular and 1 short implants rehabilitated with SP), group 2SP (1 regular and 2 short implants rehabilitated with SP), group 3SP (3 short implants rehabilitated with SP), the control group NSP (3 regular implants rehabilitated with NSP), group 1NSP (2 and 1 short implants rehabilitated with NSP), group 2NSP (1 regular and 2 short implants rehabilitated with NSP), and group 3NSP (3 short implants rehabilitated with NSP).
This research evaluated the influence of temporary cements (eugenol-containing [EC] or eugenol-free [EF]) on the tensile strength of Ni-Cr copings fixed with self-adhesive resin cement to the metal coronal substrate. Thirty-six temporary crowns were divided into 4 groups (n=9) according to the temporary cements: Provy, Dentsply (eugenol-containing), Temp Cem, Vigodent (eugenol-containing), RelyX Temp NE, 3M ESPE (eugenol-free) and Temp Bond NE, Kerr Corp (eugenol-free). After 24 h of temporary cementation, tensile strength tests were performed in a universal testing machine at a crosshead speed of 0.
View Article and Find Full Text PDFThis study aims to compare stress transmitted to implants and passive fit of one-piece cast frameworks fabricated with 3 different materials: commercially pure titanium (G1-CP Ti), cobalt-chromium alloy (G2-Co-Cr), and nickel-chromium-titanium alloy (G3-Ni-Cr-Ti). In total, 12 frameworks simulating bars for fixed prosthesis in a model with 5 implants were fabricated. The passive fit of the framework interface was measured using an optical microscope and the stresses transmitted to implants were measured using quantitative photoelastic analysis.
View Article and Find Full Text PDFActa Odontol Scand
August 2016
Objectives: To evaluate the effect of thermal cycling and inner surface treatment with aluminum oxide at different granulations on the tensile strength of Ni-Cr copings cemented with different cementing agents.
Materials And Methods: Ninety-six metal copings were manufactured and divided into two groups: before and after thermal cycling (n = 48). The copings of both groups were internally treated by sandblasting with aluminum oxide particles of 100 (n = 24) and 320 (n = 24) mesh.
Casting in the presence of oxygen may result in an improvement of the corrosion performance of most alloys. However, the effect of corrosion on the casting without oxygen for dental materials remains unknown. The aim of this study was to investigate the influence of the casting technique and atmosphere (argon or oxygen) on the corrosion behavior response of six different dental casting alloys.
View Article and Find Full Text PDFThis study aims to investigate a possible correlation between vertical misfits and the stresses transmitted to implants from one-piece casted frameworks fabricated with 3 different materials: commercially pure titanium, cobalt chromium alloy, and nickel chromium titanium alloy. Twelve frameworks simulating screw-retained prosthesis were fabricated from a master cast with 5 implants. Each framework was screwed (20 Ncm) over a metal cast and the vertical mesial and distal misfits were measured using an optical microscope.
View Article and Find Full Text PDFPurpose: The purpose of this study was to determine whether abutment screw tightening and untightening influenced loss of preload in three different implant/abutment interfaces, or on the implant body.
Materials And Methods: Five custom-fabricated machined titanium implants were used, each with its respective abutment, with different connection types, retention screws, and torque values (external hexagon with titanium screw/32 Ncm, external hexagon with coated screw/32 Ncm, internal hexagon/20 Ncm and internal conical/20 and 32 Ncm). Each implant tested had two strain gauges attached and was submitted to five tightening/untightening sequences.
Purpose: The aim was to evaluate the reproducibility of a radiographic technique using a new customized film holder in the follow-up of screwed single-tooth implants.
Materials And Methods: Ten implants placed in the mandible (n = 6) and maxilla (n = 4) of 8 patients were submitted to radiographic assessments. Radiographs were taken using a customized film holder adapted to implant abutment after 4 (T0) and 8 (T1) months of implant placement.
Int J Oral Maxillofac Implants
April 2014
Purpose: This study compared the loosening torque of experimental conical-head abutment screws to that of conventional flat-head screws of implants with external-hex (EH) and internal tri-channel (IT) connections before and after mechanical loading.
