Iatrogenic arterial injury is an infrequent but limb-threatening complication of total knee arthroplasty (TKA). Open surgical reconstruction may not always be feasible or optimal, particularly in patients who have recently just undergone complex TKA procedures. In this report, we describe the treatment of a patient who developed popliteal artery occlusion following a complex TKA procedure performed the previous day.
View Article and Find Full Text PDFBackground: The aim of this study is to evaluate the safety and feasibility of the AngioJet™ device in the endovascular treatment of visceral ischemia with stenotic or occlusive lesions.
Methods: Retrospective analysis of patients treated for visceral artery occlusion with thrombectomy using the AngioJet™ (Boston Scientific, MA, USA). Inclusion criteria: patients with stenotic or occluding lesion in visceral arteries including renal and mesenteric arteries, who received endovascular treatment with AngioJet™.
Purpose: To evaluate retrospectively the 2-year outcomes of the Gore Excluder Iliac Branch Endoprosthesis (IBE) in patients with and without coexisting hypogastric artery (HA) aneurysms in a large contemporary multicentric European experience using dedicated bridging devices.
Methods: The study included all consecutive patients treated at participating institutions with the Gore Excluder IBE device who received a covered stent (i.e.
Objective: We present the case of a 58-year-old male patient referred to our department from a smaller facility for further evaluation and treatment strategy regarding the choice between open or endovascular surgery. The patient was diagnosed with a 6 cm asymptomatic juxtarenal aortic aneurysm and a 5 mm diameter accessory renal artery (ARA) supplying the lower half of left kidney. Further diagnostic assessments indicated that the left ARA was perfusing over 40% of the left kidney.
View Article and Find Full Text PDFGastric cancer is the fifth most common and fourth deadliest cancer worldwide, with a bleak 5-year survival rate of about 20%. Despite significant research into its pathobiology, prognostic predictability remains insufficient due to pathologists' heavy workloads and the potential for diagnostic errors. Consequently, there is a pressing need for automated and precise histopathological diagnostic tools.
View Article and Find Full Text PDFPurpose: This technical note presents a case of a patient with a failed Nellix device (Endologix, Irvine, Calif) who was not deemed fit for open conversion. Our planned approach for repair involved an endovascular procedure utilizing a custom-made branched device.
Technique: An endovascular repair was performed via a custom-made four outer branched device in conjunction with a custom-made bifurcated graft featuring inverted limbs (Cook Inc.
Background: The aim of this study was to evaluate the early results of the CE-marked standardized device combination consisting of Endurant and the Radiant chimney graft (En-ChEVAR) for the treatment of juxtarenal aortic aneurysms.
Methods: We analyzed multicentric non-industry sponsored case series evaluating the EnChEVAR technique for patients treated between December 2022 and February 2024. Clinical, perioperative procedure-related and radiological data were collected.
Objectives: While the link between carotid plaque composition and cerebrovascular vascular (CVE) events is recognized, the role of calcium configuration remains unclear. This study aimed to develop and validate a CT angiography (CTA)-based machine learning (ML) model that uses carotid plaques 6-type calcium grading, and clinical parameters to identify CVE patients with bilateral plaques.
Material And Methods: We conducted a multicenter, retrospective diagnostic study (March 2013-May 2020) approved by the institutional review board.
Objectives: Axillary artery aneurysms in children are rare and multifactorial. The presenting clinical picture can range from an incidental discovery to threatening symptoms, including loss of extremity function. With the present study we aim to give a comprehensive review of the existing literature focusing on the etiology and management of this rare but threatening pathology.
View Article and Find Full Text PDFThoracic endovascular aortic repair (TEVAR) is a widespread minimally invasive procedure prevalently used to treat thoracic aortic pathologies. However, when the left subclavian artery (LSA) is involved in the pathology, a more complex surgical approach is required to guarantee the perfusion of the vertebral and brachial arteries. In fact, coverage of the LSA has been proven to be associated with a higher risk of stroke, spinal cord ischemia, and arm ischemia.
