Cell-based therapies have been making great advances toward clinical reality. Despite the increase in trial activity, few therapies have successfully navigated late-phase clinical trials and received market authorization. One possible explanation for this is that additional tools and technologies to enable their development have only recently become available.
View Article and Find Full Text PDFWiley Interdiscip Rev Nanomed Nanobiotechnol
September 2020
Various nanomedicinal products (NMPs) have been reported to induce an adverse immune response, which may be related to their tendency to accumulate in or target cells of the immune system. Therefore, before their market authorization, NMPs should be thoroughly evaluated for their immunotoxic potential. Nonclinical regulatory immunotoxicity testing of nonbiological medicinal products, including NMPs, is currently performed by following the guideline S8 "Immunotoxicity Studies for Human Pharmaceuticals" of the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH).
View Article and Find Full Text PDFOrgans-on-chip (OC) have gained much interest as animal-free toxicity testing methods due to their closer resemblance to human tissues and longer culture viability than conventional in vitro methods. The current paper discusses where and how OCs may take a role in the transition to a more predictive, animal-free safety assessment for regulatory purposes. From a preliminary analysis of a repeated dose toxicity database, ten organs of priority for OC development for regulatory use have been identified.
View Article and Find Full Text PDFThe terms "Safe innovation" and "Safe(r)-by-design" are currently popular in the field of nanotechnology. These terms are used to describe approaches that advocate the consideration of safety aspects already at an early stage of the innovation process of (nano)materials and nanoenabled products. Here, we investigate the possibilities of considering safety aspects during various stages of the innovation process of graphene, outlining what information is already available for assessing potential hazard, exposure, and risks.
View Article and Find Full Text PDFTo study the effects of nanomaterials after inhalation, a large number of in vitro lung models have been reported in literature. Although the in vitro models contribute to the reduction of animal studies, insufficient data exists to determine the predictive value of these in vitro models for the in vivo situation. The aim of this study was to determine the correlation between in vitro and in vivo data by comparing the dose metrics of silver nanoparticles in an in vitro lung model of increasing complexity to our previously published in vivo inhalation study.
View Article and Find Full Text PDFThis paper aimed to clarify whether maternal inhalation of engineered nanoparticles (NP) may constitute a hazard to pregnancy and fetal development, primarily based on experimental animal studies of NP and air pollution particles. Overall, it is plausible that NP may translocate from the respiratory tract to the placenta and fetus, but also that adverse effects may occur secondarily to maternal inflammatory responses. The limited database describes several organ systems in the offspring to be potentially sensitive to maternal inhalation of particles, but large uncertainties exist about the implications for embryo-fetal development and health later in life.
View Article and Find Full Text PDFThe increasing use of nanoparticles in products likely results in increased exposure of both workers and consumers. Because of their small size, there are concerns that nanoparticles unintentionally cross the barriers of the human body. Several in vivo rodent studies show that, dependent on the exposure route, time, and concentration, and their characteristics, nanoparticles can cross the lung, gut, skin, and placental barrier.
View Article and Find Full Text PDFA number of studies have shown that induction of pulmonary toxicity by nanoparticles of the same chemical composition depends on particle size, which is likely in part due to differences in lung deposition. Particle size mostly determines whether nanoparticles reach the alveoli, and where they might induce toxicity. For the risk assessment of nanomaterials, there is need for a suitable dose metric that accounts for differences in effects between different sized nanoparticles of the same chemical composition.
View Article and Find Full Text PDFAim: A horizon scan of nanomedicinal product on the market or undergoing clinical investigation by analyzing the current nanomedicinal landscape.
Materials & Methods: The horizon scan includes a search of literature, clinical trial registries and the internet.
Results: This horizon scan yielded 175 nanomedicinal products.
Traditionally, administered mass is used to describe doses of conventional chemical substances in toxicity studies. For deriving toxic doses of nanomaterials, mass and chemical composition alone may not adequately describe the dose, because particles with the same chemical composition can have completely different toxic mass doses depending on properties such as particle size. Other dose metrics such as particle number, volume, or surface area have been suggested, but consensus is lacking.
View Article and Find Full Text PDFBackground: Although silver nanoparticles are currently used in more than 400 consumer products, it is not clear to what extent they induce adverse effects after inhalation during production and use. In this study, we determined the lung burden, tissue distribution, and the induction and recovery of adverse effects after short-term inhalation exposure to 15 nm and 410 nm silver nanoparticles.
Methods: Rats were nose-only exposed to clean air, 15 nm silver nanoparticles (179 μg/m³) or 410 nm silver particles (167 μg/m³) 6 hours per day, for four consecutive days.
The increasing manufacture and use of products based on nanotechnology raises concerns for both workers and consumers. Various studies report induction of pulmonary inflammation after inhalation exposure to nanoparticles, which can vary in aspects such as size, shape, charge, crystallinity, chemical composition, and dissolution rate. Each of these aspects can affect their toxicity, although it is largely unknown to what extent.
View Article and Find Full Text PDFBecause of its antibacterial activity nanosilver is one of the most commonly used nanomaterials. It is increasingly used in a variety of both medical and consumer products resulting in an increase in human exposure. However, the knowledge on the systemic toxicity of nanosilver is relatively limited.
View Article and Find Full Text PDFSilver nanoparticles are of interest to be used as antimicrobial agents in wound dressings and coatings in medical devices, but potential adverse effects have been reported in the literature. The most pronounced effect of silver nanoparticles and the role of particle size in determining these effects, also in comparison to silver ions, are largely unknown. Effects of silver nanoparticles of different sizes (20, 80, 113 nm) were compared in in vitro assays for cytotoxicity, inflammation, genotoxicity and developmental toxicity.
View Article and Find Full Text PDFWe investigated the potential of four well-characterized amorphous silica nanoparticles to induce chromosomal aberrations and gene mutations using two in vitro genotoxicity assays. Transmission electron microscopy (TEM) was used to verify the manufacturer's nominal size of 10, 30, 80 and 400 nm which showed actual sizes of 11, 34, 34 and 248 nm, respectively. The 80 (34) nm silica nanoparticles induced chromosomal aberrations in the micronucleus assay using 3T3-L1 mouse fibroblasts and the 30 (34) and 80 (34) nm silica nanoparticles induced gene mutations in mouse embryonic fibroblasts carrying the lacZ reporter gene.
View Article and Find Full Text PDFWhile research into the potential toxic properties of nanomaterials is now increasing, the area of developmental toxicity has remained relatively uninvestigated. The embryonic stem cell test is an in vitro screening assay used to investigate the embryotoxic potential of chemicals by determining their ability to inhibit differentiation of embryonic stem cells into spontaneously contracting cardiomyocytes. Four well characterized silica nanoparticles of various sizes were used to investigate whether nanomaterials are capable of inhibition of differentiation in the embryonic stem cell test.
View Article and Find Full Text PDF