Materials And Methods: Forty-four implant/screw/abutment assemblies were divided into four groups: EH/flat-head screw (EH), IT/flat-head screw (IT), EH/conical-head screw (EHCS), and IT/conical-head screw (ITCS). Three assemblies from each group were analyzed in a stereoscopic magnifier and then returned to their respective groups.
J Appl Oral Sci
March 2014
Objective: This study aimed to evaluate the importance of a distal proximal contact on the load transfer to the posterior region of the mandible by non-splinted adjacent implant-supported crowns using photoelastic stress analysis.
Material And Methods: A rectangular model (68x30x15 mm) was made of polymethylmethacrylate resin to simulate half of the mandibular arch. One model was completed with resin replicas representing the first premolar and second molar and with two 3.
Purpose: This finite element analysis (FEA) compared stress distribution on external surface of different morse taper implants, varying implant bodies length and dimensions of metal-ceramic crowns in order to maintain the occlusal alignment.
Methods: Three-dimensional finite element (FE) models were designed representing a posterior left side segment of the mandible: group 0, 3 implants of 11 mm length; group 1, implants of 13 mm, 11 mm and 5mm length; group 2, 1 implant of 11 mm and 2 implants of 5mm length; group 3, 3 implants of 5mm length. The abutments heights were 3.
The effects of fluoride, which is present in different oral hygiene products, deserve more investigation because little is known about their impact on the surface of titanium, which is largely used in Implantology. This study evaluated the surface of commercially pure titanium (cpTi) after exposure to different concentrations of sodium fluoride (NaF). The hypothesis tested in this study was that different concentrations of NaF applied at different time intervals can affect the titanium surface in different ways.
View Article and Find Full Text PDFPurpose: The present study aimed to evaluate the retention and stress distribution of conventional (C) RPD and compare to RPD associated to implant for support (IS) and retention (IR).
Methods: Frameworks were cast from cp Ti (n=18) and Co-Cr alloy (n=18) by plasma and injected by vacuum-pressure. Conventional RPDs were compared to implant associated RPDs using a distal implant to support (IS) or to support and retain (IR) RPD.
J Craniofac Surg
November 2012
This finite element analysis (FEA) compared stress distribution on different bony ridges rehabilitated with different lengths of morse taper implants, varying dimensions of metal-ceramic crowns to maintain the occlusal alignment. Three-dimensional FE models were designed representing a posterior left side segment of the mandible: group control, 3 implants of 11 mm length; group 1, implants of 13 mm, 11 mm and 5 mm length; group 2, 1 implant of 11 mm and 2 implants of 5 mm length; and group 3, 3 implants of 5 mm length. The abutments heights were 3.
View Article and Find Full Text PDFObjectives: The aim of this study was to compare the stresses resulting from cemented or screw-retained dental prostheses using universal cast to long abutment by the photoelastic method.
Material And Methods: A photoelastic resin model was fabricated to simulate a segment of the mandibular arch with resin replicas of a first premolar and a second molar, and two 3.75 × 11-mm implants replacing the second premolar and the first molar.
Purpose: The aim of the present study was to evaluate if a smaller morse taper abutment has a negative effect on the fracture resistance of implant-abutment connections under oblique compressive loads compared to a conventional abutment.
Materials And Methods: Twenty morse taper conventional abutments (4.8 mm diameter) and smaller abutments (3.
Purpose: Adequate passive-fitting of one-piece cast 3-element implant-supported frameworks is hard to achieve. This short communication aims to present an alternative method for section of one-piece cast frameworks and for casting implant-supported frameworks.
Materials And Methods: Three-unit implant-supported nickel-chromium (Ni-Cr) frameworks were tested for vertical misfit (n = 6).
The aim of this study was to determine the effect of the oral environment on the corrosion of dental alloys with different compositions, using electrochemical methods. The corrosion rates were obtained from the current-potential curves and electrochemical impedance spectroscopy (EIS). The effect of artificial saliva on the corrosion of dental alloys was dependent on alloy composition.
View Article and Find Full Text PDFThe present study evaluated microstructure, microhardness and wear resistance of experimental titanium alloys containing zirconium and tantalum. Alloys were melted in arc melting furnace according to the following compositions: Ti-5Zr, Ti-5Ta and Ti-5Ta-5Zr (%wt). Hemispheres and disks were obtained from wax patterns that were invested and cast by plasma.
View Article and Find Full Text PDF