Polymers (Basel)
September 2024
This in vitro study aimed to analyze the surface roughness (Ra) and color stability (ΔEab, ΔE00) following simulated mechanical brushing and to evaluate the microtensile (μTBS) of self-adhering resin flowable (SARF) to dentin. The selected materials were Constic, Yflow AS, and Tetric N flow (TNF/control). Thirty composite resin cylinders were fabricated for surface property evaluation.
View Article and Find Full Text PDFPolymers (Basel)
July 2024
The objective was to compare the color match and color stability behavior of single- and multi-shade resin-based composites (RBCs) used for direct restorations. This review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Randomized clinical trials evaluating the shade performance of single-shade RBCs in direct restorations were included.
View Article and Find Full Text PDFPolymers (Basel)
May 2024
Background: This study investigated effects of rapid high-intensity light-curing (3 s) on increasing transdentinal temperature and cell viability.
Methods: A total of 40 dentin discs (0.5 mm) obtained from human molars were prepared, included in artificial pulp chambers (4.
J Dent
February 2022
Objectives: To evaluate the effect of a glutaraldehyde-based desensitizer on the postoperative sensitivity (POS) in posterior resin composite restorations up to 12 months using a universal adhesive (Tetric N-Bond Universal) with selective enamel etching (SE) or an etch-and-rinse (ER) strategy.
Methods: Class I and class II resin composite restorations (n = 220) at least 3 mm deep were inserted in 55 subjects. The universal adhesive was applied using the SE (self-etch strategy on dentin with selective enamel etching) or the ER strategy, with or without prior application of a glutaraldehyde-based desensitizer (Gluma Desensitizer - GL) to form groups SEGL and ERGL.
Clin Oral Investig
November 2021
Objectives: This study compared the clinical performance of two bulk-fill (BF) and one conventional resin composite in a population with a high caries incidence.
Materials And Methods: A total of 138 class I and II restorations were performed and randomly divided into three groups (n = 46) with equal allocation: Filtek BF (FBF; 3M ESPE), Tetric EvoCeram BF (TBF; Ivoclar Vivadent), and control Filtek Z250 (Z250; 3M ESPE). The evaluations were performed using the USPHS and FDI criteria at baseline and after 12 and 36 months by a previously calibrated evaluator.
Eur J Dent
May 2021
Objective: This study was aimed to compare the 12-month clinical performance of two full-body bulk-fill resin composites Filtek bulk fill/3M ESPE (FBF) and Tetric EvoCeram bulk fill/Ivoclar Vivadent (TBF) and a conventional microhybrid resin composite Filtek Z250/3M ESPE (Z250) using the modified the United States Public Health Service (USPHS) and Federation Dentaire Internationale (FDI) criteria. Also, the agreement between the two evaluation criteria was evaluated at baseline and after 12 months of follow-up.
Materials And Methods: A total of 138 class I and II restorations were placed in posterior teeth (split-mouth design) of 46 volunteers following manufacturer's instructions and bonded with a self-etching bonding agent (Clear fill SE Bond/Kuraray).
Herein, the effect of different post-pressing times and pressure in two cycles of polymerization on the degree of conversion (DC) of thermally activated acrylic resin (TRRA) is analyzed to optimize the polymerization of this material. After post-pressing for 0, 6, or 12 h, polymerization was performed with or without a pressure of 60 psi (0.41 MPa) in a short (4 h) or a long (11 h) cycle, totaling 12 groups.
View Article and Find Full Text PDFBraz Oral Res
June 2018
Polymethyl methacrylate (PMMA) has been considered a suitable material for cranioplasty. However, no consensus has been reached concerning the best material for cranioplasty with regard to minimizing complications. Thus, this systematic review and meta-analysis aimed to compare the complication rates of PMMA with those of autologous bone and titanium mesh.
View Article and Find Full Text PDFThe aim of the present study was to compare the effect of pre-treating dentin with chlorhexidine, at concentrations of 0.2% and 2%, and remineralizing paste containing CPP-ACP (MI Paste - GC) on the bond strength of adhesive systems. In total, 80 slides of dentin were used.
View Article and Find Full Text PDFGen Dent
November 2016
This in vitro study sought to evaluate both the bleaching potential and changes to average surface roughness (Ra) of enamel after brushing with a dentifrice. Fifty-four enamel specimens (4 x 4 x 2 mm) were divided into 3 groups (n = 18) and treated with 1 of 3 dentifrices: 1 with calcium peroxide, and 2 without. The samples were submitted to 20,000 brushing cycles.
View Article and Find Full Text PDFBraz Dent J
December 2013
Objective: This study aimed to evaluate the progression of sealed non-cavitated dentinal occlusal caries in a randomised controlled clinical trial.
Materials And Methods: Sixty teeth with non-cavitated dentinal occlusal caries were selected in patients with a high risk for caries. Patients were randomly divided into two groups so that each group included 30 teeth.
Microsc Res Tech
November 2012
Although in-office bleaching has been proven successful for bleaching teeth, controversy exists from morphological alterations in enamel morphology due to mineral loss and tooth sensitivity. This preliminary study aimed to evaluate the efficacy of a novel in-office tooth bleaching technique modified with a casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) paste (MI paste-MI) and its effect on the enamel morphology and tooth sensitivity. Three patients received a 35% hydrogen peroxide (Whiteness HP-HP) dental bleaching system.
View Article and Find Full Text PDFActa Odontol Scand
October 2013
Aim: This study aimed to evaluate the effect of pre-heated composite restoratives on the shear bond strength (SBS) of orthodontic brackets.
