Objectives: Finite element modeling was adopted to quantitatively compare, for the first time and on a patient-specific basis, the biomechanical effects of a broad spectrum of different neochordal implantation techniques for the repair of isolated posterior mitral leaflet prolapse.
Methods: Cardiac magnetic resonance images were acquired from 4 patients undergoing surgery. A patient-specific 3-dimensional model of the mitral apparatus and the motion of the annulus and papillary muscles were reconstructed.
Purpose: Cusp extension technique (CET) is a reparative surgical procedure for restoring aortic valve function by suturing patches to the compromised native leaflets. Its outcomes are strongly dependent on the ability of the surgeon. We proposed and tested a novel approach on an in vitro model, aimed at standardizing and simplifying the surgical procedure.
View Article and Find Full Text PDFNumerical modeling can provide detailed and quantitative information on aortic root (AR) biomechanics, improving the understanding of AR complex pathophysiology and supporting the development of more effective clinical treatments. From this standpoint, fluid-structure interaction (FSI) models are currently the most exhaustive and potentially realistic computational tools. However, AR FSI modeling is extremely challenging and computationally expensive, due to the explicit simulation of coupled AR fluid dynamics and structural response, while accounting for complex morphological and mechanical features.
View Article and Find Full Text PDFRecent computational methods enabling patient-specific simulations of native and prosthetic heart valves are reviewed. Emphasis is placed on two critical components of such methods: (1) anatomically realistic finite element models for simulating the structural dynamics of heart valves; and (2) fluid structure interaction methods for simulating the performance of heart valves in a patient-specific beating left ventricle. It is shown that the significant progress achieved in both fronts paves the way toward clinically relevant computational models that can simulate the performance of a range of heart valves, native and prosthetic, in a patient-specific left heart environment.
View Article and Find Full Text PDFThe onset of thromboembolic phenomena in blood oxygenators, even in the presence of adequate anticoagulant strategies, is a relevant concern during extracorporeal circulation (ECC). For this reason, the evaluation of the thrombogenic potential associated with extracorporeal membrane oxygenators should play a critical role into the preclinical design process of these devices. This study extends the use of computational fluid dynamics simulations to guide the hemodynamic design optimization of oxygenators and evaluate their thrombogenic potential during ECC.
View Article and Find Full Text PDFOver the last twenty years major advancements have taken place in the design of medical devices and personalized therapies. They have paralleled the impressive evolution of three-dimensional, non invasive, medical imaging techniques and have been continuously fuelled by increasing computing power and the emergence of novel and sophisticated software tools. This paper aims to showcase a number of major contributions to the advancements of modeling of surgical and interventional procedures and to the design of life support systems.
View Article and Find Full Text PDFThe anterior mitral leaflet (AML) is a thin membrane that withstands high left ventricular (LV) pressure pulses 100,000 times per day. The presence of contractile cells determines AML in vivo stiffness and complex geometry. Until recently, mitral valve finite element (FE) models have neglected both of these aspects.
View Article and Find Full Text PDFThe incomplete efficacy of current surgical repair procedures of the tricuspid valve (TV) demands a deeper comprehension of the physiological TV biomechanics. To this purpose, computational models can provide quantitative insight into TV biomechanical response and allow analysing the role of each TV substructure. We present here a three-dimensional finite element model of the tricuspid valve that takes into account most of its peculiar features.
View Article and Find Full Text PDFFinite element modeling represents an established method for the comprehension of the mitral function and for the simulation of interesting clinical scenarios. However, current models still do not include all the key aspects of the real system. We implemented a new structural finite element model that considers (i) an accurate morphological description of the valve, (ii) a description of the tissues' mechanical properties that accounts for anisotropy and nonlinearity, and (iii) dynamic boundary conditions that mimic annulus and papillary muscles' contraction.
View Article and Find Full Text PDF