The study aimed to investigate the feasibility of attenuation imaging (ATI) measurements using a linear probe on healthy volunteers and compare measurements with the conventional convex probe. Attenuation imaging measurements of the liver tissue were taken using ultrasound with a convex and a linear probe in 33 volunteers by two examining doctors, and the measurements were repeated 4-5 weeks later by one of them. The ATI values for the linear probe were in the range of the values for the convex probe for both examiners.
View Article and Find Full Text PDFThere have been studies showing attenuation imaging (ATI) with ultrasound as an approach to diagnose liver diseases such as steatosis or cirrhosis. So far, this technique has only been used on a convex probe. The goal of the study was to investigate the feasibility of ATI measurements using the linear array on a canon Aplio i800 scanner on certified phantoms.
View Article and Find Full Text PDFObjective: The aim of the work described here was to investigate the relative contribution of confounding factors on liver shear wave speed (SWS) and shear wave dispersion slope (SWDS) measurements in three certified phantoms using a Canon Aplio clinical ultrasound scanner.
Methods: A Canon Aplio i800 i-series ultrasound system (Canon Medical Systems Corporation, Otawara, Tochigi, Japan) with i8CX1 convex array (center frequency = 4 MHz) was used to examine dependencies caused by the depth, width and height of the acquisition box (AQB), the depth and size of the region of interest (ROI), the AQB angle and the pressure of the ultrasound probe on the surface of the phantom.
Results: Results revealed that depth is the most significant confounder in both SWS and SWDS measurements.
Diagnostics (Basel)
March 2023
Objectives: Measurement location and patient state can impact noninvasive liver assessment and change clinical staging in ultrasound examinations. Research into differences exists for Shear Wave Speed (SWS) and Attenuation Imaging (ATI), but not for Shear Wave Dispersion (SWD). The aim of this study is to assess the effect of breathing phase, liver lobe, and prandial state on SWS, SWD, and ATI ultrasound measurements.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
August 2022
The velocity of ultrasound longitudinal waves (speed of sound) is emerging as a valuable biomarker for a wide range of diseases, including musculoskeletal disorders. Muscles are fiber-rich tissues that exhibit anisotropic behavior, meaning that velocities vary with the wave-propagation direction. Therefore, quantifying anisotropy is essential to improve velocity estimates while providing a new metric related to muscle composition and architecture.
View Article and Find Full Text PDFThere is a growing interest in quantifying shear-wave dispersion (SWD) with ultrasound shear-wave elastography (SWE). Recent studies suggest that SWD complements shear-wave speed (SWS) in diffuse liver disease diagnosis. To accurately interpret these metrics in clinical practice, we analyzed the impact of operator-dependent acquisition parameters on SWD and SWS measurements.
View Article and Find Full Text PDFBackground: The purpose of this study was threefold: (I) to study the correlation of speed-of-sound (SoS) and shear-wave-speed (SWS) ultrasound (US) in the gastrocnemius muscle, (II) to use reproducible tissue compression to characterize tissue nonlinearity effects, and (III) to compare the potential of SoS and SWS for tissue composition assessment.
Methods: Twenty gastrocnemius muscles of 10 healthy young subjects (age range, 23-34 years, two females and eight males) were prospectively examined with both clinical SWS (GE Logiq E9, in m/s) and a prototype system that measures SoS (in m/s). A reflector was positioned opposite the US probe as a timing reference for SoS, with the muscle in between.
To compare the speed of propagation of ultrasound (US) waves (SoS) of the lower leg with the clinical reference standard computed tomography (CT) at the level of lumbar vertebra 3 (L3) for muscle loss assessment. Both calf muscles of 50 patients scheduled for an abdominal CT were prospectively examined with ultrasound. A plexiglas-reflector located on the opposite side of the probe with the calf in between was used as a timing reference for SoS (m/s).
View Article and Find Full Text PDFShort-term immobilization leads to fatty muscular degeneration, which is associated with various negative health effects. Based on literature showing very high correlations between MRI Dixon fat fraction and Speed-of-Sound (SoS), we hypothesized that we can detect short-term-immobilization-induced differences in SoS.Both calves of 10 patients with a calf cast on one side for a mean duration of 41 ± 26 days were examined in relaxed position using a standard ultrasound machine.
View Article and Find Full Text PDFBotulinum toxin type A (BTX-A) injections in masseter muscle can alleviate muscle tightness and aching pain caused by idiopathic masticatory myalgia, a subform of the myofascial pain syndrome. Yet the injection procedure (number, amount) is currently empirical. In this ex vivo study, we determined the feasibility of using contrast-free ultrasound imaging to visualize the short-term injectate propagation.
View Article and Find Full Text PDFObjectives: Skin fibrosis is a main hallmark of systemic sclerosis (SSc). Clinical assessment is done semi-quantitatively using the modified Rodnan skin score (mRSS). Objective measurements for quantifying skin fibrosis could complement the mRSS to achieve higher reproducibility.
View Article and Find Full Text PDFObjectives: To compare speed of sound (SoS) ultrasound (US) of the calves with Dixon magnetic resonance imaging (MRI) for fat content quantification.
Materials And Methods: The study was approved by the local ethics committee. Fifty calf muscles of 35 women (age range 22-81 years) prospectively underwent an US and subsequent MRI (Dixon sequence) examination as well as body weight and impedance fat measurements.
