Publications by authors named "Margherita Betti"

This large multicenter study of 37 magnetic resonance imaging scanners aimed at characterizing, for the first time, spatial profiles of inaccuracy (namely, Δ-profiles) in apparent diffusion coefficient (ADC) values with varying acquisition plan orientation and diffusion weighting gradient direction, using a statistical approach exploiting unsupervised clustering analysis. A diffusion-weighted imaging (DWI) protocol (b-value: 0-200-400-600-800-1000 s mm) with different combinations of acquisition plan orientation (axial/sagittal/coronal) and diffusion weighting gradient direction (anterior-posterior/left-right/feet-head) was acquired on a standard water phantom. For each acquisition setup, Δ-profiles along the 3 main orthogonal directions were characterized by fitting data with a second order polynomial function ().

View Article and Find Full Text PDF

Triage is crucial for patient's management and estimation of the required intensive care unit (ICU) beds is fundamental for health systems during the COVID-19 pandemic. We assessed whether chest computed tomography (CT) of COVID-19 pneumonia has an incremental role in predicting patient's admission to ICU. We performed volumetric and texture analysis of the areas of the affected lung in CT of 115 outpatients with COVID-19 infection presenting to the emergency room with dyspnea and unresponsive hypoxyemia.

View Article and Find Full Text PDF

Purpose: The purpose of this multicenter phantom study was to exploit an innovative approach, based on an extensive acquisition protocol and unsupervised clustering analysis, in order to assess any potential bias in apparent diffusion coefficient (ADC) estimation due to different scanner characteristics. Moreover, we aimed at assessing, for the first time, any effect of acquisition plan/phase encoding direction on ADC estimation.

Methods: Water phantom acquisitions were carried out on 39 scanners.

View Article and Find Full Text PDF

Purpose: To perform a multi-centre survey on the eye lens equivalent dose absorbed by primary interventionalist during catheterization procedures, using a personal dosimeter placed close to the eye lens.

Methods: 15 different cardiologists working in 3 different centers, for a total of 5 operating rooms were enrolled. All of them were provided with a single thermoluminescent dosimeter positioned on the inner side of the temples of eyeglasses.

View Article and Find Full Text PDF

Purpose: To propose an MRI quality assurance procedure that can be used for routine controls and multi-centre comparison of different MR-scanners for quantitative diffusion-weighted imaging (DWI).

Materials And Methods: 44 MR-scanners with different field strengths (1 T, 1.5 T and 3 T) were included in the study.

View Article and Find Full Text PDF

The present study is focused on the exploitation and conversion of sulphated polysaccharides obtained from waste algal biomass into high value added material for biomedical applications. ulvan, a sulphated polysaccharide extracted from green seaweeds belonging to Ulva sp. was selected as a suitable material due to its chemical versatility and widely ascertained bioactivity.

View Article and Find Full Text PDF

Aim: The main purpose of this study is to perform a dosimetric comparison on target volumes and organs at risks (OARs) between prostate intensity modulated treatment plans (IMRT) optimized with different multileaf collimators (MLCs).

Background: The use of MLCs with a small leaf width in the IMRT optimization may improve conformity around the tumor target whilst reducing the dose to normal tissues.

Materials And Methods: Two linacs mounting MLCs with 5 and 10 mm leaf-width, respectively, implemented in Pinnacle(3) treatment planning system were used for this work.

View Article and Find Full Text PDF

Purpose: To propose a magnetic resonance imaging (MRI) quality assurance procedure that can be used for multicenter comparison of different MR scanners for quantitative diffusion-weighted imaging (DWI).

Materials And Methods: Twenty-six centers (35 MR scanners with field strengths: 1T, 1.5T, and 3T) were enrolled in the study.

View Article and Find Full Text PDF

Aim: To investigate the variation in biological effective dose (BED) produced by the uncertainty in absorbed dose and radiobiological parameters in Zevalin radioimmunotherapy.

Methods: Eight patients scheduled for treatment with standard administration of (90)Y-ibritumomab tiuxetan (Zevalin) were studied. Patient-specific pretherapy dosimetry was performed by injection of (111)In-ibritumomab tiuxetan.

View Article and Find Full Text PDF

The recent development of new gamma imagers based on scintillation array with high spatial resolution, has strongly improved the possibility of detecting sub-centimeter cancer in Scintimammography. However, Compton scattering contamination remains the main drawback since it limits the sensitivity of tumor detection. Principal component image analysis (PCA), recently introduced in scintimam nographic imaging, is a data reduction technique able to represent the radiation emitted from chest, breast healthy and damaged tissues as separated images.

View Article and Find Full Text PDF

Several efforts have been focusing on the development of detectors devoted to high solution (99m)Tc sestamibi scintimammography to improve sensitivity for non palpable lesions. To this aim new high resolution scintillation gamma camera was developed under the "Integiated Mammographic Imaging" project. The gamma camera, made by CAEN and Pol.

View Article and Find Full Text PDF

Pinhole gamma camera imaging offers the ability to obtain high resolution images from single gamma ray emitting radiotracers playing a reasonable tradeoff between very small field of view (FoV) and sensitivity. On the other hand the total spatial resolution of a pinhole imaging device is predominantly affected by the detector intrinsic spatial resolution for reduced magnification factors. To design very compact pinhole SPET scanners with very high intrinsic spatial resolution, authors investigated a miniature gamma camera based on the newly developed Hamamatsu H8500 flat panel photomultiplier.

View Article and Find Full Text PDF