View Article and Find Full Text PDFObjective: This post-market multicenter registry aimed to evaluate the safety and performance of the GORE VIABAHN VBX balloon expandable endoprosthesis (VBX stent) implanted in peripheral vessels. In this subgroup analysis, we assessed the outcomes of the VBX stent as a bridging stent graft for visceral vessels during branched endovascular aortic repair at 1 year.
Methods: A single cohort from a prospective, multicenter, observational, 16-site European registry.
Objective: To evaluate in vitro the performance of in vivo published covered or bare metal chimney stents (ChSs) in combination with the Endurant II abdominal endograft (Medtronic) as the only CE approved main graft (MG) in the treatment of juxtarenal abdominal aortic aneurysms with the chimney endovascular aneurysm repair (chEVAR) technique.
Methods: Bench top experimental study. A silicon flow model with adjustable physiological simulating conditions and patient based anatomy was used to test nine different MG-ChS combinations: Advanta V12 (Getinge); BeGraft (Bentley); VBX (Gore & Associates Inc.
Objectives: Carbon dioxide (CO) angiography for endovascular aortic repair (CO-EVAR) is used to treat abdominal aortic aneurysms (AAAs), especially in patients with chronic kidney disease or allergy to iodinated contrast medium (ICM). However, some technical issues regarding the visualization of the lowest renal artery (LoRA) and the best quality image through angiographies performed from pigtail or introducer sheath are still unsolved. The aim of this study was to analyze different steps of CO-EVAR to create an operative standardized protocol.
View Article and Find Full Text PDFJ Cardiovasc Surg (Torino)
February 2022
Introduction: Surgical endarterectomy represents the gold standard for the treatment of atherosclerotic lesions of the groin vessels. Endovascular treatment such as atherectomy with or without drug coated angioplasty (DCA) of the so called no stenting zones, i.e.
View Article and Find Full Text PDFBackground: Thoracic endovascular aortic repair (TEVAR) can be challenging in cases involving the aortic arch and the visceral segment. We report our initial experience with fenestrated TEVAR (f-TEVAR) for thoracic aortic disease involving aortic branches using physician-modified stent grafts (PMSGs).
Methods: Between February 2019 and November 2020 nine patients were treated with a PMSG.
Background: Frozen elephant trunk (FET) is an established approach to reduce late complications of type A aortic dissection (AADA) by diminishing false lumen perfusion. Currently, surface size of aortic lumina are evaluated using Computed tomography (CT). However, this 2D method is prone to error as it evaluates dissection progression slice by slice.
View Article and Find Full Text PDFCardiovascular disease remains the most frequent cause of death worldwide. Atherosclerosis, an underlying cause of cardiovascular disease, is an inflammatory disorder associated with endothelial dysfunction. The endothelin system plays a crucial role in the pathogenesis of endothelial dysfunction and is involved in the development of atherosclerosis.
View Article and Find Full Text PDFBackground: Aim of this study was to compare the modifications of systemic blood pressure in patients with subacute type b aortic dissection (TBAD) and refractory (rHTN) and non-refractory arterial hypertension (N-rHTN) treated by thoracic endovascular aortic repair (TEVAR).
Methods: Patients were divided into two groups, rHTN defined as blood pressure >140/90 mmHg with ≥5 antihypertensive drugs and patients with N-rHTN. Primary endpoint was the variation of mean systolic, diastolic and overall pressure (MSP, MDP and MAP) before and after antihypertensive treatment or TEVAR.
Objective: To compare the efficacy and safety as well as associated image quality of catheter-directed CT angiography (CCTA) with a low dose of iodine contrast agent compared to intravenous CTA in patients undergoing endovascular aortic aneurysm repair (EVAR).
Methods: Retrospective data analysis of 92 patients undergoing EVAR between January 2009 and December 2017 was performed. Patients were divided in two groups; those receiving CTA (n = 59) after intravenous contrast agent application and those receiving CCTA (n = 33) via an intraarterial catheter placed in the descending aorta.