IEEE Trans Ultrason Ferroelectr Freq Control
December 2019
Tissue biomechanical properties are known to be sensitive to pathological changes. Accordingly, various techniques have been developed to estimate tissue mechanical properties. Shear-wave elastography (SWE) measures shear-wave speed (SWS) in tissues, which can be related to shear modulus.
View Article and Find Full Text PDFThe goal of the study was to investigate the quantitative impact of region of interest (ROI), software choice, muscle fiber orientation and preload tension on shear wave velocity (SWV). First, SWV was assessed in an isotropic elasticity phantom and ex vivo porcine muscle using a commercially available clinical ultrasound system. Secondly, SWV was acquired in relaxed and stretched calf muscles of healthy volunteers (dorsal extension of the talocrural joint), for both parallel and transverse probe direction to the fibers, as well as for different ROIs and software versions.
View Article and Find Full Text PDFTo investigate changes in breast density (BD) during the menstrual cycle in young women in comparison to inter-breast and -segment changes as well as reproducibility of a novel Speed-of-Sound (SoS) Ultrasound (US) method.SoS-US uses a conventional US system with a reflector and a software add-on to quantify SoS in the retro-mammillary, inner and outer segments of both breasts. Twenty healthy women (18-40 years) with regular menstrual cycles were scanned twice with two weeks in-between.
View Article and Find Full Text PDFPurpose: The aim of this study was to differentiate malignant and benign solid breast lesions with a novel ultrasound (US) technique, which measures speed of sound (SoS) using standard US transducers and intrinsic tissue reflections and scattering (speckles) as internal reference.
Materials And Methods: This prospective, institutional review board-approved, Health Insurance Portability and Accountability Act-compliant prospective comparison study was performed with prior written informed consent from 20 women. Ten women with histological proven breast cancer and 10 with fibroadenoma were measured.
Objective: Speed-of-sound (SoS) has large potential for tissue and pathology differentiation. We aim to develop a novel Ultrasound Computed Tomography (USCT) technique that can reconstruct local SoS in tissue on conventional ultrasound machines with hand-held linear arrays.
Methods: A passive reflector is placed opposite the tissue sample as an echogenic reference to measure the time-of-flight (ToF) of ultrasound wave- fronts.
Despite many uses of ultrasound, some pathologies such as breast cancer still cannot reliably be diagnosed in either conventional B-mode ultrasound imaging nor with more recent ultrasound elastography methods. Speed-of-sound (SoS) is a quantitative imaging biomarker, which is sensitive to structural changes due to pathology, and hence could facilitate diagnosis. Full-angle ultrasound computed tomography (USCT) was proposed to obtain spatially-resolved SoS images, however, its water-bath setup involves practical limitations.
View Article and Find Full Text PDFObjectives: To measure speed of sound (SoS) with a novel hand-held ultrasound technique as a quantitative indicator for muscle loss and fatty muscular degeneration.
Methods: Both calf muscles of 11 healthy, young females (mean age 29 years), and 10 elderly females (mean age 82 years) were prospectively examined with a standard ultrasound machine. A flat Plexiglas® reflector, on the opposite side of the probe with the calf in between, was used as timing reference for SoS (m/s) and ΔSoS (variation of SoS, m/s).
Objective: To evaluate measurement confounders on 2D shear wave elastography (2D-SWE) elastography of muscle.
Materials And Methods: , porcine muscle was examined with a GE LOGIQ E9 ultrasound machine with a 9 L linear (9 MHz) and C1-6 convex probe (operating at 2.5 or 6 MHz).
Objectives: To assess feasibility and diagnostic accuracy of a novel hand-held ultrasound (US) method for breast density assessment that measures the speed of sound (SoS), in comparison to the ACR mammographic (MG) categories.
Methods: ACR-MG density (a=fatty to d=extremely dense) and SoS-US were assessed in the retromamillary, inner and outer segments of 106 women by two radiographers. A conventional US system was used for SoS-US.
J Mech Behav Biomed Mater
February 2018
The facial tissue of 9 healthy volunteers (m/f; age: 23-60y) is characterized at three different locations using a procedure combining suction measurements and 18MHz ultrasound imaging. The time-dependent and multilayered nature of skin is accounted for by adopting multiple loading protocols which differ with respect to suction probe opening size and rate of tissue deformation. Over 700 suction measurements were conducted and analyzed according to location-specific mechanical and morphological characteristics.
View Article and Find Full Text PDFPurpose: To evaluate needle visibility in ultrasound under contrast mode conditions.
Materials And Methods: Needle visibility was evaluated for bevel, EchoTip and shaft of 18G Chiba biopsy needle with a 9 MHz linear probe (GE Logiq E9). Insertion angles varied between 30°(steep) and 90°(parallel to the probe surface).
This project evaluated a low-cost sponge phantom setup for its capability to teach and study A- and B-line reverberation artifacts known from lung ultrasound and to numerically simulate sound wave interaction with the phantom using a finite-difference time-domain (FDTD) model. Both A- and B-line artifacts were reproducible on B-mode ultrasound imaging as well as in the FDTD-based simulation. The phantom was found to be an easy-to-set up and economical tool for understanding, teaching, and researching A- and B-line artifacts occurring in lung ultrasound.
View Article and Find Full Text PDF