Objective: Our primary objective was to determine if there was a difference in success of cardiac visualization by focused transthoracic echocardiography (TTE) location (subxiphoid, parasternal, or apical) during chest compression interruptions among cardiac arrest patients. Secondarily, we sought to determine whether there were differences in chest compression interruption times with the focused TTE locations.
Methods: We conducted a retrospective cohort study of video-recorded, adult, cardiac arrest resuscitations in a quaternary care Emergency Department from 11/2018 to 11/2023.
Background: In emergency department (ED) patients with renal impairment, troponin concentrations can be positive without myocardial ischemia. When there is clinical concern for acute coronary syndrome (ACS), guidelines recommend obtaining a delta troponin measurement to identify acute myocardial injury. However, evidence supporting the use of delta troponin to rule in or out ACS in patients with renal impairment and initial elevated troponin levels is limited.
View Article and Find Full Text PDFStudy Objective: We propose a novel method of evaluating right ventricular (RV) dysfunction in the emergency department (ED) using RV "bubble time"-the duration of time bubbles from a saline solution flush are visualized in the RV on echocardiography. The objective was to identify the optimal cutoff value for RV bubble time that differentiates patients with RV dysfunction and report on its diagnostic test characteristics.
Methods: This prospective diagnostic accuracy study enrolled a convenience sample of hemodynamically stable patients in the ED.
Background: An accurate, non-invasive measure of return of spontaneous circulation (ROSC) is needed to improve management of cardiac arrest patients.
Objectives: During a pulse check in Emergency Department (ED) cardiac arrest patients, we compared the correlation between 1) end tidal carbon dioxide (ETCO) and systolic blood pressure (SBP), and 2) Doppler ultrasound peak systolic velocity (PSV) and SBP. Additionally, we assessed the accuracy of PSV ≥ 20 cm/sec in comparison to previously suggested ETCO ≥ 20 or ≥ 25 mmHg thresholds to predict ROSC with SBP ≥ 60 mmHg.
Background: Immediate-use steam sterilization (IUSS), formerly termed "flash" sterilization, has been historically used to sterilize surgical instruments in emergency situations. Strict guidelines deter its use, as IUSS has been theorized to increase the risk of surgical site infections (SSIs), leading to increased health-care costs and poor patient outcomes. We sought to examine the association between the use of IUSS and the rate of orthopaedic SSIs.
View Article and Find Full Text PDF