Ensuring accurate patient identification is central to preventing medical errors, but it can be challenging. We implemented a bar code-based positive patient identification system for use in inpatient phlebotomy. A before-after design was used to evaluate the impact of the identification system on the frequency of mislabeled and unlabeled samples reported in our laboratory.
View Article and Find Full Text PDFOur goals were to improve the overall patient experience and optimize the blood collection process in outpatient phlebotomy using Lean principles. Elimination of non-value-added steps and modifications to operational processes resulted in increased capacity to handle workload during peak times without adding staff. The result was a reduction of average patient wait time from 21 to 5 minutes, with the goal of drawing blood samples within 10 minutes of arrival at the phlebotomy station met for 90% of patients.