Methods: The following materials were tested: a microhybrid composite restorative (Filtek Z250), two nanofilled composite restoratives (Filtek Z350 and NT Premium), a nanohybrid composite restorative (Brilliant) and a conventional orthodontic adhesive (Transbond XT). All materials were stored for 1 h in the incubator either at 25°C (room temperature simulation) or 60°C before bonding 100 orthodontic brackets on bovine lower incisors (n = 10).
This randomized trial evaluated the 12-month clinical performance of nanofill, a nanohybrid, and a microhybrid composite in restorations in occlusal cavities of posterior teeth. This study utilized 41 patients, each of whom had three molars affected by primary caries or the need to replace restorations. All restorations were performed in accordance with the manufacturer's recommendations and evaluated in accordance with U.
View Article and Find Full Text PDFWe evaluated the influence of photoactivation method and hydrophobic resin (HR) application on the marginal and internal adaptation, hardness (KHN), and crosslink density (CLD) of a resin-based fissure sealant. Model fissures were created in bovine enamel fragments (n = 10) and sealed using one of the following protocols: no adhesive system + photoactivation of the sealant using continuous light (CL), no adhesive system + photoactivation of the sealant using the soft-start method (SS), HR + CL, or HR + SS. Marginal and internal gaps and KHN were assessed after storage in water for 24 h.
View Article and Find Full Text PDFActa Odontol Scand
January 2013
Objective: This study aimed to evaluate the push-out bond strength of dimethacrylate (Clearfil SE Bond/Filtek Z250; and Adper SE Plus/Filtek Z250) and silorane-based (Filtek P90 adhesive system/Filtek P90 composite resin) restorative systems following selective dentin pre-treatment with a CPP-ACP-containing paste (MI Paste).
Materials And Methods: Sixty bovine incisors were utilized. The buccal surface was wet-ground to obtain a flat dentin area.
This study evaluated the effect of five methods of solvent volatilization on the degree of conversion (DC) of nine one-bottle adhesive systems using Fourier transform infrared/attenuated total reflectance (FTIR/ATR) analysis. Nine adhesives were tested: Adper Single Bond 2 (SB), Adper Easy One (EO), One Up Bond F Plus (OUP), One Coat Bond SL (OC), XP Bond (XP), Ambar (AM), Natural Bond (NB), GO, and Stae. The adhesive systems were applied to a zinc-selenide pellet and 1) cured without solvent volatilization, 2) left undisturbed for 10 seconds before curing, 3) left undisturbed for 60 seconds before curing, 4) air-dried with an air stream for 10 seconds before curing, and 5) air-dried with an air stream for 60 seconds before curing.
View Article and Find Full Text PDFActa Odontol Scand
January 2013
Aim: This study aimed to characterize the morphology of filler particles and to analyze the effect of shortened and extended photoactivation times on hardness (VHN) and cross-link density (CLD) of resin-based low-viscosity materials.
Methods: Sixteen commercially available materials were tested: four fissure sealants (Alpha Seal, Fluroshield Yellowed, Bioseal and Fluroshield White) and 12 flowable composites (Opallis T, Permaflo T, Opallis A2, Natural Flow A2, Master Flow A2, Permaflo A2, Filtek Z350 A2, Natural Flow O, Master Flow OA2, Opallis OA3.5, Filtek Z350 OA3, Opallis OP) at six curing times (10 s, 20 s, 30 s, 40 s, 50 s and 60 s).
Objectives: To analyze marginal integrity of resin composites dental restorations using optical coherence tomography (OCT).
Methods: Thirty extracted human premolars had occlusal cavities prepared and were randomly divided according to the restorative systems evaluated: Filtek P90™/P90 Adhesive System™, Filtek Z350™, and Filtek Z250™/Single Bond™ (3M/ESPE). The teeth were then stored in the dark for 24h in 0.
Objectives: The purpose of this study was to evaluate polymerization shrinkage of resin composites using a coordinate measuring machine, optical coherence tomography and a more widely known method, such as Archimedes Principle. Two null hypothesis were tested: (1) there are no differences between the materials tested; (2) there are no differences between the methods used for polymerization shrinkage measurements.
Methods: Polymerization shrinkage of seven resin-based dental composites (Filtek Z250™, Filtek Z350™, Filtek P90™/3M ESPE, Esthet-X™, TPH Spectrum™/Dentsply 4 Seasons™, Tetric Ceram™/Ivoclar-Vivadent) was measured.
The aim of this study was to evaluate the influence of time of application of antioxidant agents on the bond strength to bovine enamel after bleaching by light emitting diode. Twenty two bovine incisors were used, on which the vestibular surfaces were flattened and divided into four experimental groups (n = 15) according to each antioxidant agent, with two groups each, varying the application time of 1 or 10 minutes, all submitted to the same whitening agent (Lase Peroxide) and the control group was only restored. The other groups were treated with antioxidant agents before the restorative procedure using the adhesive system All Bond 3 and resin Filtek Z-350.
View Article and Find Full Text PDFThis study evaluates the margin of a nanofill, a nanohybrid, and a conventional microhybrid composite in restorations in occlusal cavities of posterior teeth after 12 months. Forty-one patients, each with three molars affected by primary caries or the need to replace restorations, participated in this research. The teeth were restored with a nanofill (Filtek Z350), a nanohybrid (Esthet-X), and a microhybrid as a control (Filtek Z250).
View Article and Find Full Text PDFObjectives: The aim of this study was to evaluate, in vitro, the potential cytotoxicity of dentinal adhesives on alveolar macrophages of Wistar rats, after diffusion through dentin.
Methods: The cytotoxicity of adhesives [single bond plus (SB), clearfil SE bond (CF) and Xeno V (XE)] applied to the occlusal surface of human dentin disks adapted to a dentin barrier test device were analyzed. The sets placed on a monolayer of cells were incubated for 24, 48 and 72h.