Background And Purpose: Paradoxical embolization is frequently posited as a mechanism of ischemic stroke in patients with patent foramen ovale. Several studies have suggested that the deep lower extremity and pelvic veins might be an embolic source in cryptogenic stroke (CS) patients with patent foramen ovale.
Methods: Consecutive adult patients with ischemic stroke or transient ischemic attack and a patent foramen ovale who underwent pelvic magnetic resonance venography as part of an inpatient diagnostic evaluation were included in this single-center retrospective observational study to determine pelvic and lower extremity (LE) deep venous thrombosis (DVT) prevalence in CS versus non-CS stroke subtypes.
Objective: To evaluate the contribution of iterative reconstruction on image quality of reduced-dose multidetector computed tomography of the thoracic aorta.
Methods: A torso phantom was scanned using two tube potentials (80 and 120 kVp) and five different tube currents (110, 75, 40, 20, and 10 mAs). All images were reconstructed with both filtered back projection (FBP) and iterative reconstruction.
AJR Am J Roentgenol
November 2013
Objective: The purpose of this study was intrapatient comparison of image quality and radiation dose between MDCT scans of the chest, abdomen, and pelvis obtained with attenuation-based automated kilovoltage selection and sinogram-affirmed iterative reconstruction and scans obtained with standard kilovoltage selection and a filtered backprojection image reconstruction algorithm.
Materials And Methods: One hundred one oncology patients who had undergone two chest, abdominal, and pelvis CT scans within 1 year were imaged with standard tube voltage selection of 120 kVp using a filtered backprojection reconstruction algorithm (protocol 1) and with attenuation-based automated tube voltage selection using an iterative reconstruction algorithm (protocol 2). Radiation dose parameters (volumetric CT dose index [CTDIvol], dose-length product, and effective dose) as well as image noise, signal-to-noise ratio, and contrast-to-noise ratio were compared.
Objective: To evaluate the effect of different acquisition parameters and reconstruction algorithms in lung lesions conspicuity in chest MDCT.
Methods: An anthropomorphic chest phantom containing 6 models of lung disease (ground glass opacity, bronchial polyp, solid nodule, ground glass nodule, emphysema and tree-in-bud) was scanned using 80, 100 and 120 kVp, with fixed mAs ranging from 10 to 110. The scans were reconstructed using filtered back projection (FBP) and iterative reconstruction (IR) algorithms.
Background And Objectives: Because of medical progress, life expectancy has been prolonged and the elderly population submitted to surgical procedures has been growing. Besides age-related cardiovascular changes, the prevalence of diseases, such as systemic hypertension, affect cardiovascular reserve and increase morbidity, mortality and perioperative outcomes. Electrocardiogram is useful in diagnosing previous myocardial infarction and arrhythmias.
View Article and Find Full Text PDF